Schedule Viewer

Last schedule upload: D3-R25005-00-RPL06 — 6139 activities — 04/16/2026 08:19 AM CT
RPL10 - GC LIVE SCHEDULE - Data Date 20260412.xer · Uploaded Apr 16, 2026 12:51 PM · 8408 activities
Experimental Auto-populate checklist dates from schedule:
Clear
100
Activities Shown
0
Completed
0
In Progress
1
Critical
Activity ID Activity Name WBS Status Start Finish Dur (d) Rem (d) % Comp Float (d)
RPL10.WP4.NS4.01300 RPL10.Conn NS4.CFD2 Infrastructure - WBS Summary Infrastructure Not Started 10/16/26 10/29/26 12.5 12.5
0%
57.5
RPL10.WP4.NS4.01320 RPL10.Conn NS4.CFD2 Infrastructure Infrastructure Not Started 10/16/26 10/29/26 12.5 12.5
0%
57.5
GCD.RPL10.3905 L3/L4 Finish - NS1 Rows 9-16 NS Not Started 10/19/26 10/19/26 0.0 0.0
0%
52.5
GCD.RPL10.4845 L3/L4 Finish - NS2 Rows 9-16 NS Not Started 10/19/26 10/19/26 0.0 0.0
0%
63.8
RPL10.CX.NS3.01060 RPL10.CX.NS3 - L3/L4 - House Power (for mechainical) NS3 HOUSE POWER Not Started 10/19/26 10/30/26 12.5 12.5
0%
61.2
RPL10.INT.NS3.01380 RPL10.Interior.NS3 - Control Fault Domain 2 SQ8.2 - Install copper from GS.IDF to BMS and EPMS panels Remaining Tie-ins post Mech Side Aisle install Not Started 10/19/26 11/16/26 25.0 25.0
0%
45.0
RPL10.INT.NS3.01450 RPL10.Interior.NS3 - Control Fault Domain 3 SQ9.2 - Pull BMS from panel to devices Remaining Tie-ins post Mech Side Aisle install Not Started 10/19/26 11/16/26 25.0 25.0
0%
60.0
RPL10.INT.NS3.01460 RPL10.Interior.NS3 - Control Fault Domain 3 SQ9.2 - Pull EPMS from panel to devices Remaining Tie-ins post Mech Side Aisle install Not Started 10/19/26 11/16/26 25.0 25.0
0%
60.0
RPL10.INT.NS3.01470 RPL10.Interior.NS3 - Control Fault Domain 3 SQ9.2 - Set UPS and Panel (2) and GS.IDF N32 Remaining Tie-ins post Mech Side Aisle install Not Started 10/19/26 11/16/26 25.0 25.0
0%
47.5
RPL10.W3B.FE.011336 RPL10.Conn EF2B<>NS2.CFD1 (P1-4) Pull Fiber Trunk (384F) [EF<>SSW] EF2B<>NS2.6 (P1-4) [EF<>SSW] Not Started 10/19/26 10/20/26 2.5 2.5
0%
41.2
RPL10.WP3A.EF2B.1115 RPL10.Conn EF2B(OPE)<>EF1F(MBOX) Pull/Install/Test OSP Cabling (for RPL09) - P4 EF2B<>EF2F Not Started 10/19/26 10/26/26 7.5 7.5
0%
148.8
RPL10.WP3B.FE.09200 RPL10.Conn NS2.CFD1 (FE) ISP Cabling - WBS Summary FENW (Front End Network) Not Started 10/19/26 12/10/26 45.0 45.0
0%
11.2
RPL10.WP3B.FE.09340 RPL10.Conn EF2B<>NS2.CFD1 (P1-4) Pull/Install/Test - WBS Summary EF2B<>NS2.6 (P1-4) [EF<>SSW] Not Started 10/19/26 12/02/26 37.5 37.5
0%
11.2
RPL10.WP4.018540 RPL10.Conn NS2.CFD4.23 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] Install (A-End/Passive) Duplex Jumper [MA<>JXSW] Not Started 10/19/26 10/20/26 2.5 2.5
0%
76.2
RPL10.WP4.018700 RPL10.Conn NS2.CFD4.48<>31-35 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] Install (A-End/Passive) Duplex Jumper [RSW<>FSW] Not Started 10/19/26 10/20/26 2.5 2.5
0%
71.2
RPL10.WP4.030100 RPL10.Conn NS4.CFD3.48<>21-25 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] Prefab Not Started 10/19/26 10/22/26 5.0 5.0
0%
133.8
RPL10.WP4.032540 RPL10.Conn NS1.CFD2.35 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] Install Duplex Jumper [MA<>JXSW] Not Started 10/19/26 10/20/26 2.5 2.5
0%
55.0
RPL10.WP4.032860 RPL10.Conn NS2.CFD4.19 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] Install Duplex Jumper [MA<>JXSW] Not Started 10/19/26 10/20/26 2.5 2.5
0%
66.2
RPL10.WP4.04680 RPL10.Conn NS2.CFD1.48<>41-44 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 10/19/26 10/20/26 2.5 2.5
0%
73.8
RPL10.WP4.05140 RPL10.Conn NS3.CFD2.48<>16-20 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 10/19/26 10/23/26 6.2 6.2
0%
172.5
RPL10.WP4.05160 RPL10.Conn NS3.CFD2.48<>21-25 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 10/19/26 10/23/26 6.2 6.2
0%
175.0
RPL10.WP4.06980 RPL10.Conn NS4.CFD2.48<>16-20 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 10/19/26 10/23/26 6.2 6.2
0%
160.0
RPL10.WP4.07000 RPL10.Conn NS4.CFD2.48<>21-25 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 10/19/26 10/23/26 6.2 6.2
0%
162.5
RPL10.WP4.NS1.01680 RPL10.Conn NS1.CFD2 Network Suite [JXSW<>MA] Fanouts Post ORv3 Rack Not Started 10/19/26 10/28/26 10.0 10.0
0%
30.0
RPL10.INT.NS2.01970 RPL10.Interior.NS2 - Final Punch Walk Tie-Ins Not Started 10/20/26 10/21/26 2.5 2.5
0%
83.8
RPL10.W3B.FE.011816 RPL10.Conn EF1B<>NS1.CFD2 (P2-3) Install Fiber Trunk (288F) [EF<>JXSW] EF1B<>NS1.5 (P2-3) [EF<>JXSW] Not Started 10/20/26 10/22/26 3.8 3.8
0%
18.8
RPL10.W3B.FE.012231 RPL10.Conn EF1F<>NS2.CFD3 (P2-3) Install Fiber Trunk (288F) [EF<>JXSW] EF1F<>NS2.4 (P2-3) [EF<>JXSW] Not Started 10/20/26 10/22/26 3.8 3.8
0%
11.2
RPL10.W3B.FE.012571 RPL10.Conn EF2F<>NS4.CFD1 (P1-4) Install Fiber Trunk (384F) [EF<>SSW] EF2F<>NS4.1 (P1-4) [EF<>SSW] Not Started 10/20/26 10/21/26 2.5 2.5
0%
37.5
RPL10.W3B.FE.012806 RPL10.Conn EF1B<>NS2.CFD3 (P2-3) Test Fiber Trunk (384F) [EF<>SSW] EF1B<>NS2.4 (P2-3) [EF<>SSW] Not Started 10/20/26 10/21/26 2.5 2.5
0%
17.5
RPL10.W3B.FE.012971 RPL10.Conn EF2B<>NS4.CFD1 (P1-4) Test Fiber Trunk (384F) [EF<>SSW] EF2B<>NS4.1 (P1-4) [EF<>SSW] Not Started 10/20/26 10/21/26 2.5 2.5
0%
57.5
RPL10.W3B.FE.013301 RPL10.Conn EF2F<>NS1.CFD2 (P1-4) Test Fiber Trunk (384F) [EF<>SSW] EF2F<>NS1.5 (P1-4) [EF<>SSW] Not Started 10/20/26 10/21/26 2.5 2.5
0%
21.2
RPL10.WP4.017000 RPL10.Conn NS1.CFD3.29 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] Install (A-End/Passive) Duplex Jumper [MA<>JXSW] Not Started 10/20/26 10/21/26 2.5 2.5
0%
58.8
RPL10.WP4.017160 RPL10.Conn NS1.CFD3.48<>21-25 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] Install (A-End/Passive) Duplex Jumper [RSW<>FSW] Not Started 10/20/26 10/21/26 2.5 2.5
0%
53.8
RPL10.WP4.032780 RPL10.Conn NS2.CFD5.15 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] Install Duplex Jumper [MA<>JXSW] Not Started 10/20/26 10/21/26 2.5 2.5
0%
75.0
RPL10.WP4.04700 RPL10.Conn NS2.CFD1.48<>46-49 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 10/20/26 10/20/26 1.2 1.2
0%
76.2
RPL10.WP4.05180 RPL10.Conn NS3.CFD2.48<>26-30 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 10/20/26 10/23/26 5.0 5.0
0%
177.5
RPL10.WP4.05200 RPL10.Conn NS3.CFD2.48<>31-35 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 10/20/26 10/23/26 5.0 5.0
0%
180.0
RPL10.WP4.07020 RPL10.Conn NS4.CFD2.48<>26-30 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 10/20/26 10/23/26 5.0 5.0
0%
165.0
RPL10.WP4.07040 RPL10.Conn NS4.CFD2.48<>31-35 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 10/20/26 10/23/26 5.0 5.0
0%
167.5
RPL10.WP4.08680 RPL10.Conn NS1.CFD6 Pull/Install Ext. Trunk (24F) [DR<>BB] [DR<>BB] Not Started 10/20/26 10/21/26 2.5 2.5
0%
52.5
RPL10.WP4.NS1.04200 RPL10.Conn NS1.CFD3 GSMDF <> Network Suites Management Trunks Post ORv3 Rack Not Started 10/20/26 10/29/26 10.0 10.0
0%
23.8
RPL.10.D.X1430.XR Ready for Fiber Support Platform Construction - AI 5 (TCCO est Release 21-Oct-26) Connectivity (XREFs) Not Started 10/21/26 10/21/26 0.0 0.0
0%
78.8
RPL.GF.D.N4090.XG DAS/PS System pathways complete SSB, SSBC, NS1, NS2, CNTC, EF1, EF2 RPL10 Give Milestones (XREFs) Not Started 10/21/26 10/21/26 0.0 0.0
0%
1822.5
RPL10.CBL.NIDF.03030 RPL10.Conn NS4.CFD2 (FE) ISP Cabling - WBS Summary FENW (Front End Network) Not Started 10/21/26 12/01/26 33.8 33.8
0%
52.5
RPL10.CX.NS3.01080 RPL10.CX.NS3 - L3/L4 - WBS Summary (Mechanical) NS3 MECHANICAL Not Started 10/21/26 04/01/27 136.2 136.2
0%
41.2
RPL10.CX.NS3.01260 RPL10.CX.NS3 - L3/L4 - Control Fault Domain 1 - FW Flush and Fill NS3 Control Fault Domain 1 Not Started 10/21/26 10/29/26 8.8 8.8
0%
61.2
RPL10.EY.EF2.01200 RPL10.EY.EF2 - Install RPL-5 FSP Columns F/R/P Fiber Support Platform - RPL-5 Not Started 10/21/26 10/27/26 6.2 6.2
0%
78.8
RPL10.INT.NS3.01260 RPL10.Interior.NS3 - Control Fault Domain 1 SQ7.2 - L2 Checklist Completion Remaining Tie-ins post Mech Side Aisle install Not Started 10/21/26 11/18/26 25.0 25.0
0%
38.8
RPL10.INT.NS3.02700 RPL10.Interior.NS3 - OFE - Control Fault Domain 4 SQ10.2 (HAC) OFE NS3 Control Fault Domain 4 Not Started 10/21/26 11/03/26 12.5 12.5
0%
60.0
RPL10.INT.NS4.01540 RPL10.Interior.NS4 - Control Fault Domain 3 SQ9.1 - L2 Checklist Completion Remaining Tie-ins post Mech Side Aisle install Not Started 10/21/26 11/18/26 25.0 25.0
0%
51.2
RPL10.SSBC.BB.3120 RPL10.Ext.Build Back.SSB-Corr - LO #2 - Install Frame, Doors, Hardware Build Back Exterior Leave Out Wall #2 (Tent Area) Not Started 10/21/26 10/22/26 2.5 2.5
0%
20.0
RPL10.W3B.FE.011061 RPL10.Conn EF1B<>NS4.CFD2 (P2-3) Pull Fiber Trunk (288F) [EF<>JXSW] EF1B<>NS4.2 (P2-3) [EF<>JXSW] Not Started 10/21/26 10/22/26 2.5 2.5
0%
53.8
RPL10.W3B.FE.011141 RPL10.Conn EF2B<>NS4.CFD2 (P1-4) Pull Fiber Trunk (288F) [EF<>JXSW] EF2B<>NS4.2 (P1-4) [EF<>JXSW] Not Started 10/21/26 10/23/26 3.8 3.8
0%
40.0
RPL10.W3B.FE.011436 RPL10.Conn EF1F<>NS2.CFD2 (P2-3) Pull Fiber Trunk (288F) [EF<>JXSW] EF1F<>NS2.5 (P2-3) [EF<>JXSW] Not Started 10/21/26 10/27/26 6.2 6.2
0%
28.8
RPL10.W3B.FE.011736 RPL10.Conn EF2F<>NS2.CFD1 (P1-4) Pull Fiber Trunk (384F) [EF<>SSW] EF2F<>NS2.6 (P1-4) [EF<>SSW] Not Started 10/21/26 10/22/26 2.5 2.5
0%
41.2
RPL10.WP3B.FE.02360 RPL10.Conn EF2B<>NS4.CFD2 (P1-4) Pull/Install/Test - WBS Summary* EF2B<>NS4.2 (P1-4) [EF<>JXSW] Not Started 10/21/26 11/03/26 12.5 12.5
0%
56.2
RPL10.WP3B.FE.02440 RPL10.Conn EF1B<>NS4.CFD2 (P2-3) Pull/Install/Test - WBS Summary EF1B<>NS4.2 (P2-3) [EF<>JXSW] Not Started 10/21/26 11/18/26 25.0 25.0
0%
53.8
RPL10.WP3B.FE.09060 RPL10.Conn EF1F<>NS2.CFD2 (P2-3) Pull/Install/Test - WBS Summary EF1F<>NS2.5 (P2-3) [EF<>JXSW] Not Started 10/21/26 11/24/26 30.0 30.0
0%
11.2
RPL10.WP3B.FE.09300 RPL10.Conn EF2F<>NS2.CFD1 (P1-4) Pull/Install/Test - WBS Summary EF2F<>NS2.6 (P1-4) [EF<>SSW] Not Started 10/21/26 12/04/26 37.5 37.5
0%
11.2
RPL10.WP4.011880 RPL10.Conn NS1.CFD2 Pull/Install/Test Multidrop Cable (288F) [EF<>JXSW] Pull/Install Trunk & Multidrop Cable Not Started 10/21/26 10/28/26 7.5 7.5
0%
46.2
RPL10.WP4.018560 RPL10.Conn NS2.CFD4.24 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] Install (A-End/Passive) Duplex Jumper [MA<>JXSW] Not Started 10/21/26 10/22/26 2.5 2.5
0%
76.2
RPL10.WP4.018720 RPL10.Conn NS2.CFD4.48<>36-40 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] Install (A-End/Passive) Duplex Jumper [RSW<>FSW] Not Started 10/21/26 10/22/26 2.5 2.5
0%
71.2
RPL10.WP4.030300 RPL10.Conn NS4.CFD4.48<>21-25 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] Prefab Not Started 10/21/26 10/26/26 5.0 5.0
0%
131.2
RPL10.WP4.032560 RPL10.Conn NS1.CFD2.36 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] Install Duplex Jumper [MA<>JXSW] Not Started 10/21/26 10/22/26 2.5 2.5
0%
55.0
RPL10.WP4.032880 RPL10.Conn NS2.CFD4.20 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] Install Duplex Jumper [MA<>JXSW] Not Started 10/21/26 10/22/26 2.5 2.5
0%
66.2
RPL10.WP4.05220 RPL10.Conn NS3.CFD2.48<>36-40 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 10/21/26 10/23/26 3.8 3.8
0%
182.5
RPL10.WP4.06780 RPL10.Conn NS4.CFD2.10 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] Pull Duplex Jumper [MA<>JXSW] Not Started 10/21/26 10/23/26 3.8 3.8
0%
147.5
RPL10.WP4.07060 RPL10.Conn NS4.CFD2.48<>36-40 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 10/21/26 10/23/26 3.8 3.8
0%
170.0
RPL10.WP4.09200 RPL10.Conn NS2.CFD5 Pull/Install/Test Trunk (192F) [MA<>JXSW] Pull/Install Trunk & Multidrop Cable Not Started 10/21/26 11/03/26 12.5 12.5
0%
66.2
RPL10.WP4.09720 RPL10.Conn NS1.CFD6.46<>04 Pull/Install Trunk (384F) [MA<>EB] [MA<>EB] Not Started 10/21/26 10/26/26 5.0 5.0
0%
23.8
GCD.RPL10.5285 L3/L4 Finish EY - NS3 EY Not Started 10/22/26 10/22/26 0.0 0.0
0%
175.0
RPL10.CX.NS2.01180 RPL10.CX.NS2 - L3/L4 - Elec. Domain 02/01 NS2 ELECTRICAL Not Started 10/22/26 10/27/26 5.0 5.0
0%
-27.5
RPL10.CX.SSBC.01020 RPL10.CX.SSB COR - L3/L4 Remaining Electrical Equipment SSB Corridor Not Started 10/22/26 10/28/26 6.2 6.2
0%
53.8
RPL10.CX.SSBC.01040 RPL10.CX.SSB COR - L3/L4 Remaining Mechanical Equipment SSB Corridor Not Started 10/22/26 10/28/26 6.2 6.2
0%
53.8
RPL10.EY.NS2.01430 RPL10.EY.NS2 - Install Irrigation Hardscape and Landscape Not Started 10/22/26 11/04/26 12.5 12.5
0%
327.5
RPL10.EY.NS2.01440 RPL10.EY.NS2 - Install Exterior Signage Hardscape and Landscape Not Started 10/22/26 11/04/26 12.5 12.5
0%
81.2
RPL10.EY.NS2.01450 RPL10.EY.NS2 - Install Remaining Electrical Tie-ins Build Back Exterior Leave Out Wall #2 (Tent Area) Not Started 10/22/26 11/02/26 10.0 10.0
0%
18.8
RPL10.W3B.FE.012051 RPL10.Conn EF1B<>NS4.CFD1 (P2-3) Install Fiber Trunk (384F) [EF<>SSW] EF1B<>NS4.1 (P2-3) [EF<>SSW] Not Started 10/22/26 10/23/26 2.5 2.5
0%
37.5
RPL10.W3B.FE.013371 RPL10.Conn EF2F<>NS4.CFD1 (P1-4) Test Fiber Trunk (384F) [EF<>SSW] EF2F<>NS4.1 (P1-4) [EF<>SSW] Not Started 10/22/26 10/23/26 2.5 2.5
0%
57.5
RPL10.WP2.02020 RPL10.Conn GSMDF1<>NS1.CFD6 MSA Pull, Install, & Patch PON Trunks GSMDF1 <> NS1 - MES side Not Started 10/22/26 10/23/26 2.5 2.5
0%
32.5
RPL10.WP2.02140 RPL10.Conn GSMDF2<>NS1.CFD6 LVA Pull, Install, & Patch PON Trunks GSMDF2 <> NS1 - LV side Not Started 10/22/26 10/23/26 2.5 2.5
0%
32.5
RPL10.WP2.02260 RPL10.Conn GSMDF1<>NS2.CFD6 LVA Pull, Install, & Patch PON Trunks GSMDF1 <> NS2 - LV side Not Started 10/22/26 10/23/26 2.5 2.5
0%
46.2
RPL10.WP2.02380 RPL10.Conn GSMDF2<>NS2.CFD6 MSA Pull, Install, & Patch PON Trunks GSMDF2 <> NS2 - MES side Not Started 10/22/26 10/23/26 2.5 2.5
0%
46.2
RPL10.WP2.02500 RPL10.Conn GSMDF1<>NS4.CFD1 MSA Pull, Install, & Patch PON Trunks GSMDF1 <> NS4 - MES side Not Started 10/22/26 10/23/26 2.5 2.5
0%
146.2
RPL10.WP2.02620 RPL10.Conn GSMDF2<>NS4.CFD1 LVA Pull, Install, & Patch PON Trunks GSMDF2 <> NS4 - LV side Not Started 10/22/26 10/23/26 2.5 2.5
0%
146.2
RPL10.WP2.OP.1000 RPL10.Conn NS1.CFD6 > GSMDF1 (Optical Backbone) - (Pull, Splice & terminate) Optical Backbone Not Started 10/22/26 10/28/26 6.2 6.2
0%
60.0
RPL10.WP2.OP.1020 RPL10.Conn NS1.CFD1 > GSMDF1 (Optical Backbone) - (Pull, Splice & terminate) Optical Backbone Not Started 10/22/26 10/28/26 6.2 6.2
0%
60.0
RPL10.WP2.OP.1040 RPL10.Conn NS1.CFD6 > GSMDF2 (Optical Backbone) - (Pull, Splice & terminate) Optical Backbone Not Started 10/22/26 10/28/26 6.2 6.2
0%
60.0
RPL10.WP2.OP.1060 RPL10.Conn NS1.CFD1 > GSMDF2 (Optical Backbone) - (Pull, Splice & terminate) Optical Backbone Not Started 10/22/26 10/28/26 6.2 6.2
0%
60.0
RPL10.WP2.OP.1080 RPL10.Conn NS2.CFD6 > GSMDF2 (Optical Backbone) - (Pull, Splice & terminate) Optical Backbone Not Started 10/22/26 10/28/26 6.2 6.2
0%
71.2
RPL10.WP2.OP.1100 RPL10.Conn NS2.CFD1 > GSMDF2 (Optical Backbone) - (Pull, Splice & terminate) Optical Backbone Not Started 10/22/26 10/28/26 6.2 6.2
0%
52.5
RPL10.WP2.OP.1120 RPL10.Conn NS2.CFD6 > GSMDF1 (Optical Backbone) - (Pull, Splice & terminate) Optical Backbone Not Started 10/22/26 10/28/26 6.2 6.2
0%
71.2
RPL10.WP2.OP.1140 RPL10.Conn NS2.CFD1 > GSMDF1 (Optical Backbone) - (Pull, Splice & terminate) Optical Backbone Not Started 10/22/26 10/28/26 6.2 6.2
0%
52.5
RPL10.WP4.01000 RPL10.Conn NS1.CFD6 Pull Duplex Jumper (LC<>LC) [DR<>BB] [DR<>BB] Not Started 10/22/26 10/22/26 1.2 1.2
0%
52.5
RPL10.WP4.011920 RPL10.Conn NS2.CFD4 Pull/Install/Test Multidrop Cable (288F) [EF<>JXSW] Pull/Install Trunk & Multidrop Cable Not Started 10/22/26 10/29/26 7.5 7.5
0%
57.5
RPL10.WP4.017020 RPL10.Conn NS1.CFD3.30 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] Install (A-End/Passive) Duplex Jumper [MA<>JXSW] Not Started 10/22/26 10/23/26 2.5 2.5
0%
58.8
RPL10.WP4.017180 RPL10.Conn NS1.CFD3.48<>26-30 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] Install (A-End/Passive) Duplex Jumper [RSW<>FSW] Not Started 10/22/26 10/23/26 2.5 2.5
0%
53.8
RPL10.WP4.030940 RPL10.Conn NS3.CFD1.48<>31-35 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] Prefab Not Started 10/22/26 10/26/26 3.8 3.8
0%
152.5
RPL10.WP4.032800 RPL10.Conn NS2.CFD5.16 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] Install Duplex Jumper [MA<>JXSW] Not Started 10/22/26 10/23/26 2.5 2.5
0%
75.0
RPL10.WP4.05240 RPL10.Conn NS3.CFD2.48<>41-44 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 10/22/26 10/23/26 2.5 2.5
0%
185.0