Schedule Viewer

Last schedule upload: D3-R25005-00-RPL06 — 6139 activities — 04/16/2026 08:19 AM CT
RPL10 - GC LIVE SCHEDULE - Data Date 20260412.xer · Uploaded Apr 16, 2026 12:51 PM · 8408 activities
Experimental Auto-populate checklist dates from schedule:
Clear
100
Activities Shown
0
Completed
0
In Progress
3
Critical
Activity ID Activity Name WBS Status Start Finish Dur (d) Rem (d) % Comp Float (d)
RPL10.WP4.NS4.01700 RPL10.Conn NS4.CFD4 Network - WBS Summary Network Not Started 12/15/26 03/25/27 86.2 86.2
0%
35.0
RPL10.WP4.NS4.01720 RPL10.Conn NS4.CFD4 Network Suite [JXSW<>MA] Trunks Pre ORv3 Rack Not Started 12/15/26 12/24/26 10.0 10.0
0%
61.2
GCD.RPL10.5085 L3/L4 Finish - NS4 Rows 9-16 NS Not Started 12/16/26 12/16/26 0.0 0.0
0%
117.5
RPL10.CBL.NIDF.03270 RPL10.Conn NS3.CFD4 (FE) ISP Cabling - WBS Summary FENW (Front End Network) Not Started 12/16/26 02/25/27 60.0 60.0
0%
42.5
RPL10.CX.NS4.01580 RPL10.CX.NS4 - L3/L4 - Control Fault Domain 4 - TW Flush and Fill NS4 Control Fault Domain 4 Not Started 12/16/26 12/28/26 10.0 10.0
0%
66.2
RPL10.W3B.FE.011131 RPL10.Conn EF2B<>NS3.CFD4 (P1-4) Pull Fiber Trunk (288F) [EF<>JXSW] EF2B<>NS3.4 (P1-4) [EF<>JXSW] Not Started 12/16/26 12/18/26 3.8 3.8
0%
66.2
RPL10.W3B.FE.012826 RPL10.Conn EF1B<>NS3.CFD2 (P2-3) Test Fiber Trunk (384F) [EF<>SSW] EF1B<>NS3.2 (P2-3) [EF<>SSW] Not Started 12/16/26 12/17/26 2.5 2.5
0%
55.0
RPL10.WP3B.FE.08520 RPL10.Conn EF2B<>NS3.CFD4 (P1-4) Pull/Install/Test - WBS Summary* EF2B<>NS3.4 (P1-4) [EF<>JXSW] Not Started 12/16/26 02/01/27 38.8 38.8
0%
46.2
RPL10.WP4.017820 RPL10.Conn NS1.CFD1.48<>46-49 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] Install (A-End/Passive) Duplex Jumper [RSW<>FSW] Not Started 12/16/26 12/17/26 2.5 2.5
0%
18.8
RPL10.WP4.021840 RPL10.Conn NS4.CFD2.14 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] Install (A-End/Passive) Duplex Jumper [MA<>JXSW] Not Started 12/16/26 12/17/26 2.5 2.5
0%
127.5
RPL10.WP4.022000 RPL10.Conn NS4.CFD2.48<>26-30 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] Install (A-End/Passive) Duplex Jumper [RSW<>FSW] Not Started 12/16/26 12/17/26 2.5 2.5
0%
122.5
RPL10.WP4.025220 RPL10.Conn NS2.CFD1.45<>45 Install Simplex Jumper at Z- End (SC<>LC) [PON] Install Simplex Jumper [PON] Not Started 12/16/26 12/16/26 1.2 1.2
0%
27.5
RPL10.WP4.026320 RPL10.Conn NS4.CFD1.04<>03 Install Simplex Jumper at Z- End (SC<>LC) [PON] Install Simplex Jumper [PON] Not Started 12/16/26 12/16/26 1.2 1.2
0%
128.8
RPL10.WP4.031760 RPL10.Conn NS3.CFD5.48<>36-40 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] Prefab Not Started 12/16/26 12/18/26 3.8 3.8
0%
111.2
RPL10.WP4.031880 RPL10.Conn NS3.CFD6.48<>16-20 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] Prefab Not Started 12/16/26 12/21/26 5.0 5.0
0%
92.5
RPL10.WP4.05860 RPL10.Conn NS3.CFD4.48<>16-20 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/16/26 12/21/26 5.0 5.0
0%
125.0
RPL10.WP4.05880 RPL10.Conn NS3.CFD4.48<>21-25 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/16/26 12/21/26 5.0 5.0
0%
127.5
RPL10.WP4.05900 RPL10.Conn NS3.CFD4.48<>26-30 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/16/26 12/21/26 5.0 5.0
0%
130.0
RPL10.WP4.05920 RPL10.Conn NS3.CFD4.48<>31-35 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/16/26 12/21/26 5.0 5.0
0%
132.5
RPL10.WP4.08100 RPL10.Conn NS4.CFD5.48<>26-30 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/16/26 12/21/26 5.0 5.0
0%
117.5
RPL10.WP4.08120 RPL10.Conn NS4.CFD5.48<>31-35 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/16/26 12/21/26 5.0 5.0
0%
120.0
RPL10.WP4.08300 RPL10.Conn NS4.CFD6.48<>26-30 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/16/26 12/21/26 5.0 5.0
0%
117.5
RPL10.WP4.08320 RPL10.Conn NS4.CFD6.48<>31-35 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/16/26 12/21/26 5.0 5.0
0%
120.0
RPL10.WP4.NS2.02880 RPL10.Conn NS2.CFD3 Network Suite Management and Console In - Row Cabling - PON Post ORv3 Rack Not Started 12/16/26 12/28/26 10.0 10.0
0%
-2.5
RPL10.WP4.NS3.02160 RPL10.Conn NS3.CFD3 Network - WBS Summary Network Not Started 12/16/26 03/02/27 63.8 63.8
0%
43.8
RPL10.WP4.NS3.02180 RPL10.Conn NS3.CFD3 Network Suite [JXSW<>MA] Trunks Pre ORv3 Rack Not Started 12/16/26 12/28/26 10.0 10.0
0%
47.5
RPL10.WP4.NS3.02560 RPL10.Conn NS3.CFD4 Infrastructure - WBS Summary Infrastructure Not Started 12/16/26 12/30/26 12.5 12.5
0%
60.0
RPL10.WP4.NS3.02580 RPL10.Conn NS3.CFD4 Infrastructure Infrastructure Not Started 12/16/26 12/30/26 12.5 12.5
0%
60.0
RPL10.WP4.NS4.01240 RPL10.Conn NS4.CFD1 GSMDF <> Network Suites Management Trunks Post ORv3 Rack Not Started 12/16/26 12/18/26 3.8 3.8
0%
43.8
RPL10.WP4.NS4.01560 RPL10.Conn NS4.CFD3 Network Suite [JXSW<>MA] Multi Drop Cable Pre ORv3 Rack Not Started 12/16/26 12/28/26 10.0 10.0
0%
45.0
RPL10.CBL.NIDF.03290 RPL10.Conn NS4.CFD5 (FE) ISP Cabling - WBS Summary FENW (Front End Network) Not Started 12/17/26 03/01/27 61.2 61.2
0%
37.5
RPL10.Conn.MS.01650 RPL10.Conn NS2.CFD3 FIM NS2 Not Started 12/17/26 01/15/27 25.0 25.0
0%
12.5
RPL10.Conn.MS.01970 RPL10.Conn NS1.CFD1 FIM NS1 Not Started 12/17/26 01/15/27 25.0 25.0
0%
1.2
RPL10.EY.EF2.01480 RPL10.EY.EF2 - Install RPL-5 FSP Roofing Final Roof Fiber Support Platform - RPL-5 Not Started 12/17/26 12/31/26 12.5 12.5
0%
78.8
RPL10.EY.NS4.01400 RPL10.EY.NS4 - Cure for Remaining Equipment Pads (High Early Mix) Build Back Exterior Leave Out Wall #4 (Tent Area) Not Started 12/17/26 12/23/26 8.8 8.8
0%
126.2
RPL10.EY.SSB.01360 RPL10.EY.SSB - Install Landscaping Hardscape and Landscape Not Started 12/17/26 01/08/27 18.8 18.8
0%
287.5
RPL10.INT.NS3.01820 RPL10.Interior.NS3 - Control Fault Domain 5 SQ11.2 - L2 Checklist Completion Remaining Tie-ins post Mech Side Aisle install Not Started 12/17/26 01/15/27 25.0 25.0
0%
56.2
RPL10.INT.NS3.01910 RPL10.Interior.NS3 - Control Fault Domain 6 SQ12.2 - Install Mechanical Side Aisle Cable Tray Remaining Tie-ins post Mech Side Aisle install Not Started 12/17/26 01/15/27 25.0 25.0
0%
81.2
RPL10.INT.NS3.01930 RPL10.Interior.NS3 - Control Fault Domain 6 SQ12.2 - Install copper from GS.IDF to BMS and EPMS panels (UG from Corr IDF Remaining Tie-ins post Mech Side Aisle install Not Started 12/17/26 01/15/27 25.0 25.0
0%
67.5
RPL10.OFCI.7400 OFCI - Delivery ROJ: BE Fiber for CFD NS1.1 (ROJ ) (RVCD ) NS1 Not Started 12/17/26 01/08/27 18.8 18.8
0%
0.0
RPL10.W3B.FE.011076 RPL10.Conn EF1B<>NS4.CFD5 (P2-3) Pull Fiber Trunk (288F) [EF<>JXSW] EF1B<>NS4.5 (P2-3) [EF<>JXSW] Not Started 12/17/26 12/22/26 5.0 5.0
0%
77.5
RPL10.W3B.FE.011626 RPL10.Conn EF1F<>NS3.CFD2 (P2-3) Pull Fiber Trunk (384F) [EF<>SSW] EF1F<>NS3.2 (P2-3) [EF<>SSW] Not Started 12/17/26 12/21/26 3.8 3.8
0%
37.5
RPL10.W3B.FE.011786 RPL10.Conn EF2F<>NS4.CFD4 (P1-4) Pull Fiber Trunk (384F) [EF<>SSW] EF2F<>NS4.4 (P1-4) [EF<>SSW] Not Started 12/17/26 12/18/26 2.5 2.5
0%
53.8
RPL10.W3B.FE.012061 RPL10.Conn EF1B<>NS4.CFD3 (P2-3) Install Fiber Trunk (384F) [EF<>SSW] EF1B<>NS4.3 (P2-3) [EF<>SSW] Not Started 12/17/26 12/18/26 2.5 2.5
0%
37.5
RPL10.W3B.FE.012241 RPL10.Conn EF1F<>NS3.CFD2 (P2-3) Install Fiber Trunk (288F) [EF<>JXSW] EF1F<>NS3.2 (P2-3) [EF<>JXSW] Not Started 12/17/26 12/21/26 3.8 3.8
0%
37.5
RPL10.W3B.FE.012666 RPL10.Conn EF1B<>NS4.CFD3 (P2-3) Test Fiber Trunk (288F) [EF<>JXSW] EF1B<>NS4.3 (P2-3) [EF<>JXSW] Not Started 12/17/26 12/18/26 2.5 2.5
0%
48.8
RPL10.WP2.02580 RPL10.Conn GSMDF1<>NS4.CFD5 MSA Pull, Install, & Patch PON Trunks GSMDF1 <> NS4 - MES side Not Started 12/17/26 12/18/26 2.5 2.5
0%
110.0
RPL10.WP2.02700 RPL10.Conn GSMDF2<>NS4.CFD5 LVA Pull, Install, & Patch PON Trunks GSMDF2 <> NS4 - LV side Not Started 12/17/26 12/18/26 2.5 2.5
0%
110.0
RPL10.WP3B.FE.02700 RPL10.Conn EF2F<>NS4.CFD4 (P1-4) Pull/Install/Test - WBS Summary EF2F<>NS4.4 (P1-4) [EF<>SSW] Not Started 12/17/26 01/14/27 23.8 23.8
0%
45.0
RPL10.WP3B.FE.08300 RPL10.Conn EF1F<>NS3.CFD2 (P2-3) Pull/Install/Test - WBS Summary* EF1F<>NS3.2 (P2-3) [EF<>SSW] Not Started 12/17/26 12/28/26 8.8 8.8
0%
52.5
RPL10.WP3B.FE.09440 RPL10.Conn EF1B<>NS4.CFD5 (P2-3) Pull/Install/Test - WBS Summary EF1B<>NS4.5 (P2-3) [EF<>JXSW] Not Started 12/17/26 02/18/27 52.5 52.5
0%
38.8
RPL10.WP4.011640 RPL10.Conn NS1.CFD1 Pull/Install In-Row Trunk (24F) [EB<>DR] [EB<>DR] Not Started 12/17/26 12/18/26 2.5 2.5
0%
0.0
RPL10.WP4.014540 RPL10.Conn NS3.CFD4.25<>25 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] Pull Simplex Jumper [PON] Not Started 12/17/26 12/18/26 2.5 2.5
0%
130.0
RPL10.WP4.014580 RPL10.Conn NS3.CFD4.27<>27 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] Pull Simplex Jumper [PON] Not Started 12/17/26 12/18/26 2.5 2.5
0%
130.0
RPL10.WP4.019260 RPL10.Conn NS2.CFD2.39 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] Install (A-End/Passive) Duplex Jumper [MA<>JXSW] Not Started 12/17/26 12/18/26 2.5 2.5
0%
26.2
RPL10.WP4.019420 RPL10.Conn NS2.CFD2.48<>31-35 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] Install (A-End/Passive) Duplex Jumper [RSW<>FSW] Not Started 12/17/26 12/18/26 2.5 2.5
0%
21.2
RPL10.WP4.019540 RPL10.Conn NS2.CFD1.48<>11-15 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] Install (A-End/Passive) Duplex Jumper [RSW<>FSW] Not Started 12/17/26 12/18/26 2.5 2.5
0%
11.2
RPL10.WP4.019840 RPL10.Conn NS3.CFD1.48<>36-40 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] Install (A-End/Passive) Duplex Jumper [RSW<>FSW] Not Started 12/17/26 12/18/26 2.5 2.5
0%
138.8
RPL10.WP4.025240 RPL10.Conn NS2.CFD1.46<>45 Install Simplex Jumper at Z- End (SC<>LC) [PON] Install Simplex Jumper [PON] Not Started 12/17/26 12/17/26 1.2 1.2
0%
27.5
RPL10.WP4.026340 RPL10.Conn NS4.CFD1.05<>05 Install Simplex Jumper at Z- End (SC<>LC) [PON] Install Simplex Jumper [PON] Not Started 12/17/26 12/17/26 1.2 1.2
0%
128.8
RPL10.WP4.033260 RPL10.Conn NS2.CFD2.39 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] Install Duplex Jumper [MA<>JXSW] Not Started 12/17/26 12/18/26 2.5 2.5
0%
26.2
RPL10.WP4.05380 RPL10.Conn NS3.CFD3.22 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] Pull Duplex Jumper [MA<>JXSW] Not Started 12/17/26 12/21/26 3.8 3.8
0%
127.5
RPL10.WP4.05940 RPL10.Conn NS3.CFD4.48<>36-40 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/17/26 12/21/26 3.8 3.8
0%
135.0
RPL10.WP4.07620 RPL10.Conn NS4.CFD4.32 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] Pull Duplex Jumper [MA<>JXSW] Not Started 12/17/26 12/21/26 3.8 3.8
0%
122.5
RPL10.WP4.07860 RPL10.Conn NS4.CFD5.34 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] Pull Duplex Jumper [MA<>JXSW] Not Started 12/17/26 12/21/26 3.8 3.8
0%
100.0
RPL10.WP4.08140 RPL10.Conn NS4.CFD5.48<>36-40 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/17/26 12/21/26 3.8 3.8
0%
122.5
RPL10.WP4.08340 RPL10.Conn NS4.CFD6.48<>36-40 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/17/26 12/21/26 3.8 3.8
0%
122.5
GCD.RPL10.5405 L3/L4 Start - NS3 Rows 25-32 NS Not Started 12/18/26 12/18/26 0.0 0.0
0%
128.8
RPL10.CX.NS3.01140 RPL10.CX.NS3 - L3/L4 - Elec. Domain 07/08 NS3 ELECTRICAL Not Started 12/18/26 12/23/26 5.0 5.0
0%
66.2
RPL10.ENDC.BB.1140 RPL10.Ext.Build Back.End-Corr - LO #3 - Install IMP Exterior Panel Build Back Exterior Leave Out Wall #3 (Tent Area) Not Started 12/18/26 12/21/26 2.5 2.5
0%
72.5
RPL10.WP4.021860 RPL10.Conn NS4.CFD2.15 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] Install (A-End/Passive) Duplex Jumper [MA<>JXSW] Not Started 12/18/26 12/21/26 2.5 2.5
0%
127.5
RPL10.WP4.022020 RPL10.Conn NS4.CFD2.48<>31-35 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] Install (A-End/Passive) Duplex Jumper [RSW<>FSW] Not Started 12/18/26 12/21/26 2.5 2.5
0%
122.5
RPL10.WP4.025260 RPL10.Conn NS2.CFD1.47<>47 Install Simplex Jumper at Z- End (SC<>LC) [PON] Install Simplex Jumper [PON] Not Started 12/18/26 12/18/26 1.2 1.2
0%
27.5
RPL10.WP4.026360 RPL10.Conn NS4.CFD1.06<>05 Install Simplex Jumper at Z- End (SC<>LC) [PON] Install Simplex Jumper [PON] Not Started 12/18/26 12/18/26 1.2 1.2
0%
128.8
RPL10.WP4.05680 RPL10.Conn NS3.CFD4.27 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] Pull Duplex Jumper [MA<>JXSW] Not Started 12/18/26 12/22/26 3.8 3.8
0%
115.0
RPL10.WP4.05960 RPL10.Conn NS3.CFD4.48<>41-44 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/18/26 12/21/26 2.5 2.5
0%
135.0
RPL10.WP4.08160 RPL10.Conn NS4.CFD5.48<>41-44 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/18/26 12/21/26 2.5 2.5
0%
125.0
RPL10.WP4.08360 RPL10.Conn NS4.CFD6.48<>41-44 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/18/26 12/21/26 2.5 2.5
0%
125.0
RPL10.WP4.NS4.02920 RPL10.Conn NS4.CFD5 Infrastructure - WBS Summary Infrastructure Not Started 12/18/26 01/04/27 12.5 12.5
0%
60.0
RPL10.WP4.NS4.02960 RPL10.Conn NS4.CFD5 Infrastructure Infrastructure Not Started 12/18/26 01/04/27 12.5 12.5
0%
60.0
RPL10.WP4.NS4.03400 RPL10.Conn NS4.CFD6 Infrastructure - WBS Summary Infrastructure Not Started 12/18/26 01/04/27 12.5 12.5
0%
97.5
RPL10.WP4.NS4.03440 RPL10.Conn NS4.CFD6 Infrastructure Infrastructure Not Started 12/18/26 01/04/27 12.5 12.5
0%
97.5
RPL10.CX.NS2.01230 RPL10.CX.NS2 - L4 - Data Hall Level Testing NS2 DATA HALL LEVEL TESTING Not Started 12/21/26 01/05/27 12.5 12.5
0%
12.5
RPL10.Conn.MS.01370 RPL10.Conn NS3.CFD1 FIM NS3 Not Started 12/21/26 01/20/27 25.0 25.0
0%
125.0
RPL10.ENDC.BB.1960 RPL10.Int.Build Back.End-Corr - LO #10 - Final Clean Build Back Interior Leave Out Wall #10 (End Corr) Not Started 12/21/26 12/24/26 5.0 5.0
0%
117.5
RPL10.EY.NS4.01390 RPL10.EY.NS4 - Install Remaning EY Paving Hardscape and Landscape Not Started 12/21/26 12/28/26 6.2 6.2
0%
127.5
RPL10.W3B.FE.011156 RPL10.Conn EF2B<>NS4.CFD5 (P1-4) Pull Fiber Trunk (288F) [EF<>JXSW] EF2B<>NS4.5 (P1-4) [EF<>JXSW] Not Started 12/21/26 12/24/26 5.0 5.0
0%
61.2
RPL10.W3B.FE.011356 RPL10.Conn EF2B<>NS3.CFD4 (P1-4) Pull Fiber Trunk (384F) [EF<>SSW] EF2B<>NS3.4 (P1-4) [EF<>SSW] Not Started 12/21/26 12/22/26 2.5 2.5
0%
66.2
RPL10.W3B.FE.012266 RPL10.Conn EF1F<>NS4.CFD3 (P2-3) Install Fiber Trunk (288F) [EF<>JXSW] EF1F<>NS4.3 (P2-3) [EF<>JXSW] Not Started 12/21/26 12/23/26 3.8 3.8
0%
37.5
RPL10.W3B.FE.012861 RPL10.Conn EF1B<>NS4.CFD3 (P2-3) Test Fiber Trunk (384F) [EF<>SSW] EF1B<>NS4.3 (P2-3) [EF<>SSW] Not Started 12/21/26 12/22/26 2.5 2.5
0%
48.8
RPL10.WP2.02600 RPL10.Conn GSMDF1<>NS4.CFD6 MSA Pull, Install, & Patch PON Trunks GSMDF1 <> NS4 - MES side Not Started 12/21/26 12/22/26 2.5 2.5
0%
110.0
RPL10.WP2.02720 RPL10.Conn GSMDF2<>NS4.CFD6 LVA Pull, Install, & Patch PON Trunks GSMDF2 <> NS4 - LV side Not Started 12/21/26 12/22/26 2.5 2.5
0%
110.0
RPL10.WP3B.FE.08560 RPL10.Conn EF2B<>NS3.CFD4 (P1-4) Pull/Install/Test - WBS Summary EF2B<>NS3.4 (P1-4) [EF<>SSW] Not Started 12/21/26 02/03/27 37.5 37.5
0%
46.2
RPL10.WP3B.FE.09420 RPL10.Conn EF2B<>NS4.CFD5 (P1-4) Pull/Install/Test - WBS Summary* EF2B<>NS4.5 (P1-4) [EF<>JXSW] Not Started 12/21/26 02/03/27 37.5 37.5
0%
41.2
RPL10.WP4.010140 RPL10.Conn NS3.CFD1 Pull/Install Trunk (384F) [RSW<>FSW] Pull/Install Trunk Not Started 12/21/26 12/30/26 8.8 8.8
0%
125.0
RPL10.WP4.014560 RPL10.Conn NS3.CFD4.26<>25 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] Pull Simplex Jumper [PON] Not Started 12/21/26 12/23/26 3.8 3.8
0%
130.0
RPL10.WP4.014600 RPL10.Conn NS3.CFD4.28<>27 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] Pull Simplex Jumper [PON] Not Started 12/21/26 12/23/26 3.8 3.8
0%
130.0
RPL10.WP4.015660 RPL10.Conn NS4.CFD5.33<>33 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] Pull Simplex Jumper [PON] Not Started 12/21/26 12/23/26 3.8 3.8
0%
112.5
RPL10.WP4.015700 RPL10.Conn NS4.CFD5.35<>35 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] Pull Simplex Jumper [PON] Not Started 12/21/26 12/23/26 3.8 3.8
0%
112.5
RPL10.WP4.019280 RPL10.Conn NS2.CFD2.40 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] Install (A-End/Passive) Duplex Jumper [MA<>JXSW] Not Started 12/21/26 12/22/26 2.5 2.5
0%
26.2