Schedule Viewer
Last schedule upload: D3-R25005-00-RPL06 — 6139 activities — 04/16/2026 08:19 AM CT
RPL09 - GC LIVE SCHEDULE - Data Date 2026.04.12.xer
· Uploaded Apr 16, 2026 01:12 PM
· 5201 activities
Experimental
Auto-populate checklist dates from schedule:
100
Activities Shown
0
Completed
0
In Progress
0
Critical
| Activity ID | Activity Name | WBS | Status | Start | Finish | Dur (d) | Rem (d) | % Comp | Float (d) |
|---|---|---|---|---|---|---|---|---|---|
RPL09.INT.EC.LO.8940 |
RPL09.Interior.EC LO #14 - Install Fire Life Safety Lowside OH | Interior Leave Out Wall #14 DHD/EC for DHB&D HACs | Not Started | 10/04/27 | 10/06/27 | 3.8 | 3.8 |
|
156.2 |
RPL09.INT.EC.LO.8960 |
RPL09.Interior.EC LO #14 - Install Plumbing Lowside OH | Interior Leave Out Wall #14 DHD/EC for DHB&D HACs | Not Started | 10/04/27 | 10/06/27 | 3.8 | 3.8 |
|
151.2 |
RPL09.OFCI.C.4300 |
OFCI Delivery: FE Fiber for CFD C.1 (ROJ ) (RVCD ) | Data Hall C | Not Started | 10/04/27 | 10/08/27 | 6.2 | 6.2 |
|
210.0 |
RPL09.SKN.E.LO.02080 |
RPL09.SKIN.LO#18 - Install IMP Insulated Metal Panels | Build back Exterior Leave Out Walls #18 (EC - North) | Not Started | 10/04/27 | 10/05/27 | 2.5 | 2.5 |
|
138.8 |
RPL09.WP3B.011700 |
RPL09.Conn EF1<>DHD.31 Pull Pigtails (384F) P1&4 (MES) | EF1<>DHD.31 | Not Started | 10/04/27 | 10/05/27 | 2.5 | 2.5 |
|
216.2 |
RPL09.WP3B.011860 |
RPL09.Conn EF2<>DHA.03 Pull Pigtails (384F) P2&3 (MES) | EF2<>DHA.03 | Not Started | 10/04/27 | 10/05/27 | 2.5 | 2.5 |
|
131.2 |
RPL09.WP3B.012420 |
RPL09.Conn EF2<>DHD.31 Pull Pigtails (384F) P2&3 (LV) | EF2<>DHD.31 | Not Started | 10/04/27 | 10/04/27 | 1.2 | 1.2 |
|
218.8 |
RPL09.WP3B.013280 |
RPL09.Conn EF2<>DHA.02 Install (A-End) Pigtails (384F) P2&3 (MES) | EF2<>DHA.02 | Not Started | 10/04/27 | 10/04/27 | 1.2 | 1.2 |
|
145.0 |
RPL09.WP3B.017220 |
RPL09.Conn EF1<>DHB.19 Test Pigtails (384F) P1&4 (MES) | EF1<>DHB.19 | Not Started | 10/04/27 | 10/05/27 | 2.5 | 2.5 |
|
142.5 |
RPL09.WP4.021640 |
RPL09.Conn DHA.09 Pull Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 10/04/27 | 10/04/27 | 1.2 | 1.2 |
|
155.0 |
RPL09.WP4.021660 |
RPL09.Conn DHA.10 Pull Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 10/04/27 | 10/04/27 | 1.2 | 1.2 |
|
155.0 |
RPL09.WP4.022520 |
RPL09.Conn DHA.09.33<>33 Pull Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | Jumpers | Not Started | 10/04/27 | 10/06/27 | 3.8 | 3.8 |
|
146.2 |
RPL09.WP4.022540 |
RPL09.Conn DHA.10.37<>37 Pull Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | Jumpers | Not Started | 10/04/27 | 10/06/27 | 3.8 | 3.8 |
|
146.2 |
RPL09.WP4.022560 |
RPL09.Conn DHA.09 Install Ext. Trunk (24F) [PON (Passive, In-Rack)] | In-Rack | Not Started | 10/04/27 | 10/06/27 | 3.8 | 3.8 |
|
165.0 |
RPL09.WP4.022580 |
RPL09.Conn DHA.10 Install Ext. Trunk (24F) [PON (Passive, In-Rack)] | In-Rack | Not Started | 10/04/27 | 10/06/27 | 3.8 | 3.8 |
|
165.0 |
RPL09.WP4.024160 |
RPL09.Conn DHB.11.01<>01 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | In-Row | Not Started | 10/04/27 | 10/04/27 | 1.2 | 1.2 |
|
155.0 |
RPL09.WP4.024180 |
RPL09.Conn DHB.12.05<>05 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | In-Row | Not Started | 10/04/27 | 10/04/27 | 1.2 | 1.2 |
|
155.0 |
RPL09.WP4.024400 |
RPL09.Conn DHB.11 Install (Z-End) Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 10/04/27 | 10/05/27 | 2.5 | 2.5 |
|
150.0 |
RPL09.WP4.024420 |
RPL09.Conn DHB.12 Install (Z-End) Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 10/04/27 | 10/05/27 | 2.5 | 2.5 |
|
150.0 |
RPL09.WP4.024480 |
RPL09.Conn DHD.31 Pull Ext. Trunk (384F) [SSW<>JXSW] | SSW<>JXSW | Not Started | 10/04/27 | 10/04/27 | 1.2 | 1.2 |
|
241.2 |
RPL09.WP4.024500 |
RPL09.Conn DHD.32 Pull Ext. Trunk (384F) [SSW<>JXSW] | SSW<>JXSW | Not Started | 10/04/27 | 10/04/27 | 1.2 | 1.2 |
|
241.2 |
RPL09.WP4.024640 |
RPL09.Conn DHD.31.09 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 10/04/27 | 10/15/27 | 12.5 | 12.5 |
|
202.5 |
RPL09.WP4.024660 |
RPL09.Conn DHD.32.13 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 10/04/27 | 10/15/27 | 12.5 | 12.5 |
|
202.5 |
RPL09.WP4.025880 |
RPL09.Conn DHD.31 Pull Ext. Trunk (24F) [PON (Passive, In-Rack)] | In-Rack | Not Started | 10/04/27 | 10/04/27 | 1.2 | 1.2 |
|
233.8 |
RPL09.WP4.026120 |
RPL09.Conn DHD.32 Pull Ext. Trunk (24F) [PON (Passive, In-Rack)] | In-Rack | Not Started | 10/04/27 | 10/04/27 | 1.2 | 1.2 |
|
233.8 |
RPL09.WP4.047360 |
RPL09.Conn BE ISP DHA.CFD1 (RSL) FTSW > STSW EX384f [In-Row] | In-Row | Not Started | 10/04/27 | 10/06/27 | 3.8 | 3.8 |
|
222.5 |
RPL09.WP4.047600 |
RPL09.Conn BE ISP DHA.CFD2 (RSL) FTSW > STSW - TR288f (DHB NC>DHB Passive Racks) | CFD2 (Control Fault Domain A.2; Rows 09-16) | Not Started | 10/04/27 | 10/06/27 | 3.8 | 3.8 |
|
218.8 |
RPL09.CON.WP3.01840 |
RPL09.Conn EF1 Install OSP Pathway (for RPL09) - P4 | Infrastructure | Not Started | 10/05/27 | 10/08/27 | 5.0 | 5.0 |
|
317.5 |
RPL09.CON.WP3B.02740 |
RPL09.Conn EF2<>DHD.32 - WBS Summary | EF2<>DHD.32 | Not Started | 10/05/27 | 10/18/27 | 12.5 | 12.5 |
|
228.8 |
RPL09.Conn.FIM.00020 |
RPL09.Conn FIM - DHB - Prod EFs | Prod EFs | Not Started | 10/05/27 | 10/18/27 | 12.5 | 12.5 |
|
143.8 |
RPL09.OFCI.C.4540 |
OFCI Delivery: BE Fiber for CFD A.4 (ROJ ) (RVCD ) | Data Hall A | Not Started | 10/05/27 | 10/11/27 | 6.2 | 6.2 |
|
218.8 |
RPL09.WP3B.012440 |
RPL09.Conn EF2<>DHD.32 Pull Pigtails (384F) P2&3 (LV) | EF2<>DHD.32 | Not Started | 10/05/27 | 10/05/27 | 1.2 | 1.2 |
|
218.8 |
RPL09.WP3B.013860 |
RPL09.Conn EF2<>DHD.31 Install (A-End) Pigtails (384F) P2&3 (LV) | EF2<>DHD.31 | Not Started | 10/05/27 | 10/05/27 | 1.2 | 1.2 |
|
230.0 |
RPL09.WP3B.014720 |
RPL09.Conn EF2<>DHA.02 Splice (A-End) Pigtails (384F) P2&3 (MES) | EF2<>DHA.02 | Not Started | 10/05/27 | 10/12/27 | 7.5 | 7.5 |
|
145.0 |
RPL09.WP3B.016160 |
RPL09.Conn EF2<>DHA.02 Install (Z-End) Pigtails (384F) P2&3 (MES) | EF2<>DHA.02 | Not Started | 10/05/27 | 10/05/27 | 1.2 | 1.2 |
|
145.0 |
RPL09.WP3B.017240 |
RPL09.Conn EF1<>DHB.20 Test Pigtails (384F) P1&4 (MES) | EF1<>DHB.20 | Not Started | 10/05/27 | 10/06/27 | 2.5 | 2.5 |
|
141.2 |
RPL09.WP4.017000 |
RPL09.Conn DHB.18 Install (A-End) Ext. Trunk (384F) [SSW<>JXSW] | SSW<>JXSW | Not Started | 10/05/27 | 10/06/27 | 2.5 | 2.5 |
|
143.8 |
RPL09.WP4.017240 |
RPL09.Conn DHB.18 Install (A-End) Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 10/05/27 | 10/06/27 | 2.5 | 2.5 |
|
146.2 |
RPL09.WP4.017500 |
RPL09.Conn DHB.18 Install (A-End) Trunk (384F) [RSW<>FSW] | Trunks | Not Started | 10/05/27 | 10/08/27 | 5.0 | 5.0 |
|
146.2 |
RPL09.WP4.018760 |
RPL09.Conn DHB.18.29 Install (A-End) Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 10/05/27 | 10/06/27 | 2.5 | 2.5 |
|
153.8 |
RPL09.WP4.020920 |
RPL09.Conn DHB.18.30 Install (A-End) Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 10/05/27 | 10/06/27 | 2.5 | 2.5 |
|
153.8 |
RPL09.WP4.021840 |
RPL09.Conn DHA.09 Pull Trunk (384F) [RSW<>FSW] | Trunks | Not Started | 10/05/27 | 10/06/27 | 2.5 | 2.5 |
|
155.0 |
RPL09.WP4.021860 |
RPL09.Conn DHA.10 Pull Trunk (384F) [RSW<>FSW] | Trunks | Not Started | 10/05/27 | 10/06/27 | 2.5 | 2.5 |
|
155.0 |
RPL09.WP4.022760 |
RPL09.Conn DHB.18.31 Install (A-End) Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 10/05/27 | 10/06/27 | 2.5 | 2.5 |
|
153.8 |
RPL09.WP4.024520 |
RPL09.Conn DHB.11.03<>03 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | In-Row | Not Started | 10/05/27 | 10/05/27 | 1.2 | 1.2 |
|
155.0 |
RPL09.WP4.024540 |
RPL09.Conn DHB.12.07<>07 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | In-Row | Not Started | 10/05/27 | 10/05/27 | 1.2 | 1.2 |
|
155.0 |
RPL09.WP4.024680 |
RPL09.Conn DHD.31 Pull Trunk (192F) [FSW<>SSW] | Trunks | Not Started | 10/05/27 | 10/05/27 | 1.2 | 1.2 |
|
241.2 |
RPL09.WP4.024700 |
RPL09.Conn DHD.32 Pull Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 10/05/27 | 10/05/27 | 1.2 | 1.2 |
|
241.2 |
RPL09.WP4.026540 |
RPL09.Conn DHD.31.09<>09 Pull Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | Jumpers | Not Started | 10/05/27 | 10/07/27 | 3.8 | 3.8 |
|
233.8 |
RPL09.WP4.026560 |
RPL09.Conn DHD.31 Install Ext. Trunk (24F) [PON (Passive, In-Rack)] | In-Rack | Not Started | 10/05/27 | 10/07/27 | 3.8 | 3.8 |
|
250.0 |
RPL09.WP4.026880 |
RPL09.Conn DHD.32.13<>13 Pull Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | Jumpers | Not Started | 10/05/27 | 10/07/27 | 3.8 | 3.8 |
|
233.8 |
RPL09.WP4.026900 |
RPL09.Conn DHD.32 Install Ext. Trunk (24F) [PON (Passive, In-Rack)] | In-Rack | Not Started | 10/05/27 | 10/07/27 | 3.8 | 3.8 |
|
250.0 |
RPL09.WP4.046860 |
RPL09.Conn BE ISP DHB.NC2 (RSL) FTSW>STSW TYP NC-EX288F (In Row Active>Passive Rack) | Network Core 2 | Not Started | 10/05/27 | 10/07/27 | 3.8 | 3.8 |
|
285.0 |
DCC.B9.3045 |
[SSDCB4] Production Gear Delivered [DHC] Front End (SSW &FSW) | Connectivity | Not Started | 10/06/27 | 10/06/27 | 0.0 | 0.0 |
|
227.5 |
RPL09.CON.WP2.08920 |
RPL09.Conn - GSIDF/DH D1 - WBS Summary | INT IDF Stick Build - GSIDF9D1 | Not Started | 10/06/27 | 10/28/27 | 21.2 | 21.2 |
|
300.0 |
RPL09.CON.WP2.08940 |
RPL09.Conn - GSIDF/DH D1 - Install Infrastructure (Racks, Waterfalls etc.) | Infrastructure | Not Started | 10/06/27 | 10/12/27 | 6.2 | 6.2 |
|
242.5 |
RPL09.CON.WP3B.01960 |
RPL09.Conn EF2<>DHA.04 - WBS Summary | EF2<>DHA.04 | Not Started | 10/06/27 | 10/20/27 | 13.8 | 13.8 |
|
140.0 |
RPL09.CON.WP3B.02780 |
RPL09.Conn EF1<>DHD.32 - WBS Summary | EF1<>DHD.32 | Not Started | 10/06/27 | 10/20/27 | 13.8 | 13.8 |
|
226.2 |
RPL09.CON.WP3B.04120 |
RPL09.Conn WP#3B - ISP DHC - WBS Summary | DHC | Not Started | 10/06/27 | 12/20/27 | 63.8 | 63.8 |
|
176.2 |
RPL09.CON.WP4.08000 |
RPL09.Conn - DH C Network - WBS Summary | DH C | Not Started | 10/06/27 | 02/17/28 | 112.5 | 112.5 |
|
140.0 |
RPL09.CON.WP4.08020 |
RPL09.Conn WP4 FENW DHC CFD1 Infrastructure | Infrastructure | Not Started | 10/06/27 | 11/02/27 | 25.0 | 25.0 |
|
227.5 |
RPL09.CON.WP4.09940 |
RPL09.Conn A CFD2 - Deliver & Install - ORV3N (Loading at Night) | OFE- Passive In-row Racks, Racks (ORv3Ns, MCRs) & PON | Not Started | 10/06/27 | 10/15/27 | 10.0 | 10.0 |
|
116.2 |
RPL09.CON.WP4.09960 |
RPL09.Conn A CFD2 - Deliver & Assemble - PON | OFE- Passive In-row Racks, Racks (ORv3Ns, MCRs) & PON | Not Started | 10/06/27 | 10/15/27 | 10.0 | 10.0 |
|
151.2 |
RPL09.INT.CTRC.01650 |
RPL09.Interior.Center-Corridor (N) - Final Paint and Tube Steel Paint (IFP Add) | Fit out (North) | Not Started | 10/06/27 | 10/19/27 | 12.5 | 12.5 |
|
90.0 |
RPL09.INT.DHC.01200 |
RPL09.Conn DHC - CFD1 - Set Passive Racks for WP#3b (16) | Infrastructure | Not Started | 10/06/27 | 10/08/27 | 3.8 | 3.8 |
|
196.2 |
RPL09.INT.DHC.01380 |
RPL09.Interior.DHC - Control Fault Domain 2 - Install copper from GS.IDF to BMS and EPMS panels | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/06/27 | 11/02/27 | 25.0 | 25.0 |
|
161.2 |
RPL09.INT.DHC.01450 |
RPL09.Interior.DHC - Control Fault Domain 3 - Pull BMS from panel to devices | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/06/27 | 11/02/27 | 25.0 | 25.0 |
|
181.2 |
RPL09.INT.DHC.01460 |
RPL09.Interior.DHC - Control Fault Domain 3 - Pull EMPS from panel to devices | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/06/27 | 11/02/27 | 25.0 | 25.0 |
|
181.2 |
RPL09.INT.DHC.01470 |
RPL09.Interior.DHC - Control Fault Domain 3 - Set UPS and Panel (2) and GS.IDF C1 (Stick Build) | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/06/27 | 11/02/27 | 25.0 | 25.0 |
|
165.0 |
RPL09.INT.DHC.02590 |
RPL09.Conn DHC - CFD1 - Set Passive Racks for PON (16) | Infrastructure | Not Started | 10/06/27 | 10/08/27 | 3.8 | 3.8 |
|
217.5 |
RPL09.INT.DHD.01680 |
RPL09.Interior.DHD - Control Fault Domain 4 - L2 Checklist Completion | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/06/27 | 11/02/27 | 25.0 | 25.0 |
|
200.0 |
RPL09.SKN.E.LO.02100 |
RPL09.SKIN.LO#18 - Install IMP Flashing & Caulking | Build back Exterior Leave Out Walls #18 (EC - North) | Not Started | 10/06/27 | 10/07/27 | 2.5 | 2.5 |
|
138.8 |
RPL09.WP3B.011720 |
RPL09.Conn EF1<>DHD.32 Pull Pigtails (384F) P1&4 (MES) | EF1<>DHD.32 | Not Started | 10/06/27 | 10/07/27 | 2.5 | 2.5 |
|
216.2 |
RPL09.WP3B.011880 |
RPL09.Conn EF2<>DHA.04 Pull Pigtails (384F) P2&3 (MES) | EF2<>DHA.04 | Not Started | 10/06/27 | 10/07/27 | 2.5 | 2.5 |
|
131.2 |
RPL09.WP3B.013140 |
RPL09.Conn EF1<>DHD.31 Install (A-End) Pigtails (384F) P1&4 (MES) | EF1<>DHD.31 | Not Started | 10/06/27 | 10/06/27 | 1.2 | 1.2 |
|
228.8 |
RPL09.WP3B.013300 |
RPL09.Conn EF2<>DHA.03 Install (A-End) Pigtails (384F) P2&3 (MES) | EF2<>DHA.03 | Not Started | 10/06/27 | 10/06/27 | 1.2 | 1.2 |
|
142.5 |
RPL09.WP3B.013880 |
RPL09.Conn EF2<>DHD.32 Install (A-End) Pigtails (384F) P2&3 (LV) | EF2<>DHD.32 | Not Started | 10/06/27 | 10/06/27 | 1.2 | 1.2 |
|
228.8 |
RPL09.WP3B.015300 |
RPL09.Conn EF2<>DHD.31 Splice (A-End) Pigtails (384F) P2&3 (LV) | EF2<>DHD.31 | Not Started | 10/06/27 | 10/13/27 | 7.5 | 7.5 |
|
230.0 |
RPL09.WP3B.016740 |
RPL09.Conn EF2<>DHD.31 Install (Z-End) Pigtails (384F) P2&3 (LV) | EF2<>DHD.31 | Not Started | 10/06/27 | 10/06/27 | 1.2 | 1.2 |
|
230.0 |
RPL09.WP4.020040 |
RPL09.Conn DHB.19 Install (A-End) Ext. Trunk (384F) [SSW<>JXSW] | SSW<>JXSW | Not Started | 10/06/27 | 10/07/27 | 2.5 | 2.5 |
|
142.5 |
RPL09.WP4.020260 |
RPL09.Conn DHB.19 Install (A-End) Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 10/06/27 | 10/07/27 | 2.5 | 2.5 |
|
145.0 |
RPL09.WP4.020540 |
RPL09.Conn DHB.19 Install (A-End) Trunk (384F) [RSW<>FSW] | Trunks | Not Started | 10/06/27 | 10/11/27 | 5.0 | 5.0 |
|
145.0 |
RPL09.WP4.021680 |
RPL09.Conn DHB.19.33 Install (A-End) Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 10/06/27 | 10/07/27 | 2.5 | 2.5 |
|
152.5 |
RPL09.WP4.021800 |
RPL09.Conn DHA.07.28<>27 Install (A-End) Simplex Jumper (SC<>LC) [PON (Active, Across-Row)] | Across-Row | Not Started | 10/06/27 | 10/06/27 | 1.2 | 1.2 |
|
161.2 |
RPL09.WP4.022100 |
RPL09.Conn DHA.08.32<>31 Install (A-End) Simplex Jumper (SC<>LC) [PON (Active, Across-Row)] | Across-Row | Not Started | 10/06/27 | 10/06/27 | 1.2 | 1.2 |
|
161.2 |
RPL09.WP4.023960 |
RPL09.Conn DHB.19.34 Install (A-End) Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 10/06/27 | 10/07/27 | 2.5 | 2.5 |
|
152.5 |
RPL09.WP4.024920 |
RPL09.Conn DHB.11 Install (Z-End) Trunk (384F) [RSW<>FSW] | Trunks | Not Started | 10/06/27 | 10/11/27 | 5.0 | 5.0 |
|
150.0 |
RPL09.WP4.024940 |
RPL09.Conn DHB.12 Install (Z-End) Trunk (384F) [RSW<>FSW] | Trunks | Not Started | 10/06/27 | 10/11/27 | 5.0 | 5.0 |
|
150.0 |
RPL09.WP4.024960 |
RPL09.Conn DHD.31 Pull Trunk (384F) [RSW<>FSW] | RSW<>FSW | Not Started | 10/06/27 | 10/06/27 | 1.2 | 1.2 |
|
241.2 |
RPL09.WP4.024980 |
RPL09.Conn DHD.32 Pull Trunk (384F) [RSW<>FSW] | Trunks | Not Started | 10/06/27 | 10/06/27 | 1.2 | 1.2 |
|
241.2 |
GCD.RPL09.4665 |
L3/L4 Start - DHA Rows 17-24 | DH | Not Started | 10/07/27 | 10/07/27 | 0.0 | 0.0 |
|
148.8 |
RPL09.CX.DHA.01120 |
RPL09.CX.DHA - L3/L4 - Elec. Domain 05/06 | DHA ELECTRICAL | Not Started | 10/07/27 | 10/12/27 | 5.0 | 5.0 |
|
77.5 |
RPL09.INT.EC.9000 |
RPL09.Interior.ECr LO #14 - Hard Lid Framing | Remaining of LO Wall #14 (Ancillary, Elec Room, Humidifier Room & IDF) | Not Started | 10/07/27 | 10/11/27 | 3.8 | 3.8 |
|
170.0 |
RPL09.INT.EC.LO.8980 |
RPL09.Interior.EC LO #14 - Install Security Lowside OH | Interior Leave Out Wall #14 DHD/EC for DHB&D HACs | Not Started | 10/07/27 | 10/11/27 | 3.8 | 3.8 |
|
156.2 |
RPL09.INT.EC.LO.9000 |
RPL09.Interior.EC LO #14 - Install Controls / EPMS / BMS OH | Interior Leave Out Wall #14 DHD/EC for DHB&D HACs | Not Started | 10/07/27 | 10/11/27 | 3.8 | 3.8 |
|
151.2 |
RPL09.WP3B.014580 |
RPL09.Conn EF1<>DHD.31 Splice (A-End) Pigtails (384F) P1&4 (MES) | EF1<>DHD.31 | Not Started | 10/07/27 | 10/14/27 | 7.5 | 7.5 |
|
228.8 |
RPL09.WP3B.014740 |
RPL09.Conn EF2<>DHA.03 Splice (A-End) Pigtails (384F) P2&3 (MES) | EF2<>DHA.03 | Not Started | 10/07/27 | 10/14/27 | 7.5 | 7.5 |
|
142.5 |
RPL09.WP3B.015320 |
RPL09.Conn EF2<>DHD.32 Splice (A-End) Pigtails (384F) P2&3 (LV) | EF2<>DHD.32 | Not Started | 10/07/27 | 10/14/27 | 7.5 | 7.5 |
|
228.8 |
RPL09.WP3B.016020 |
RPL09.Conn EF1<>DHD.31 Install (Z-End) Pigtails (384F) P1&4 (MES) | EF1<>DHD.31 | Not Started | 10/07/27 | 10/07/27 | 1.2 | 1.2 |
|
228.8 |
RPL09.WP3B.016180 |
RPL09.Conn EF2<>DHA.03 Install (Z-End) Pigtails (384F) P2&3 (MES) | EF2<>DHA.03 | Not Started | 10/07/27 | 10/07/27 | 1.2 | 1.2 |
|
142.5 |