Schedule Viewer
Last schedule upload: D3-R25005-00-RPL06 — 6139 activities — 04/16/2026 08:19 AM CT
RPL10 - GC LIVE SCHEDULE - Data Date 20260412.xer
· Uploaded Apr 16, 2026 12:51 PM
· 8408 activities
Experimental
Auto-populate checklist dates from schedule:
100
Activities Shown
0
Completed
0
In Progress
2
Critical
| Activity ID | Activity Name | WBS | Status | Start | Finish | Dur (d) | Rem (d) | % Comp | Float (d) |
|---|---|---|---|---|---|---|---|---|---|
RPL10.WP4.017340 |
RPL10.Conn NS1.CFD2.36 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install (A-End/Passive) Duplex Jumper [MA<>JXSW] | Not Started | 11/16/26 | 11/17/26 | 2.5 | 2.5 |
|
33.8 |
RPL10.WP4.017500 |
RPL10.Conn NS1.CFD2.48<>16-20 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 11/16/26 | 11/17/26 | 2.5 | 2.5 |
|
28.8 |
RPL10.WP4.021640 |
RPL10.Conn NS4.CFD1.48<>26-30 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 11/16/26 | 11/17/26 | 2.5 | 2.5 |
|
147.5 |
RPL10.WP4.023520 |
RPL10.Conn NS1.CFD6.08<>07 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 11/16/26 | 11/16/26 | 1.2 | 1.2 |
|
45.0 |
RPL10.WP4.023640 |
RPL10.Conn NS1.CFD5.14<>13 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 11/16/26 | 11/16/26 | 1.2 | 1.2 |
|
42.5 |
RPL10.WP4.023920 |
RPL10.Conn NS1.CFD3.28<>27 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 11/16/26 | 11/16/26 | 1.2 | 1.2 |
|
40.0 |
RPL10.WP4.024040 |
RPL10.Conn NS1.CFD2.34<>33 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 11/16/26 | 11/16/26 | 1.2 | 1.2 |
|
37.5 |
RPL10.WP4.024640 |
RPL10.Conn NS2.CFD5.16<>15 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 11/16/26 | 11/16/26 | 1.2 | 1.2 |
|
56.2 |
RPL10.WP4.024760 |
RPL10.Conn NS2.CFD4.22<>21 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 11/16/26 | 11/16/26 | 1.2 | 1.2 |
|
53.8 |
RPL10.WP4.031360 |
RPL10.Conn NS3.CFD3.48<>36-40 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 11/16/26 | 11/18/26 | 3.8 | 3.8 |
|
136.2 |
RPL10.WP4.031660 |
RPL10.Conn NS3.CFD5.48<>11-15 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 11/16/26 | 11/20/26 | 6.2 | 6.2 |
|
111.2 |
RPL10.WP4.07380 |
RPL10.Conn NS4.CFD3.48<>26-30 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 11/16/26 | 11/19/26 | 5.0 | 5.0 |
|
142.5 |
RPL10.WP4.07400 |
RPL10.Conn NS4.CFD3.48<>31-35 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 11/16/26 | 11/19/26 | 5.0 | 5.0 |
|
145.0 |
RPL10.WP4.07480 |
RPL10.Conn NS4.CFD4.25 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] | Pull Duplex Jumper [MA<>JXSW] | Not Started | 11/16/26 | 11/18/26 | 3.8 | 3.8 |
|
122.5 |
RPL10.WP4.07640 |
RPL10.Conn NS4.CFD4.48<>03-05 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 11/16/26 | 11/18/26 | 3.8 | 3.8 |
|
131.2 |
RPL10.WP4.07660 |
RPL10.Conn NS4.CFD4.48<>06-10 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 11/16/26 | 11/19/26 | 5.0 | 5.0 |
|
132.5 |
RPL10.WP4.07680 |
RPL10.Conn NS4.CFD4.48<>11-15 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 11/16/26 | 11/23/26 | 7.5 | 7.5 |
|
132.5 |
RPL10.WP4.NS3.01700 |
RPL10.Conn NS3.CFD2 Infrastructure - WBS Summary | Infrastructure | Not Started | 11/16/26 | 12/01/26 | 12.5 | 12.5 |
|
45.0 |
RPL10.WP4.NS3.01720 |
RPL10.Conn NS3.CFD2 Infrastructure | Infrastructure | Not Started | 11/16/26 | 12/01/26 | 12.5 | 12.5 |
|
45.0 |
RPL10.WP4.NS4.02520 |
RPL10.Conn NS4.CFD4 Infrastructure - WBS Summary | Infrastructure | Not Started | 11/16/26 | 11/19/26 | 5.0 | 5.0 |
|
67.5 |
RPL10.WP4.NS4.02540 |
RPL10.Conn NS4.CFD4 Infrastructure | Infrastructure | Not Started | 11/16/26 | 11/19/26 | 5.0 | 5.0 |
|
67.5 |
RPL10.CBL.NIDF.03070 |
RPL10.Conn NS4.CFD3 (FE) ISP Cabling - WBS Summary | FENW (Front End Network) | Not Started | 11/17/26 | 12/30/26 | 36.2 | 36.2 |
|
47.5 |
RPL10.INT.NS3.01680 |
RPL10.Interior.NS3 - Control Fault Domain 4 SQ10.2 - L2 Checklist Completion | Remaining Tie-ins post Mech Side Aisle install | Not Started | 11/17/26 | 12/16/26 | 25.0 | 25.0 |
|
66.2 |
RPL10.INT.NS3.01730 |
RPL10.Interior.NS3 - Control Fault Domain 5 SQ11.2 - Pull BMS from panel to devices | Remaining Tie-ins post Mech Side Aisle install | Not Started | 11/17/26 | 12/16/26 | 25.0 | 25.0 |
|
75.0 |
RPL10.INT.NS3.01740 |
RPL10.Interior.NS3 - Control Fault Domain 5 SQ11.2 - Pull EPMS from panel to devices | Remaining Tie-ins post Mech Side Aisle install | Not Started | 11/17/26 | 12/16/26 | 25.0 | 25.0 |
|
75.0 |
RPL10.INT.NS3.01750 |
RPL10.Interior.NS3 - Control Fault Domain 5 SQ11.2 - Set UPS and Panels (2) | Remaining Tie-ins post Mech Side Aisle install | Not Started | 11/17/26 | 12/16/26 | 25.0 | 25.0 |
|
62.5 |
RPL10.W3B.FE.011066 |
RPL10.Conn EF1B<>NS4.CFD3 (P2-3) Pull Fiber Trunk (288F) [EF<>JXSW] | EF1B<>NS4.3 (P2-3) [EF<>JXSW] | Not Started | 11/17/26 | 11/19/26 | 3.8 | 3.8 |
|
52.5 |
RPL10.W3B.FE.011146 |
RPL10.Conn EF2B<>NS4.CFD3 (P1-4) Pull Fiber Trunk (288F) [EF<>JXSW] | EF2B<>NS4.3 (P1-4) [EF<>JXSW] | Not Started | 11/17/26 | 11/19/26 | 3.8 | 3.8 |
|
42.5 |
RPL10.W3B.FE.012021 |
RPL10.Conn EF1B<>NS3.CFD1 (P2-3) Install Fiber Trunk (384F) [EF<>SSW] | EF1B<>NS3.1 (P2-3) [EF<>SSW] | Not Started | 11/17/26 | 11/18/26 | 2.5 | 2.5 |
|
38.8 |
RPL10.W3B.FE.012056 |
RPL10.Conn EF1B<>NS4.CFD2 (P2-3) Install Fiber Trunk (384F) [EF<>SSW] | EF1B<>NS4.2 (P2-3) [EF<>SSW] | Not Started | 11/17/26 | 11/18/26 | 2.5 | 2.5 |
|
37.5 |
RPL10.W3B.FE.012661 |
RPL10.Conn EF1B<>NS4.CFD2 (P2-3) Test Fiber Trunk (288F) [EF<>JXSW] | EF1B<>NS4.2 (P2-3) [EF<>JXSW] | Not Started | 11/17/26 | 11/18/26 | 2.5 | 2.5 |
|
53.8 |
RPL10.W3B.FE.013341 |
RPL10.Conn EF2F<>NS3.CFD1 (P1-4) Test Fiber Trunk (384F) [EF<>SSW] | EF2F<>NS3.1 (P1-4) [EF<>SSW] | Not Started | 11/17/26 | 11/18/26 | 2.5 | 2.5 |
|
58.8 |
RPL10.WP2.02540 |
RPL10.Conn GSMDF1<>NS4.CFD3 MSA Pull, Install, & Patch PON Trunks | GSMDF1 <> NS4 - MES side | Not Started | 11/17/26 | 11/18/26 | 2.5 | 2.5 |
|
130.0 |
RPL10.WP2.02660 |
RPL10.Conn GSMDF2<>NS4.CFD3 LVA Pull, Install, & Patch PON Trunks | GSMDF2 <> NS4 - LV side | Not Started | 11/17/26 | 11/18/26 | 2.5 | 2.5 |
|
130.0 |
RPL10.WP2.GSIDF.1840 |
RPL10.Conn IDF Huts - (GSMDF to GSIDF) NS3 N32 WBS Summary | GSIDFN32 | Not Started | 11/17/26 | 12/28/26 | 33.8 | 33.8 |
|
297.5 |
RPL10.WP2.GSIDF.1860 |
RPL10.Conn GSIDFN32 Set Infrastructure (Racks, Waterfalls etc.) | Infrastructure | Not Started | 11/17/26 | 11/23/26 | 6.2 | 6.2 |
|
48.8 |
RPL10.WP3B.FE.02520 |
RPL10.Conn EF2B<>NS4.CFD3 (P1-4) Pull/Install/Test - WBS Summary* | EF2B<>NS4.3 (P1-4) [EF<>JXSW] | Not Started | 11/17/26 | 12/04/26 | 15.0 | 15.0 |
|
51.2 |
RPL10.WP3B.FE.02600 |
RPL10.Conn EF1B<>NS4.CFD3 (P2-3) Pull/Install/Test - WBS Summary | EF1B<>NS4.3 (P2-3) [EF<>JXSW] | Not Started | 11/17/26 | 12/18/26 | 27.5 | 27.5 |
|
48.8 |
RPL10.WP4.012720 |
RPL10.Conn NS1.CFD3.30<>29 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 11/17/26 | 11/19/26 | 3.8 | 3.8 |
|
37.5 |
RPL10.WP4.012760 |
RPL10.Conn NS1.CFD3.32<>31 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 11/17/26 | 11/19/26 | 3.8 | 3.8 |
|
40.0 |
RPL10.WP4.013840 |
RPL10.Conn NS2.CFD2.38<>37 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 11/17/26 | 11/19/26 | 3.8 | 3.8 |
|
48.8 |
RPL10.WP4.013880 |
RPL10.Conn NS2.CFD2.40<>39 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 11/17/26 | 11/19/26 | 3.8 | 3.8 |
|
51.2 |
RPL10.WP4.013980 |
RPL10.Conn NS2.CFD1.45<>45 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 11/17/26 | 11/18/26 | 2.5 | 2.5 |
|
46.2 |
RPL10.WP4.014020 |
RPL10.Conn NS2.CFD1.47<>47 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 11/17/26 | 11/18/26 | 2.5 | 2.5 |
|
48.8 |
RPL10.WP4.014220 |
RPL10.Conn NS3.CFD2.09<>09 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 11/17/26 | 11/18/26 | 2.5 | 2.5 |
|
155.0 |
RPL10.WP4.014260 |
RPL10.Conn NS3.CFD2.11<>11 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 11/17/26 | 11/18/26 | 2.5 | 2.5 |
|
155.0 |
RPL10.WP4.018900 |
RPL10.Conn NS2.CFD3.31 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install (A-End/Passive) Duplex Jumper [MA<>JXSW] | Not Started | 11/17/26 | 11/18/26 | 2.5 | 2.5 |
|
51.2 |
RPL10.WP4.019060 |
RPL10.Conn NS2.CFD3.48<>31-35 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 11/17/26 | 11/18/26 | 2.5 | 2.5 |
|
46.2 |
RPL10.WP4.023660 |
RPL10.Conn NS1.CFD5.15<>15 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 11/17/26 | 11/17/26 | 1.2 | 1.2 |
|
42.5 |
RPL10.WP4.023940 |
RPL10.Conn NS1.CFD3.29<>29 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 11/17/26 | 11/17/26 | 1.2 | 1.2 |
|
40.0 |
RPL10.WP4.024060 |
RPL10.Conn NS1.CFD2.35<>35 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 11/17/26 | 11/17/26 | 1.2 | 1.2 |
|
37.5 |
RPL10.WP4.024780 |
RPL10.Conn NS2.CFD4.23<>23 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 11/17/26 | 11/17/26 | 1.2 | 1.2 |
|
53.8 |
RPL10.WP4.030500 |
RPL10.Conn NS4.CFD5.48<>21-25 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 11/17/26 | 11/20/26 | 5.0 | 5.0 |
|
108.8 |
RPL10.WP4.030700 |
RPL10.Conn NS4.CFD6.48<>21-25 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 11/17/26 | 11/20/26 | 5.0 | 5.0 |
|
108.8 |
RPL10.WP4.06900 |
RPL10.Conn NS4.CFD2.16 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] | Pull Duplex Jumper [MA<>JXSW] | Not Started | 11/17/26 | 11/19/26 | 3.8 | 3.8 |
|
147.5 |
RPL10.WP4.07140 |
RPL10.Conn NS4.CFD3.18 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] | Pull Duplex Jumper [MA<>JXSW] | Not Started | 11/17/26 | 11/19/26 | 3.8 | 3.8 |
|
125.0 |
RPL10.WP4.07420 |
RPL10.Conn NS4.CFD3.48<>36-40 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 11/17/26 | 11/19/26 | 3.8 | 3.8 |
|
147.5 |
RPL10.WP4.07700 |
RPL10.Conn NS4.CFD4.48<>16-20 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 11/17/26 | 11/23/26 | 6.2 | 6.2 |
|
135.0 |
RPL10.WP4.07720 |
RPL10.Conn NS4.CFD4.48<>21-25 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 11/17/26 | 11/23/26 | 6.2 | 6.2 |
|
137.5 |
RPL10.WP4.08620 |
RPL10.Conn NS1.CFD1.46<>46 Pull/Install Ext. Trunk (192F) [MA<>EB] | [MA<>EB] | Not Started | 11/17/26 | 11/18/26 | 2.5 | 2.5 |
|
0.0 |
RPL10.WP4.NS2.02720 |
RPL10.Conn NS2.CFD4 Network Suite Management and Console In - Rack Fanout - PON | Post ORv3 Rack | Not Started | 11/17/26 | 11/30/26 | 10.0 | 10.0 |
|
6.2 |
RPL10.CBL.NIDF.03190 |
RPL10.Conn NS3.CFD2 (FE) ISP Cabling - WBS Summary | FENW (Front End Network) | Not Started | 11/18/26 | 12/28/26 | 32.5 | 32.5 |
|
52.5 |
RPL10.CX.NS2.01220 |
RPL10.CX.NS2 - L3/L4 - Remaining Electrical Equipment (Fire Alarm, Security, Lighting) | NS2 ELECTRICAL | Not Started | 11/18/26 | 12/10/26 | 18.8 | 18.8 |
|
12.5 |
RPL10.W3B.FE.011121 |
RPL10.Conn EF2B<>NS3.CFD2 (P1-4) Pull Fiber Trunk (288F) [EF<>JXSW] | EF2B<>NS3.2 (P1-4) [EF<>JXSW] | Not Started | 11/18/26 | 11/19/26 | 2.5 | 2.5 |
|
37.5 |
RPL10.W3B.FE.012236 |
RPL10.Conn EF1F<>NS2.CFD2 (P2-3) Install Fiber Trunk (288F) [EF<>JXSW] | EF1F<>NS2.5 (P2-3) [EF<>JXSW] | Not Started | 11/18/26 | 11/20/26 | 3.8 | 3.8 |
|
11.2 |
RPL10.W3B.FE.012811 |
RPL10.Conn EF1B<>NS2.CFD2 (P2-3) Test Fiber Trunk (384F) [EF<>SSW] | EF1B<>NS2.5 (P2-3) [EF<>SSW] | Not Started | 11/18/26 | 11/19/26 | 2.5 | 2.5 |
|
12.5 |
RPL10.WP3B.FE.08200 |
RPL10.Conn EF2B<>NS3.CFD2 (P1-4) Pull/Install/Test - WBS Summary* | EF2B<>NS3.2 (P1-4) [EF<>JXSW] | Not Started | 11/18/26 | 12/01/26 | 10.0 | 10.0 |
|
57.5 |
RPL10.WP4.010040 |
RPL10.Conn NS2.CFD3 Pull/Install Trunk (384F) [RSW<>FSW] | Pull/Install Trunk & Multidrop Cable | Not Started | 11/18/26 | 11/30/26 | 8.8 | 8.8 |
|
25.0 |
RPL10.WP4.013020 |
RPL10.Conn NS1.CFD1.45<>45 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 11/18/26 | 11/20/26 | 3.8 | 3.8 |
|
32.5 |
RPL10.WP4.013060 |
RPL10.Conn NS1.CFD1.47<>47 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 11/18/26 | 11/20/26 | 3.8 | 3.8 |
|
35.0 |
RPL10.WP4.017360 |
RPL10.Conn NS1.CFD2.37 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install (A-End/Passive) Duplex Jumper [MA<>JXSW] | Not Started | 11/18/26 | 11/19/26 | 2.5 | 2.5 |
|
33.8 |
RPL10.WP4.017520 |
RPL10.Conn NS1.CFD2.48<>21-25 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 11/18/26 | 11/19/26 | 2.5 | 2.5 |
|
28.8 |
RPL10.WP4.017640 |
RPL10.Conn NS1.CFD1.48<>03-05 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 11/18/26 | 11/19/26 | 2.5 | 2.5 |
|
18.8 |
RPL10.WP4.021660 |
RPL10.Conn NS4.CFD1.48<>31-35 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 11/18/26 | 11/19/26 | 2.5 | 2.5 |
|
147.5 |
RPL10.WP4.023680 |
RPL10.Conn NS1.CFD5.16<>15 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 11/18/26 | 11/18/26 | 1.2 | 1.2 |
|
42.5 |
RPL10.WP4.023800 |
RPL10.Conn NS1.CFD4.22<>21 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 11/18/26 | 11/18/26 | 1.2 | 1.2 |
|
40.0 |
RPL10.WP4.024080 |
RPL10.Conn NS1.CFD2.36<>35 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 11/18/26 | 11/18/26 | 1.2 | 1.2 |
|
37.5 |
RPL10.WP4.024200 |
RPL10.Conn NS1.CFD1.42<>41 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 11/18/26 | 11/18/26 | 1.2 | 1.2 |
|
35.0 |
RPL10.WP4.024800 |
RPL10.Conn NS2.CFD4.24<>23 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 11/18/26 | 11/18/26 | 1.2 | 1.2 |
|
53.8 |
RPL10.WP4.024820 |
RPL10.Conn NS2.CFD3.25<>25 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 11/18/26 | 11/18/26 | 1.2 | 1.2 |
|
45.0 |
RPL10.WP4.031500 |
RPL10.Conn NS3.CFD4.48<>21-25 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 11/18/26 | 11/23/26 | 5.0 | 5.0 |
|
120.0 |
RPL10.WP4.032980 |
RPL10.Conn NS2.CFD3.25 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install Duplex Jumper [MA<>JXSW] | Not Started | 11/18/26 | 11/19/26 | 2.5 | 2.5 |
|
35.0 |
RPL10.WP4.04960 |
RPL10.Conn NS3.CFD2.11 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] | Pull Duplex Jumper [MA<>JXSW] | Not Started | 11/18/26 | 11/20/26 | 3.8 | 3.8 |
|
140.0 |
RPL10.WP4.07440 |
RPL10.Conn NS4.CFD3.48<>41-44 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 11/18/26 | 11/19/26 | 2.5 | 2.5 |
|
150.0 |
RPL10.WP4.07740 |
RPL10.Conn NS4.CFD4.48<>26-30 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 11/18/26 | 11/23/26 | 5.0 | 5.0 |
|
140.0 |
RPL10.WP4.07760 |
RPL10.Conn NS4.CFD4.48<>31-35 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 11/18/26 | 11/23/26 | 5.0 | 5.0 |
|
142.5 |
RPL10.WP4.09260 |
RPL10.Conn NS2.CFD3 Pull/Install Trunk (192F) [FSW<>SSW] | Pull/Install Trunk & Multidrop Cable | Not Started | 11/18/26 | 11/25/26 | 7.5 | 7.5 |
|
47.5 |
RPL10.WP4.NS2.03580 |
RPL10.Conn NS2.CFD2 - Install ORv3 | OFE - Passive In-row Racks, Racks (ORv3Ns, MCRs) & PON | Not Started | 11/18/26 | 11/30/26 | 8.8 | 8.8 |
|
-43.8 |
RPL10.WP4.NS2.03600 |
RPL10.Conn NS2.CFD2 - Deliver & Assemble - PON | OFE - Passive In-row Racks, Racks (ORv3Ns, MCRs) & PON | Not Started | 11/18/26 | 11/30/26 | 8.8 | 8.8 |
|
26.2 |
RPL10.WP4.NS4.01480 |
RPL10.Conn NS4.CFD3 Infrastructure - WBS Summary | Infrastructure | Not Started | 11/18/26 | 12/03/26 | 12.5 | 12.5 |
|
45.0 |
RPL10.WP4.NS4.01500 |
RPL10.Conn NS4.CFD3 Infrastructure | Infrastructure | Not Started | 11/18/26 | 12/03/26 | 12.5 | 12.5 |
|
45.0 |
GCD.RPL10.6145 |
L3/L4 Finish SSB - RPL10 | SSB | Not Started | 11/19/26 | 11/19/26 | 0.0 | 0.0 |
|
327.5 |
RPL10.CX.NS2.01210 |
RPL10.CX.NS2 - L3/L4 - Remaining Mechanical Equipment (CU/CRAH) | NS2 MECHANICAL | Not Started | 11/19/26 | 12/18/26 | 25.0 | 25.0 |
|
12.5 |
RPL10.ENDC.BB.1520 |
RPL10.Int.Build Back.End-Corr - LO #10 - MEPF - On-Wall, OH, Lowside, Lights | Build Back Interior Leave Out Wall #10 (End Corr) | Not Started | 11/19/26 | 12/11/26 | 18.8 | 18.8 |
|
117.5 |
RPL10.ENDC.BB.3310 |
RPL10.Ext.Build Back.End-Corr - LO #4 - Install Waterproofing and Flashing | Build Back Exterior Leave Out Wall #4 (Tent Area) | Not Started | 11/19/26 | 11/23/26 | 3.8 | 3.8 |
|
92.5 |
RPL10.EY.EF2.01400 |
RPL10.EY.EF2 - Install RPL-5 FSP Decking and Detailing Turnover | Fiber Support Platform - RPL-5 | Not Started | 11/19/26 | 12/04/26 | 12.5 | 12.5 |
|
78.8 |
RPL10.EY.NS4.01360 |
RPL10.EY.NS4 - Demo of Tent | Tent and Temp Conditions | Not Started | 11/19/26 | 12/04/26 | 12.5 | 12.5 |
|
83.8 |
RPL10.INT.NS3.02820 |
RPL10.Interior.NS3 - OFE - Control Fault Domain 6 SQ12.2 (HAC) | OFE NS3 Control Fault Domain 6 | Not Started | 11/19/26 | 12/04/26 | 12.5 | 12.5 |
|
67.5 |
RPL10.W3B.FE.012261 |
RPL10.Conn EF1F<>NS4.CFD2 (P2-3) Install Fiber Trunk (288F) [EF<>JXSW] | EF1F<>NS4.2 (P2-3) [EF<>JXSW] | Not Started | 11/19/26 | 11/23/26 | 3.8 | 3.8 |
|
37.5 |
RPL10.W3B.FE.012421 |
RPL10.Conn EF1F<>NS3.CFD1 (P2-3) Install Fiber Trunk (384F) [EF<>SSW] | EF1F<>NS3.1 (P2-3) [EF<>SSW] | Not Started | 11/19/26 | 11/20/26 | 2.5 | 2.5 |
|
38.8 |