Schedule Viewer
Last schedule upload: D3-R25005-00-RPL06 — 6139 activities — 04/16/2026 08:19 AM CT
RPL10 - GC LIVE SCHEDULE - Data Date 20260412.xer
· Uploaded Apr 16, 2026 12:51 PM
· 8408 activities
Experimental
Auto-populate checklist dates from schedule:
100
Activities Shown
0
Completed
0
In Progress
3
Critical
| Activity ID | Activity Name | WBS | Status | Start | Finish | Dur (d) | Rem (d) | % Comp | Float (d) |
|---|---|---|---|---|---|---|---|---|---|
RPL10.WP4.07080 |
RPL10.Conn NS4.CFD2.48<>41-44 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 10/22/26 | 10/23/26 | 2.5 | 2.5 |
|
172.5 |
RPL10.CX.NS2.01170 |
RPL10.CX.NS2 - L3/L4 - Control Fault Domain 2 | NS2 Control Fault Domain 2 | Not Started | 10/23/26 | 11/16/26 | 20.0 | 20.0 |
|
17.5 |
RPL10.Conn.MS.01430 |
Wifi Ready - NS2 | Connectivity Milestones | Not Started | 10/23/26 | 10/23/26 | 0.0 | 0.0 |
|
350.0 |
RPL10.INT.NS4.01680 |
RPL10.Interior.NS4 - Control Fault Domain 4 SQ10.1 - L2 Checklist Completion | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/23/26 | 11/20/26 | 25.0 | 25.0 |
|
72.5 |
RPL10.SSBC.BB.3130 |
RPL10.Ext.Build Back.SSB-Corr - LO #2 - Hang Exterior & GS MDF Mechanical Drywall | Build Back Exterior Leave Out Wall #2 (Tent Area) | Not Started | 10/23/26 | 10/28/26 | 5.0 | 5.0 |
|
20.0 |
RPL10.W3B.FE.011256 |
RPL10.Conn EF1B<>NS4.CFD2 (P2-3) Pull Fiber Trunk (384F) [EF<>SSW] | EF1B<>NS4.2 (P2-3) [EF<>SSW] | Not Started | 10/23/26 | 10/23/26 | 1.2 | 1.2 |
|
56.2 |
RPL10.W3B.FE.011981 |
RPL10.Conn EF1B<>NS1.CFD2 (P2-3) Install Fiber Trunk (384F) [EF<>SSW] | EF1B<>NS1.5 (P2-3) [EF<>SSW] | Not Started | 10/23/26 | 10/26/26 | 2.5 | 2.5 |
|
18.8 |
RPL10.W3B.FE.012406 |
RPL10.Conn EF1F<>NS2.CFD3 (P2-3) Install Fiber Trunk (384F) [EF<>SSW] | EF1F<>NS2.4 (P2-3) [EF<>SSW] | Not Started | 10/23/26 | 10/26/26 | 2.5 | 2.5 |
|
11.2 |
RPL10.W3B.FE.012616 |
RPL10.Conn EF1B<>NS1.CFD2 (P2-3) Test Fiber Trunk (288F) [EF<>JXSW] | EF1B<>NS1.5 (P2-3) [EF<>JXSW] | Not Started | 10/23/26 | 10/26/26 | 2.5 | 2.5 |
|
20.0 |
RPL10.W3B.FE.013031 |
RPL10.Conn EF1F<>NS2.CFD3 (P2-3) Test Fiber Trunk (288F) [EF<>JXSW] | EF1F<>NS2.4 (P2-3) [EF<>JXSW] | Not Started | 10/23/26 | 10/26/26 | 2.5 | 2.5 |
|
16.2 |
RPL10.WP3A.EF2F.1035 |
RPL10.Conn EF2F(OPE)<>EF1F(MBOX) Pull/Install/Test OSP Cabling (for RPL08) - P4 | EF2F<>EF1F | Not Started | 10/23/26 | 11/03/26 | 10.0 | 10.0 |
|
141.2 |
RPL10.WP3B.FE.02480 |
RPL10.Conn EF1B<>NS4.CFD2 (P2-3) Pull/Install/Test - WBS Summary* | EF1B<>NS4.2 (P2-3) [EF<>SSW] | Not Started | 10/23/26 | 11/20/26 | 25.0 | 25.0 |
|
53.8 |
RPL10.WP4.011400 |
RPL10.Conn NS1.CFD6 Pull/Install In-Rack Fanout (LC<>MMC) [DR<>BB] | [DR<>BB] | Not Started | 10/23/26 | 10/26/26 | 2.5 | 2.5 |
|
52.5 |
RPL10.WP4.015980 |
RPL10.Conn NS1.CFD6 Install Duplex Jumper (LC<>LC) [DR<>BB] | [DR<>BB] | Not Started | 10/23/26 | 10/26/26 | 2.5 | 2.5 |
|
62.5 |
RPL10.WP4.018740 |
RPL10.Conn NS2.CFD4.48<>41-44 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 10/23/26 | 10/26/26 | 2.5 | 2.5 |
|
71.2 |
RPL10.WP4.030120 |
RPL10.Conn NS4.CFD3.48<>26-30 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 10/23/26 | 10/28/26 | 5.0 | 5.0 |
|
133.8 |
RPL10.WP4.031280 |
RPL10.Conn NS3.CFD3.48<>16-20 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 10/23/26 | 10/28/26 | 5.0 | 5.0 |
|
136.2 |
RPL10.WP4.032580 |
RPL10.Conn NS1.CFD2.37 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install Duplex Jumper [MA<>JXSW] | Not Started | 10/23/26 | 10/26/26 | 2.5 | 2.5 |
|
55.0 |
RPL10.WP4.032900 |
RPL10.Conn NS2.CFD4.21 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install Duplex Jumper [MA<>JXSW] | Not Started | 10/23/26 | 10/26/26 | 2.5 | 2.5 |
|
66.2 |
RPL10.WP4.034580 |
RPL10.Conn NS1.CFD1 Pull/Install Trunk (384F) [BB<>EB] | [BB<>EB] | Not Started | 10/23/26 | 11/03/26 | 10.0 | 10.0 |
|
0.0 |
RPL10.WP4.034760 |
RPL10.Conn NS1.CFD6 Pull/Install Trunk (384F) [EB<>DR] | [EB<>DR] | Not Started | 10/23/26 | 10/27/26 | 3.8 | 3.8 |
|
61.2 |
RPL10.WP4.05260 |
RPL10.Conn NS3.CFD2.48<>46-49 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 10/23/26 | 10/23/26 | 1.2 | 1.2 |
|
187.5 |
RPL10.WP4.07100 |
RPL10.Conn NS4.CFD2.48<>46-49 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 10/23/26 | 10/23/26 | 1.2 | 1.2 |
|
175.0 |
RPL10.WP4.09840 |
RPL10.Conn NS1.CFD1 Pull/Install Trunk (384F) [RSW<>FSW] | [RSW<>FSW] | Not Started | 10/23/26 | 10/30/26 | 7.5 | 7.5 |
|
57.5 |
RPL10.WP4.NS2.02680 |
RPL10.Conn NS2.CFD4 GSMDF <> Network Suites Management Trunks | Post ORv3 Rack | Not Started | 10/23/26 | 11/03/26 | 10.0 | 10.0 |
|
6.2 |
RPL10.WP4.NS2.03140 |
RPL10.Conn NS2.CFD2 Network Suite [JXSW<>MA] Multi Drop Cable | Pre ORv3 Rack | Not Started | 10/23/26 | 11/03/26 | 10.0 | 10.0 |
|
26.2 |
GCD.RPL10.4985 |
L3/L4 Start - NS4 Rows 1-8 | NS | Not Started | 10/26/26 | 10/26/26 | 0.0 | 0.0 |
|
161.2 |
RPL10.CX.NS4.01040 |
RPL10.CX.NS4 - L3/L4 - Elec. Domain 01/02 | NS4 ELECTRICAL | Not Started | 10/26/26 | 10/29/26 | 5.0 | 5.0 |
|
48.8 |
RPL10.Conn.MS.01330 |
RPL10.Conn NS1.CFD6 FIM | NS1 | Not Started | 10/26/26 | 11/23/26 | 25.0 | 25.0 |
|
45.0 |
RPL10.INT.NS3.01400 |
RPL10.Interior.NS3 - Control Fault Domain 2 SQ8.2 - L2 Checklist Completion | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/26/26 | 11/23/26 | 25.0 | 25.0 |
|
45.0 |
RPL10.INT.NS3.01500 |
RPL10.Interior.NS3 - Control Fault Domain 3 SQ9.2 - Install Mechanical Side Aisle Cable Tray | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/26/26 | 11/23/26 | 25.0 | 25.0 |
|
47.5 |
RPL10.INT.NS3.01520 |
RPL10.Interior.NS3 - Control Fault Domain 3 SQ9.2 - Install copper from GS.IDF to BMS and EPMS panels (UG from Center ID | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/26/26 | 11/23/26 | 25.0 | 25.0 |
|
53.8 |
RPL10.INT.NS3.01560 |
RPL10.Interior.NS3 - Control Fault Domain 4 SQ10.2 - Install Vesda / FA | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/26/26 | 11/23/26 | 25.0 | 25.0 |
|
72.5 |
RPL10.INT.NS3.01570 |
RPL10.Interior.NS3 - Control Fault Domain 4 SQ10.2 - Install FW | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/26/26 | 11/23/26 | 25.0 | 25.0 |
|
60.0 |
RPL10.INT.NS3.02050 |
RPL10.Interior.NS3 - Control Fault Domain 4 SQ10.2 - Install TW | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/26/26 | 11/23/26 | 25.0 | 25.0 |
|
60.0 |
RPL10.INT.NS3.02720 |
RPL10.Interior.NS3 - OFE - Control Fault Domain 4 SQ10.2 (Mech Side Aisle) | OFE NS3 Control Fault Domain 4 | Not Started | 10/26/26 | 11/04/26 | 10.0 | 10.0 |
|
60.0 |
RPL10.INT.NS3.02920 |
RPL10.Interior.NS3 - Control Fault Domain 4 SQ10.2 - Install Duct (MES Side) | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/26/26 | 11/23/26 | 25.0 | 25.0 |
|
60.0 |
RPL10.W3B.FE.011376 |
RPL10.Conn EF2B<>NS4.CFD2 (P1-4) Pull Fiber Trunk (384F) [EF<>SSW] | EF2B<>NS4.2 (P1-4) [EF<>SSW] | Not Started | 10/26/26 | 10/27/26 | 2.5 | 2.5 |
|
40.0 |
RPL10.W3B.FE.011461 |
RPL10.Conn EF1F<>NS4.CFD2 (P2-3) Pull Fiber Trunk (288F) [EF<>JXSW] | EF1F<>NS4.2 (P2-3) [EF<>JXSW] | Not Started | 10/26/26 | 10/27/26 | 2.5 | 2.5 |
|
56.2 |
RPL10.W3B.FE.012451 |
RPL10.Conn EF1F<>NS4.CFD1 (P2-3) Install Fiber Trunk (384F) [EF<>SSW] | EF1F<>NS4.1 (P2-3) [EF<>SSW] | Not Started | 10/26/26 | 10/27/26 | 2.5 | 2.5 |
|
37.5 |
RPL10.W3B.FE.012851 |
RPL10.Conn EF1B<>NS4.CFD1 (P2-3) Test Fiber Trunk (384F) [EF<>SSW] | EF1B<>NS4.1 (P2-3) [EF<>SSW] | Not Started | 10/26/26 | 10/27/26 | 2.5 | 2.5 |
|
57.5 |
RPL10.WP2.02040 |
RPL10.Conn GSMDF1<>NS1.CFD5 MSA Pull, Install, & Patch PON Trunks | GSMDF1 <> NS1 - MES side | Not Started | 10/26/26 | 10/27/26 | 2.5 | 2.5 |
|
32.5 |
RPL10.WP2.02160 |
RPL10.Conn GSMDF2<>NS1.CFD5 LVA Pull, Install, & Patch PON Trunks | GSMDF2 <> NS1 - LV side | Not Started | 10/26/26 | 10/27/26 | 2.5 | 2.5 |
|
32.5 |
RPL10.WP2.02280 |
RPL10.Conn GSMDF1<>NS2.CFD5 LVA Pull, Install, & Patch PON Trunks | GSMDF1 <> NS2 - LV side | Not Started | 10/26/26 | 10/27/26 | 2.5 | 2.5 |
|
46.2 |
RPL10.WP2.02400 |
RPL10.Conn GSMDF2<>NS2.CFD5 MSA Pull, Install, & Patch PON Trunks | GSMDF2 <> NS2 - MES side | Not Started | 10/26/26 | 10/27/26 | 2.5 | 2.5 |
|
46.2 |
RPL10.WP2.02520 |
RPL10.Conn GSMDF1<>NS4.CFD2 MSA Pull, Install, & Patch PON Trunks | GSMDF1 <> NS4 - MES side | Not Started | 10/26/26 | 10/27/26 | 2.5 | 2.5 |
|
146.2 |
RPL10.WP2.02640 |
RPL10.Conn GSMDF2<>NS4.CFD2 LVA Pull, Install, & Patch PON Trunks | GSMDF2 <> NS4 - LV side | Not Started | 10/26/26 | 10/27/26 | 2.5 | 2.5 |
|
146.2 |
RPL10.WP3B.FE.02400 |
RPL10.Conn EF2B<>NS4.CFD2 (P1-4) Pull/Install/Test - WBS Summary | EF2B<>NS4.2 (P1-4) [EF<>SSW] | Not Started | 10/26/26 | 11/05/26 | 11.2 | 11.2 |
|
56.2 |
RPL10.WP3B.FE.02420 |
RPL10.Conn EF1F<>NS4.CFD2 (P2-3) Pull/Install/Test - WBS Summary | EF1F<>NS4.2 (P2-3) [EF<>JXSW] | Not Started | 10/26/26 | 11/25/26 | 27.5 | 27.5 |
|
52.5 |
RPL10.WP4.012140 |
RPL10.Conn NS1.CFD6.01<>01 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 10/26/26 | 10/28/26 | 3.8 | 3.8 |
|
45.0 |
RPL10.WP4.012180 |
RPL10.Conn NS1.CFD6.03<>03 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 10/26/26 | 10/28/26 | 3.8 | 3.8 |
|
45.0 |
RPL10.WP4.013100 |
RPL10.Conn NS2.CFD6.01<>01 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 10/26/26 | 10/27/26 | 2.5 | 2.5 |
|
58.8 |
RPL10.WP4.013140 |
RPL10.Conn NS2.CFD6.03<>03 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 10/26/26 | 10/27/26 | 2.5 | 2.5 |
|
58.8 |
RPL10.WP4.015020 |
RPL10.Conn NS4.CFD1.01<>01 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 10/26/26 | 10/28/26 | 3.8 | 3.8 |
|
157.5 |
RPL10.WP4.015060 |
RPL10.Conn NS4.CFD1.03<>03 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 10/26/26 | 10/28/26 | 3.8 | 3.8 |
|
157.5 |
RPL10.WP4.017040 |
RPL10.Conn NS1.CFD3.31 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install (A-End/Passive) Duplex Jumper [MA<>JXSW] | Not Started | 10/26/26 | 10/27/26 | 2.5 | 2.5 |
|
58.8 |
RPL10.WP4.017200 |
RPL10.Conn NS1.CFD3.48<>31-35 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 10/26/26 | 10/27/26 | 2.5 | 2.5 |
|
53.8 |
RPL10.WP4.06800 |
RPL10.Conn NS4.CFD2.11 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] | Pull Duplex Jumper [MA<>JXSW] | Not Started | 10/26/26 | 10/28/26 | 3.8 | 3.8 |
|
147.5 |
RPL10.WP4.NS2.02520 |
RPL10.Conn NS2.CFD5 Network Suite Management and Console In - Row Cabling - PON | Post ORv3 Rack | Not Started | 10/26/26 | 11/04/26 | 10.0 | 10.0 |
|
0.0 |
RPL10.Conn.MS.01610 |
RPL10.Conn NS2.CFD5 FIM | NS2 | Not Started | 10/27/26 | 11/24/26 | 25.0 | 25.0 |
|
55.0 |
RPL10.EY.NS2.01460 |
RPL10.EY.NS2 - Install Remaining Mechanical Tie-ins | Build Back Exterior Leave Out Wall #2 (Tent Area) | Not Started | 10/27/26 | 11/09/26 | 12.5 | 12.5 |
|
12.5 |
RPL10.INT.NS4.02800 |
RPL10.Interior.NS4 - OFE - Control Fault Domain 6 SQ12.1 (HAC) | OFE NS4 Control Fault Domain 6 | Not Started | 10/27/26 | 11/09/26 | 12.5 | 12.5 |
|
82.5 |
RPL10.W3B.FE.011916 |
RPL10.Conn EF2B<>NS2.CFD2 (P1-4) Install Fiber Trunk (288F) [EF<>JXSW] | EF2B<>NS2.5 (P1-4) [EF<>JXSW] | Not Started | 10/27/26 | 10/29/26 | 3.8 | 3.8 |
|
11.2 |
RPL10.W3B.FE.012216 |
RPL10.Conn EF1F<>NS1.CFD2 (P2-3) Install Fiber Trunk (288F) [EF<>JXSW] | EF1F<>NS1.5 (P2-3) [EF<>JXSW] | Not Started | 10/27/26 | 10/29/26 | 3.8 | 3.8 |
|
18.8 |
RPL10.W3B.FE.012781 |
RPL10.Conn EF1B<>NS1.CFD2 (P2-3) Test Fiber Trunk (384F) [EF<>SSW] | EF1B<>NS1.5 (P2-3) [EF<>SSW] | Not Started | 10/27/26 | 10/28/26 | 2.5 | 2.5 |
|
20.0 |
RPL10.W3B.FE.013206 |
RPL10.Conn EF1F<>NS2.CFD3 (P2-3) Test Fiber Trunk (384F) [EF<>SSW] | EF1F<>NS2.4 (P2-3) [EF<>SSW] | Not Started | 10/27/26 | 10/28/26 | 2.5 | 2.5 |
|
16.2 |
RPL10.WP3A.EF2B.1070 |
RPL10.Conn EF2B(OPE)<>EF1B(MBOX) Pull/Install/Test OSP Cabling (for RPL09) - P3 | EF2B<>EF1B | Not Started | 10/27/26 | 11/05/26 | 10.0 | 10.0 |
|
128.8 |
RPL10.WP4.018760 |
RPL10.Conn NS2.CFD4.48<>46-49 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 10/27/26 | 10/28/26 | 2.5 | 2.5 |
|
71.2 |
RPL10.WP4.030320 |
RPL10.Conn NS4.CFD4.48<>26-30 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 10/27/26 | 10/30/26 | 5.0 | 5.0 |
|
131.2 |
RPL10.WP4.030420 |
RPL10.Conn NS4.CFD5.48<>03-05 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 10/27/26 | 10/28/26 | 2.5 | 2.5 |
|
108.8 |
RPL10.WP4.030620 |
RPL10.Conn NS4.CFD6.48<>03-05 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 10/27/26 | 10/28/26 | 2.5 | 2.5 |
|
108.8 |
RPL10.WP4.030960 |
RPL10.Conn NS3.CFD1.48<>36-40 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 10/27/26 | 10/29/26 | 3.8 | 3.8 |
|
152.5 |
RPL10.WP4.032600 |
RPL10.Conn NS1.CFD2.38 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install Duplex Jumper [MA<>JXSW] | Not Started | 10/27/26 | 10/28/26 | 2.5 | 2.5 |
|
55.0 |
RPL10.WP4.032920 |
RPL10.Conn NS2.CFD4.22 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install Duplex Jumper [MA<>JXSW] | Not Started | 10/27/26 | 10/28/26 | 2.5 | 2.5 |
|
66.2 |
RPL10.WP4.08920 |
RPL10.Conn NS2.CFD6 Pull/Install Ext. Trunk (96F) [MA<>EB] | [MA<>EB] | Not Started | 10/27/26 | 11/02/26 | 6.2 | 6.2 |
|
23.8 |
RPL10.WP4.08960 |
RPL10.Conn NS1.CFD6 Pull/Install Trunk (192F) [FSW<>SSW] | [FSW<>SSW] | Not Started | 10/27/26 | 11/05/26 | 10.0 | 10.0 |
|
52.5 |
RPL10.WP4.NS4.03140 |
RPL10.Conn NS4.CFD5 Network - WBS Summary | Network | Not Started | 10/27/26 | 03/30/27 | 128.8 | 128.8 |
|
47.5 |
RPL10.WP4.NS4.03620 |
RPL10.Conn NS4.CFD6 Network - WBS Summary | Network | Not Started | 10/27/26 | 04/09/27 | 138.8 | 138.8 |
|
37.5 |
RPL10.CX.NS2.01460 |
RPL10.CX.NS2 - L3/L4 - Control Fault Domain 1 - TW Flush and Fill | NS2 Control Fault Domain 1 | Not Started | 10/28/26 | 11/06/26 | 10.0 | 10.0 |
|
-27.5 |
RPL10.CX.NS4.01060 |
RPL10.CX.NS4 - L3/L4 - UPS Start-up | NS4 ELECTRICAL | Not Started | 10/28/26 | 11/10/26 | 12.5 | 12.5 |
|
87.5 |
RPL10.CX.NS4.01380 |
RPL10.CX.NS4 - L3/L4 - Control Fault Domain 3 - FW Flush and Fill | NS4 Control Fault Domain 3 | Not Started | 10/28/26 | 11/05/26 | 8.8 | 8.8 |
|
67.5 |
RPL10.Conn.MS.01550 |
RPL10.Conn NS1.CFD5 FIM | NS1 | Not Started | 10/28/26 | 11/25/26 | 25.0 | 25.0 |
|
42.5 |
RPL10.EY.EF2.01240 |
RPL10.EY.EF2 - Install RPL-5 FSP Grounding Wire | Fiber Support Platform - RPL-5 | Not Started | 10/28/26 | 10/29/26 | 2.5 | 2.5 |
|
145.0 |
RPL10.EY.EF2.01830 |
RPL10.EY.EF2 - Install RPL-5 FSP Columns Cap Erect Shoring & Decking & F/R/P | Fiber Support Platform - RPL-5 | Not Started | 10/28/26 | 11/03/26 | 6.2 | 6.2 |
|
78.8 |
RPL10.INT.NS4.01700 |
RPL10.Interior.NS4 - Control Fault Domain 5 SQ11.1 - Install Vesda / FA | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/28/26 | 11/25/26 | 25.0 | 25.0 |
|
72.5 |
RPL10.INT.NS4.01710 |
RPL10.Interior.NS4 - Control Fault Domain 5 SQ11.1 - Install FW | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/28/26 | 11/25/26 | 25.0 | 25.0 |
|
60.0 |
RPL10.INT.NS4.01840 |
RPL10.Interior.NS4 - Control Fault Domain 6 SQ12.1 - Install Vesda / FA | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/28/26 | 11/25/26 | 25.0 | 25.0 |
|
88.8 |
RPL10.INT.NS4.01850 |
RPL10.Interior.NS4 - Control Fault Domain 6 SQ12.1 - Install FW | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/28/26 | 11/25/26 | 25.0 | 25.0 |
|
82.5 |
RPL10.INT.NS4.02070 |
RPL10.Interior.NS4 - Control Fault Domain 5 SQ11.1 - Install TW | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/28/26 | 11/25/26 | 25.0 | 25.0 |
|
60.0 |
RPL10.INT.NS4.02090 |
RPL10.Interior.NS4 - Control Fault Domain 6 SQ12.1 - Install TW | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/28/26 | 11/25/26 | 25.0 | 25.0 |
|
82.5 |
RPL10.INT.NS4.02820 |
RPL10.Interior.NS4 - OFE - Control Fault Domain 6 SQ12.1 (Mech Side Aisle) | OFE NS4 Control Fault Domain 6 | Not Started | 10/28/26 | 11/10/26 | 12.5 | 12.5 |
|
82.5 |
RPL10.INT.NS4.02920 |
RPL10.Interior.NS4 - Control Fault Domain 5 SQ11.1 - Install Duct (MES Side) | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/28/26 | 11/25/26 | 25.0 | 25.0 |
|
60.0 |
RPL10.INT.NS4.02940 |
RPL10.Interior.NS4 - Control Fault Domain 6 SQ12.1 - Install Duct (MES Side) | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/28/26 | 11/25/26 | 25.0 | 25.0 |
|
82.5 |
RPL10.SSBC.BB.1820 |
RPL10.Ext.Build Back.SSB-Corr - LO #1 - L2 Checklist Completion and Asset Tagging | Build Back Exterior Leave Out Wall #1 (Tent Area) | Not Started | 10/28/26 | 11/03/26 | 6.2 | 6.2 |
|
40.0 |
RPL10.W3B.FE.011541 |
RPL10.Conn EF2F<>NS4.CFD2 (P1-4) Pull Fiber Trunk (288F) [EF<>JXSW] | EF2F<>NS4.2 (P1-4) [EF<>JXSW] | Not Started | 10/28/26 | 10/30/26 | 3.8 | 3.8 |
|
40.0 |
RPL10.W3B.FE.011611 |
RPL10.Conn EF1F<>NS2.CFD2 (P2-3) Pull Fiber Trunk (384F) [EF<>SSW] | EF1F<>NS2.5 (P2-3) [EF<>SSW] | Not Started | 10/28/26 | 10/30/26 | 3.8 | 3.8 |
|
28.8 |
RPL10.W3B.FE.011656 |
RPL10.Conn EF1F<>NS4.CFD2 (P2-3) Pull Fiber Trunk (384F) [EF<>SSW] | EF1F<>NS4.2 (P2-3) [EF<>SSW] | Not Started | 10/28/26 | 10/28/26 | 1.2 | 1.2 |
|
57.5 |
RPL10.W3B.FE.011941 |
RPL10.Conn EF2B<>NS4.CFD2 (P1-4) Install Fiber Trunk (288F) [EF<>JXSW] | EF2B<>NS4.2 (P1-4) [EF<>JXSW] | Not Started | 10/28/26 | 10/30/26 | 3.8 | 3.8 |
|
37.5 |
RPL10.W3B.FE.013251 |
RPL10.Conn EF1F<>NS4.CFD1 (P2-3) Test Fiber Trunk (384F) [EF<>SSW] | EF1F<>NS4.1 (P2-3) [EF<>SSW] | Not Started | 10/28/26 | 10/29/26 | 2.5 | 2.5 |
|
57.5 |
RPL10.WP2.02060 |
RPL10.Conn GSMDF1<>NS1.CFD4 MSA Pull, Install, & Patch PON Trunks | GSMDF1 <> NS1 - MES side | Not Started | 10/28/26 | 10/29/26 | 2.5 | 2.5 |
|
32.5 |