Schedule Viewer
Last schedule upload: D3-R25005-00-RPL06 — 6139 activities — 04/16/2026 08:19 AM CT
RPL10 - GC LIVE SCHEDULE - Data Date 20260412.xer
· Uploaded Apr 16, 2026 12:51 PM
· 8408 activities
Experimental
Auto-populate checklist dates from schedule:
100
Activities Shown
0
Completed
0
In Progress
4
Critical
| Activity ID | Activity Name | WBS | Status | Start | Finish | Dur (d) | Rem (d) | % Comp | Float (d) |
|---|---|---|---|---|---|---|---|---|---|
RPL.CM.D.N5670.XR |
Smalling Repave (LA 183 to Jaggers) | Logistics - Off-Site Receive XREF Milsetones | Not Started | 04/13/26 | 04/13/26 | 0.0 | 0.0 |
|
162.5 |
RPL.CM.D.N5690.XR |
Bridge at LA 583 ( META GIVE MILESTONE) | Logistics - Off-Site Receive XREF Milsetones | Not Started | 04/13/26 | 04/13/26 | 0.0 | 0.0 |
|
490.0 |
RPL.CM.D.N5695.XR |
LA 854 - (Donahue Rd - LA183) Repaving / Overlay | Logistics - Off-Site Receive XREF Milsetones | Not Started | 04/13/26 | 04/13/26 | 0.0 | 0.0 |
|
1991.2 |
RPL.GF.D.N0110.XR |
2 of 4 Fiber Pulls Complete (CAV1/4) MMH to GS.EF1/ Prod.EF1F | Connectivity (XREFs) | Not Started | 04/13/26 | 04/13/26 | 0.0 | 0.0 |
|
191.2 |
RPL.GF.D.N0120.XR |
4 of 4 Fiber Pulls Complete CAV2/3 to GS.EF2/ Prod.EF2B | Connectivity (XREFs) | Not Started | 04/13/26 | 04/13/26 | 0.0 | 0.0 |
|
223.8 |
RPL.GF.D.N0261.XR |
GS.IDF Hut 10-Way Install Complete (03, 04, 08, 09, 10) | Connectivity (XREFs) | Not Started | 04/13/26 | 04/13/26 | 0.0 | 0.0 |
|
233.8 |
RPL.GF.D.N0262.XR |
GS.IDF Hut 10-Way Install Complete (01, 02, 06, 07) | Connectivity (XREFs) | Not Started | 04/13/26 | 04/13/26 | 0.0 | 0.0 |
|
48.8 |
RPL.GF.D.N0263.XR |
GS.IDF Hut 10-Way Install Complete (11, 12, 13, 05) | Connectivity (XREFs) | Not Started | 04/13/26 | 04/13/26 | 0.0 | 0.0 |
|
28.8 |
RPL.GF.D.N0520.XR |
Radio Tower(s) Available for DAS/PS - SSB, NWS1, NWS2, EF1, EF2 RPL10 ( WP3B - Successor) - Commissoning affect? | Connectivity (XREFs) | Not Started | 04/13/26 | 04/13/26 | 0.0 | 0.0 |
|
106.2 |
RPL.GF.D.N0530.XR |
Radio Tower(s) Available for DAS/PS - NWS3, NWS4 (WP3B-Successor) - Commissoning affect? | Connectivity (XREFs) | Not Started | 04/13/26 | 04/13/26 | 0.0 | 0.0 |
|
106.2 |
RPL.GF.D.N0540.XR |
GS Fiber Pulls, Test & Term Complete - NWB RPL 10 to iBOS (META's Ware House logistics) | Connectivity (XREFs) | Not Started | 04/13/26 | 04/13/26 | 0.0 | 0.0 |
|
223.8 |
RPL.GF.D.N0550.XR |
GS Fiber Pulls, Test & Term Complete - NWB RPL 10 to Admin Building | Connectivity (XREFs) | Not Started | 04/13/26 | 04/13/26 | 0.0 | 0.0 |
|
223.8 |
RPL.GF.D.N0560.XR |
GS Fiber Pulls, Test & Term Complete - NWB RPL 10 to GH1 (Guard House) | Connectivity (XREFs) | Not Started | 04/13/26 | 04/13/26 | 0.0 | 0.0 |
|
223.8 |
RPL.GF.D.N0570.XR |
GS Fiber Pulls, Test & Term Complete - NWB RPL 10 to GH2 (Guard House) | Connectivity (XREFs) | Not Started | 04/13/26 | 04/13/26 | 0.0 | 0.0 |
|
223.8 |
RPL.GF.D.N0580.XR |
GS Fiber Pulls, Test & Term Complete - NWB RPL 10 to GH3 (Guard House) | Connectivity (XREFs) | Not Started | 04/13/26 | 04/13/26 | 0.0 | 0.0 |
|
223.8 |
RPL10.EY.EF1.01620 |
RPL10.EY.EF1 - Install RPL-1 FSP Columns Cap Erect Shoring & Decking & F/R/P | Fiber Support Platform - RPL-1 | Not Started | 04/13/26 | 04/20/26 | 7.5 | 7.5 |
|
203.8 |
RPL10.EY.ENDC.01250 |
RPL10.EY.End - Install Temp Conditioning Units | OFE | Not Started | 04/13/26 | 04/13/26 | 1.2 | 1.2 |
|
103.8 |
RPL10.EY.NS2.01210 |
RPL10.EY.NS2 - HAC Prefab prior to install | Tent and Temp Conditions | Not Started | 04/13/26 | 04/20/26 | 7.5 | 7.5 |
|
-27.5 |
RPL10.EY.NS2.01250 |
RPL10.EY.NS2 - Install Electrical Tie-ins (include penetration detail) | Tie-ins | Not Started | 04/13/26 | 04/24/26 | 12.5 | 12.5 |
|
40.0 |
RPL10.EY.NS2.01260 |
RPL10.EY.NS2 - Tie-ins - WBS Summary | Tie-ins | Not Started | 04/13/26 | 06/03/26 | 46.2 | 46.2 |
|
66.2 |
RPL10.EY.SSB.01160 |
RPL10.EY.SSB - Install Electrical Tie-ins (include penetration detail) | Tie-ins | Not Started | 04/13/26 | 05/08/26 | 25.0 | 25.0 |
|
23.8 |
RPL10.INT.EF1.01210 |
RPL10.Interior.EF1 - Tie-ins - WBS Summary | Tie-Ins | Not Started | 04/13/26 | 07/24/26 | 91.2 | 91.2 |
|
158.8 |
RPL10.INT.EF1.01400 |
RPL10.Interior.EF1 - Tie-ins - EF1 East - WBS Summary | East EF-1 | Not Started | 04/13/26 | 06/15/26 | 56.2 | 56.2 |
|
187.5 |
RPL10.INT.EF1.01435 |
RPL10.Interior.EF1 - EF1 East - Install Wall Mounted Ladder Racks on Full Height EF Walls | East EF-1 | Not Started | 04/13/26 | 04/17/26 | 6.2 | 6.2 |
|
231.2 |
RPL10.INT.EF1.01750 |
RPL10.Interior.EF1 - Piping Tie-Ins to FW Loop (From MES Skids) | Tie-Ins | Not Started | 04/13/26 | 04/17/26 | 6.2 | 6.2 |
|
131.2 |
RPL10.INT.EF2.01210 |
RPL10.Interior.EF2 - Tie-ins - WBS Summary | Tie-Ins | Not Started | 04/13/26 | 08/11/26 | 106.2 | 106.2 |
|
156.2 |
RPL10.INT.EF2.01810 |
RPL10.Interior.EF2 - Piping Tie-Ins to FW Loop (From MES Skids) | Tie-Ins | Not Started | 04/13/26 | 04/17/26 | 6.2 | 6.2 |
|
160.0 |
RPL10.INT.ENDC.01130 |
RPL10.Interior.End-Corridor - Install Fitout (Restroom, Janitor, Fire Riser, Humidifier) - WBS Summary | Fit out | Not Started | 04/13/26 | 04/13/26 | 0.0 | 0.0 |
|
0.0 |
RPL10.INT.NS1.01225 |
RPL10.Interior.NS1 - Control Fault Domain 6 SQ1.1 - Install Duct (MES Side) | Remaining Tie-ins post Mech Side Aisle install | Not Started | 04/13/26 | 05/08/26 | 25.0 | 25.0 |
|
38.8 |
RPL10.INT.NS1.01230 |
RPL10.Interior.NS1 - Control Fault Domain 6 SQ1.1 - Install Vesda / FA | Remaining Tie-ins post Mech Side Aisle install | Not Started | 04/13/26 | 05/08/26 | 25.0 | 25.0 |
|
52.5 |
RPL10.INT.NS1.01240 |
RPL10.Interior.NS1 - Control Fault Domain 6 SQ1.1 - Install TW | Remaining Tie-ins post Mech Side Aisle install | Not Started | 04/13/26 | 05/08/26 | 25.0 | 25.0 |
|
38.8 |
RPL10.INT.NS1.01310 |
RPL10.Interior.NS1 - Control Fault Domain 6 SQ1.1 - Install LV Side Aisle HAC Busway | LV Side Tie-ins | Not Started | 04/13/26 | 04/17/26 | 6.2 | 6.2 |
|
51.2 |
RPL10.INT.NS1.01460 |
RPL10.Interior.NS1 - Control Fault Domain 5 SQ2.1 - Install LV Side Aisle HAC Busway | LV Side Tie-ins | Not Started | 04/13/26 | 04/16/26 | 5.0 | 5.0 |
|
66.2 |
RPL10.INT.NS1.01490 |
RPL10.Interior.NS1 - Control Fault Domain 4 SQ3.1 - Install Duct (LV Side) | LV Side Tie-ins | Not Started | 04/13/26 | 04/16/26 | 5.0 | 5.0 |
|
71.2 |
RPL10.INT.NS1.01520 |
RPL10.Interior.NS1 - Tie-ins - Control Fault Domain 4 SQ3.1 (including IDF) - WBS Summary | Tie-Ins NS1 Control Fault Domain 4 | Not Started | 04/13/26 | 07/24/26 | 91.2 | 91.2 |
|
23.8 |
RPL10.INT.NS1.02120 |
RPL10.Interior.NS1 - Control Fault Domain 6 SQ1.1 - Install FW | Remaining Tie-ins post Mech Side Aisle install | Not Started | 04/13/26 | 05/08/26 | 25.0 | 25.0 |
|
38.8 |
RPL10.INT.NS3.02340 |
RPL10.Interior.NS3 - Priority - Install Electrical (Exterior Drywall mounted Branch) | OverHead | Not Started | 04/13/26 | 04/17/26 | 6.2 | 6.2 |
|
153.8 |
RPL10.INT.NS4.02340 |
RPL10.Interior.NS4 - Priority - Install Electrical (Exterior Drywall mounted Branch) | OverHead | Not Started | 04/13/26 | 04/17/26 | 6.2 | 6.2 |
|
133.8 |
RPL10.INT.SSB.03320 |
RPL10.Interior.SSB - BoW - Install Fire Safing/ Seal all Penetrations (Lowside space) | Balance of Walls and OverHead | Not Started | 04/13/26 | 04/17/26 | 6.2 | 6.2 |
|
198.8 |
RPL10.MCUP.LP1.1780 |
RPL10.MCUP.Loop 1 - Tie-in EPMS #5 | Tie-Ins EPMS | Not Started | 04/13/26 | 04/20/26 | 7.5 | 7.5 |
|
22.5 |
RPL10.MCUP.LP1.1800 |
RPL10.MCUP.Loop 1 - Tie-in BMS #5 | Tie-Ins BMS | Not Started | 04/13/26 | 04/21/26 | 8.8 | 8.8 |
|
22.5 |
RPL10.MCUP.LP1.1840 |
RPL10.MCUP.Loop 1 - Install Sleeves MEPL | Hardscape and Landscape | Not Started | 04/13/26 | 04/17/26 | 6.2 | 6.2 |
|
471.2 |
RPL10.MCUP.LP1.1980 |
RPL10.MCUP.Loop 1 - Tie-in Mechanical #7 WBS Summary | Tie-in Mechanical #7 | Not Started | 04/13/26 | 04/15/26 | 3.8 | 3.8 |
|
23.8 |
RPL10.MCUP.LP1.2000 |
RPL10.MCUP.Loop 1 - Install Lighting | Hardscape and Landscape | Not Started | 04/13/26 | 04/24/26 | 12.5 | 12.5 |
|
496.2 |
RPL10.MCUP.LP1.2040 |
RPL10.MCUP.Loop 1 - Install Mcup Paving *Start 04/10 | Hardscape and Landscape | Not Started | 04/13/26 | 05/01/26 | 18.8 | 18.8 |
|
490.0 |
RPL10.MCUP.LP1.2700 |
RPL10.MCUP.Loop 1 - Facility Water Tie-in Mechanical #7 | Tie-in Mechanical #7 | Not Started | 04/13/26 | 04/15/26 | 3.8 | 3.8 |
|
23.8 |
RPL10.MCUP.LP1.2720 |
RPL10.MCUP.Loop 1 - Condenser Water Tie-in Mechanical #7 | Tie-in Mechanical #7 | Not Started | 04/13/26 | 04/15/26 | 3.8 | 3.8 |
|
23.8 |
RPL10.MCUP.LP2.2560 |
RPL10.MCUP.Loop 2 - Set Remaining Facility water piping rack with All Racks Welding | OFE | Not Started | 04/13/26 | 04/24/26 | 12.5 | 12.5 |
|
130.0 |
RPL10.OFCI.4000 |
OFCI - Delivery ROJ: FE Fiber for CFD NS1.6 (ROJ ) (RVCD ) | NS1 | Not Started | 04/13/26 | 05/01/26 | 18.8 | 18.8 |
|
61.2 |
RPL10.OFCI.6840 |
OFCI - Delivery ROJ: FE Fiber for CFD NS1.5 (ROJ ) (RVCD ) | NS1 | Not Started | 04/13/26 | 05/01/26 | 18.8 | 18.8 |
|
68.8 |
RPL10.SSB.BB.1000 |
RPL10.Ext.Build Back.SSB - Exterior Leave Out #5 ( East SSB Area) WBS Summary | Build Back Exterior Leave Out Wall #5 (East SSB) | Not Started | 04/13/26 | 06/05/26 | 48.8 | 48.8 |
|
441.2 |
RPL10.SSB.BB.1140 |
RPL10.Ext.Build Back.SSB - LO #5 - F/R/P Stem wall | Build Back Exterior Leave Out Wall #5 (East SSB) | Not Started | 04/13/26 | 04/15/26 | 3.8 | 3.8 |
|
161.2 |
RPL10.SSBC.BB.1440 |
RPL10.Int.Build Back.SSB-Corr - Interior Leave Out (SSB Corridor) #2, #3, #4 WBS Summary | Build Back Interior Leave Out Wall #2 #3 #4 (SSB Corr) | Not Started | 04/13/26 | 06/02/26 | 45.0 | 45.0 |
|
183.8 |
RPL10.SSBC.BB.1480 |
RPL10.Int.Build Back.SSB-Corr - LO #2,3,4 - MEPF - In Wall, OH, Lowside, Lights | Build Back Interior Leave Out Wall #2 #3 #4 (SSB Corr) | Not Started | 04/13/26 | 05/08/26 | 25.0 | 25.0 |
|
183.8 |
RPL10.WP2.01000 |
RPL10.Conn SSB - Install GS Cabling Pull/Term/Test (GSMDF Cross Connects) (2x GSMDF) ~120 LF | WP2 (GS/CARRIER/SFZ - INF, CAB [ISP/OSP], NET) | Not Started | 04/13/26 | 05/22/26 | 37.5 | 37.5 |
|
68.8 |
RPL10.WP2.01160 |
RPL10.Conn IDF Huts - (GSMDF to GSIDF) EF1 NE1 WBS Summary | GSIDFNE1 | Not Started | 04/13/26 | 05/18/26 | 32.5 | 32.5 |
|
488.8 |
RPL10.WP2.EF1.1020 |
RPL10.Conn GS.EF1 Install Cabling (Pull, Splice & Terminate) | Cabling | Not Started | 04/13/26 | 04/16/26 | 5.0 | 5.0 |
|
223.8 |
RPL10.WP2.EF1.1160 |
RPL10.Conn GS.EF1 Install Cabling for Path1 from (CAV 1/4) MMH to GS.EF (Pull, Splice & Terminate) | Cabling | Not Started | 04/13/26 | 04/16/26 | 5.0 | 5.0 |
|
193.8 |
RPL10.WP2.EF2.1020 |
RPL10.Conn GS.EF2 Install Cabling (Pull, Splice & Terminate) | Cabling | Not Started | 04/13/26 | 04/16/26 | 5.0 | 5.0 |
|
223.8 |
RPL10.WP2.EF2.1040 |
RPL10.Conn GS.EF2 Install Cabling for Path1 from (CAV 1/4) MMH to GS.EF (Pull, Splice & Terminate) | Cabling | Not Started | 04/13/26 | 04/16/26 | 5.0 | 5.0 |
|
193.8 |
RPL10.WP2.GSIDF.1160 |
RPL10.Conn GSIDFNE1 Install Infrastructure (Racks, Waterfalls etc.) | Infrastructure | Not Started | 04/13/26 | 04/17/26 | 6.2 | 6.2 |
|
161.2 |
RPL10.WP2.GSIDF.1300 |
RPL10.Conn IDF Huts - (GSMDF to GSIDF) NS1 N13 WBS Summary | GSIDFN13 | Not Started | 04/13/26 | 05/12/26 | 27.5 | 27.5 |
|
235.0 |
RPL10.WP2.GSIDF.1320 |
RPL10.Conn GSIDFN13 Install Infrastructure (Racks, Waterfalls etc.) | Infrastructure | Not Started | 04/13/26 | 04/17/26 | 6.2 | 6.2 |
|
75.0 |
RPL10.WP2.GSIDF.1440 |
RPL10.Conn IDF Huts - (GSMDF to GSIDF) NS2 N23 WBS Summary | GSIDFN23 | Not Started | 04/13/26 | 05/12/26 | 27.5 | 27.5 |
|
235.0 |
RPL10.WP2.GSIDF.1460 |
RPL10.Conn GSIDFN23 Install Infrastructure (Racks, Waterfalls etc.) | Infrastructure | Not Started | 04/13/26 | 04/17/26 | 6.2 | 6.2 |
|
78.8 |
RPL10.WP2.GSIDF.1520 |
RPL10.Conn IDF Huts - (GSMDF to GSIDF) NS4 N41 WBS Summary | GSIDFN41 | Not Started | 04/13/26 | 05/19/26 | 33.8 | 33.8 |
|
312.5 |
RPL10.WP2.GSIDF.1540 |
RPL10.Conn GSIDFN41 Set Infrastructure (Racks, Waterfalls etc.) | Infrastructure | Not Started | 04/13/26 | 04/17/26 | 6.2 | 6.2 |
|
201.2 |
RPL10.WP2.GSIDF.1760 |
RPL10.Conn IDF Huts - (GSMDF to GSIDF) NS3 N31 WBS Summary | GSIDFN31 | Not Started | 04/13/26 | 05/19/26 | 33.8 | 33.8 |
|
312.5 |
RPL10.WP2.GSIDF.1780 |
RPL10.Conn GSIDFN31 Set Infrastructure (Racks, Waterfalls etc.) | Infrastructure | Not Started | 04/13/26 | 04/17/26 | 6.2 | 6.2 |
|
213.8 |
RPL10.WP2.GSIDF.2000 |
RPL10.Conn Ext IDF Huts - Install GS Cabling Pull/Term/Test (13x GS.IDF) ~5060 LF - WBS Summary | Exterior | Not Started | 04/13/26 | 08/17/26 | 111.2 | 111.2 |
|
410.0 |
RPL10.WP2.GSIDF.2800 |
RPL10.Conn IDF Huts - (GSMDF to GSIDF) mCup NX11 WBS Summary | GSIDFNX11 | Not Started | 04/13/26 | 05/13/26 | 28.8 | 28.8 |
|
492.5 |
RPL10.WP2.GSIDF.2820 |
RPL10.Conn GSIDFNX11 Set Infrastructure (Racks, Waterfalls etc.) | Infrastructure | Not Started | 04/13/26 | 04/17/26 | 6.2 | 6.2 |
|
28.8 |
RPL10.WP2.GSIDF.2880 |
RPL10.Conn IDF Huts - (GSMDF to GSIDF) mCup NX12 WBS Summary | GSIDFNX12 | Not Started | 04/13/26 | 05/22/26 | 37.5 | 37.5 |
|
483.8 |
RPL10.WP2.GSIDF.2900 |
RPL10.Conn GSIDFNX12 Set Infrastructure (Racks, Waterfalls etc.) | Infrastructure | Not Started | 04/13/26 | 04/17/26 | 6.2 | 6.2 |
|
28.8 |
RPL10.WP2.GSIDF.2960 |
RPL10.Conn GSIDFNX13 Set Infrastructure (Racks, Waterfalls etc.) | Infrastructure | Not Started | 04/13/26 | 04/17/26 | 6.2 | 6.2 |
|
40.0 |
RPL10.WP2.MDF1.1000 |
RPL10.Conn GSMDF1 Set Infrastructure (Wall mounting enclosures, Tier1 Basket Tray, Waterfalls etc.) | Infrastructure | Not Started | 04/13/26 | 04/15/26 | 3.8 | 3.8 |
|
45.0 |
RPL10.WP2.MDF2.1000 |
RPL10.Conn GSMDF2 Set Infrastructure (Wall mounting enclosures, Tier1 Basket Tray, Waterfalls etc.) | Infrastructure | Not Started | 04/13/26 | 04/15/26 | 3.8 | 3.8 |
|
45.0 |
RPL10.CFCI.4830 |
RPL10 - Prep / Submit for Review - Carpet | (CFCI) Div. 09 - Carpet | Not Started | 04/14/26 | 05/11/26 | 25.0 | 25.0 |
|
146.2 |
RPL10.CFCI.4880 |
RPL10 - Submittal Rvw/App'l -Epoxy Flooring (Spec 09 67 23) | (CFCI) Div. 09 - Epoxy Flooring | Not Started | 04/14/26 | 05/11/26 | 25.0 | 25.0 |
|
171.2 |
RPL10.CFCI.5070 |
RPL10 - Submittal Rvw/App'l - Specialities | (CFCI) Div. 10 - Specialities | Not Started | 04/14/26 | 05/11/26 | 25.0 | 25.0 |
|
113.8 |
RPL10.CFCI.5690 |
RPL10 - Fabricate / Deliver - Glass / Frames | Glass & Glazing (Alum. Entrances & Curtainwall) | Not Started | 04/14/26 | 07/22/26 | 87.5 | 87.5 |
|
125.0 |
RPL10.EY.NS4.01140 |
RPL10.EY.NS4 - Install Tent Electrical Panels | Tent and Temp Conditions | Not Started | 04/14/26 | 04/20/26 | 6.2 | 6.2 |
|
116.2 |
RPL10.EY.NS4.01150 |
RPL10.EY.NS4 - Install Tent Heating and Cooling Equipment | Tent and Temp Conditions | Not Started | 04/14/26 | 04/20/26 | 6.2 | 6.2 |
|
115.0 |
RPL10.EY.NS4.01160 |
RPL10.EY.NS4 - Install Tent Overhead Doors | Tent and Temp Conditions | Not Started | 04/14/26 | 04/20/26 | 6.2 | 6.2 |
|
123.8 |
RPL10.EY.NS4.01190 |
RPL10.EY.NS4 - Install Tent Mechanical Tie-ins | Tent and Temp Conditions | Not Started | 04/14/26 | 04/21/26 | 7.5 | 7.5 |
|
115.0 |
RPL10.EY.SSB.01175 |
RPL10.EY.SSB - Install Mechanical Tie-ins | Tie-ins | Not Started | 04/14/26 | 04/27/26 | 12.5 | 12.5 |
|
35.0 |
RPL10.INT.CTRC.01380 |
RPL10.Interior.Center-Corridor - BoW - Install Cable Tray | Balance of Walls & OverHead | Not Started | 04/14/26 | 04/20/26 | 6.2 | 6.2 |
|
72.5 |
RPL10.INT.ENDC.6400 |
RPL10.Interior.End-Corridor - Priority - QC - P7 Wall - Backing/In-Wall | Priority Wall (P7) - Grid Line 10-02 | Not Started | 04/14/26 | 04/15/26 | 2.5 | 2.5 |
|
153.8 |
RPL10.INT.NS1.01203 |
RPL10.Interior.NS1 - MES Skids - CDU Tie-Ins | NS1 - MES Skids | Not Started | 04/14/26 | 05/15/26 | 30.0 | 30.0 |
|
161.2 |
RPL10.INT.NS1.01330 |
RPL10.Interior.NS1 - Control Fault Domain 6 SQ1.1 - Install LV Side Aisle Cable Tray | LV Side Tie-ins | Not Started | 04/14/26 | 04/20/26 | 6.2 | 6.2 |
|
51.2 |
RPL10.INT.NS1.01470 |
RPL10.Interior.NS1 - Control Fault Domain 5 SQ2.1 - Install LV Side Aisle Cable Tray | LV Side Tie-ins | Not Started | 04/14/26 | 04/17/26 | 5.0 | 5.0 |
|
66.2 |
RPL10.INT.NS2.01230 |
RPL10.Interior.NS2 - OFE - Control Fault Domain 5 SQ2.2 (LV Side Aisle, HAC, Mech Side Aisle) - WBS Summary | OFE NS2 Control Fault Domain 5 | Not Started | 04/14/26 | 06/10/26 | 51.2 | 51.2 |
|
-17.5 |
RPL10.INT.NS2.02505 |
RPL10.Interior.NS2 - OFE - Control Fault Domain 5 SQ2.2 (LV Side Aisle) Upto Row 9 | OFE NS2 Control Fault Domain 5 | Not Started | 04/14/26 | 04/17/26 | 5.0 | 5.0 |
|
-27.5 |
RPL10.MCUP.LP2.1480 |
RPL10.MCUP.Loop 2 - Set Electrical Skids #6 | OFE | Not Started | 04/14/26 | 04/15/26 | 2.5 | 2.5 |
|
138.8 |
RPL10.MCUP.LP2.1500 |
RPL10.MCUP.Loop 2 - Set Electrical Skids #8 | OFE | Not Started | 04/14/26 | 04/15/26 | 2.5 | 2.5 |
|
138.8 |
RPL10.MCUP.LP2.1800 |
RPL10.MCUP.Loop 2 - Tie-in Mechanical #4 WBS Summary | Tie-in Mechanical #4 | Not Started | 04/14/26 | 04/24/26 | 11.2 | 11.2 |
|
143.8 |
RPL10.MCUP.LP2.2640 |
RPL10.MCUP.Loop 2 - Facility Water Tie-in Mechanical #4 | Tie-in Mechanical #4 | Not Started | 04/14/26 | 04/16/26 | 3.8 | 3.8 |
|
143.8 |
RPL.10.D.X3760.XG |
RMUs/MV Skids Set - mCUP South | Give Milestones (XREFs) | Not Started | 04/15/26 | 04/15/26 | 0.0 | 0.0 |
|
1987.5 |
RPL10.EY.EF1.01150 |
RPL10.EY.EF1 - Install RPL-2 FSP Columns F/R/P | Fiber Support Platform - RPL-2 | Not Started | 04/15/26 | 04/21/26 | 6.2 | 6.2 |
|
217.5 |
RPL10.INT.NS1.01600 |
RPL10.Interior.NS1 - Control Fault Domain 4 SQ3.1 - Install LV Side Aisle HAC Busway | LV Side Tie-ins | Not Started | 04/15/26 | 04/20/26 | 5.0 | 5.0 |
|
101.2 |