Schedule Viewer
Last schedule upload: D3-R25005-00-RPL06 — 6139 activities — 04/16/2026 08:19 AM CT
RPL08 - GC LIVE SCHEDULE - Data Date 2026.04.12.xer
· Uploaded Apr 16, 2026 01:14 PM
· 5122 activities
Experimental
Auto-populate checklist dates from schedule:
100
Activities Shown
0
Completed
0
In Progress
0
Critical
| Activity ID | Activity Name | WBS | Status | Start | Finish | Dur (d) | Rem (d) | % Comp | Float (d) |
|---|---|---|---|---|---|---|---|---|---|
RPL08.WP4.017240 |
RPL08.Conn DHB.18 Install (A-End) Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 06/24/27 | 06/25/27 | 2.5 | 2.5 |
|
162.5 |
RPL08.WP4.017500 |
RPL08.Conn DHB.18 Install (A-End) Trunk (384F) [RSW<>FSW] | Trunks | Not Started | 06/24/27 | 06/29/27 | 5.0 | 5.0 |
|
162.5 |
RPL08.WP4.018440 |
RPL08.Conn DHA.01.04 Install (A-End) Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 06/24/27 | 06/25/27 | 2.5 | 2.5 |
|
182.5 |
RPL08.WP4.018760 |
RPL08.Conn DHB.18.29 Install (A-End) Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 06/24/27 | 06/25/27 | 2.5 | 2.5 |
|
170.0 |
RPL08.WP4.020920 |
RPL08.Conn DHB.18.30 Install (A-End) Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 06/24/27 | 06/25/27 | 2.5 | 2.5 |
|
170.0 |
RPL08.WP4.022060 |
RPL08.Conn DHA.05.20 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 06/24/27 | 07/08/27 | 12.5 | 12.5 |
|
170.0 |
RPL08.WP4.022080 |
RPL08.Conn DHA.06.24 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 06/24/27 | 07/08/27 | 12.5 | 12.5 |
|
170.0 |
RPL08.WP4.022600 |
RPL08.Conn DHA.07.27 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 06/24/27 | 07/08/27 | 12.5 | 12.5 |
|
157.5 |
RPL08.WP4.022620 |
RPL08.Conn DHA.08.31 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 06/24/27 | 07/08/27 | 12.5 | 12.5 |
|
157.5 |
RPL08.WP4.022760 |
RPL08.Conn DHB.18.31 Install (A-End) Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 06/24/27 | 06/25/27 | 2.5 | 2.5 |
|
170.0 |
RPL08.WP4.024680 |
RPL08.Conn DHD.31 Pull Trunk (192F) [FSW<>SSW] | Trunks | Not Started | 06/24/27 | 06/24/27 | 1.2 | 1.2 |
|
256.2 |
RPL08.WP4.024700 |
RPL08.Conn DHD.32 Pull Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 06/24/27 | 06/24/27 | 1.2 | 1.2 |
|
256.2 |
RPL08.WP4.025840 |
RPL08.Conn DHC.21 Pull Trunk (384F) [RSW<>FSW] | Trunks | Not Started | 06/24/27 | 06/24/27 | 1.2 | 1.2 |
|
257.5 |
RPL08.WP4.025860 |
RPL08.Conn DHC.22 Pull Trunk (384F) [RSW<>FSW] | Trunks | Not Started | 06/24/27 | 06/24/27 | 1.2 | 1.2 |
|
257.5 |
RPL08.WP4.026540 |
RPL08.Conn DHD.31.09<>09 Pull Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | Jumpers | Not Started | 06/24/27 | 06/28/27 | 3.8 | 3.8 |
|
248.8 |
RPL08.WP4.026560 |
RPL08.Conn DHD.31 Install Ext. Trunk (24F) [PON (Passive, In-Rack)] | In-Rack | Not Started | 06/24/27 | 06/28/27 | 3.8 | 3.8 |
|
265.0 |
RPL08.WP4.026800 |
RPL08.Conn DHA.01.04<>03 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, Across-Row)] | Across-Row | Not Started | 06/24/27 | 06/24/27 | 1.2 | 1.2 |
|
181.2 |
RPL08.WP4.026820 |
RPL08.Conn DHA.02.08<>07 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, Across-Row)] | Across-Row | Not Started | 06/24/27 | 06/24/27 | 1.2 | 1.2 |
|
181.2 |
RPL08.WP4.026840 |
RPL08.Conn DHB.13.12<>11 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, Across-Row)] | Across-Row | Not Started | 06/24/27 | 06/24/27 | 1.2 | 1.2 |
|
168.8 |
RPL08.WP4.026860 |
RPL08.Conn DHB.14.16<>15 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, Across-Row)] | Across-Row | Not Started | 06/24/27 | 06/24/27 | 1.2 | 1.2 |
|
168.8 |
RPL08.WP4.026880 |
RPL08.Conn DHD.32.13<>13 Pull Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | Jumpers | Not Started | 06/24/27 | 06/28/27 | 3.8 | 3.8 |
|
248.8 |
RPL08.WP4.026900 |
RPL08.Conn DHD.32 Install Ext. Trunk (24F) [PON (Passive, In-Rack)] | In-Rack | Not Started | 06/24/27 | 06/28/27 | 3.8 | 3.8 |
|
265.0 |
RPL08.WP4.046860 |
RPL08.Conn BE ISP DHB.NC2 Install Trunks Extenders FTSW (RSL) to STSW 288f | Network Core 2 | Not Started | 06/24/27 | 06/28/27 | 3.8 | 3.8 |
|
300.0 |
RPL08.WP4.047380 |
RPL08.Conn BE ISP DHA.CFD1 Pull/Dress/Test FTSW (RSL) to STSW EX384f [Across-Row] | Across-Row | Not Started | 06/24/27 | 06/28/27 | 3.8 | 3.8 |
|
240.0 |
RPL08.WP4.047620 |
RPL08.Conn BE ISP DHA.CFD2 Pull/Dress/Test FTSW (RSL) to STSW EX384f Typical Row Pair [In-Row] | In-Row | Not Started | 06/24/27 | 06/28/27 | 3.8 | 3.8 |
|
240.0 |
RPL08.WP4.047720 |
RPL08.Conn BE ISP DHA.CFD4 Install Trunks FTSW (RSL) to STSW | CFD4 (Control Fault Domain A.4; Rows 25-32) | Not Started | 06/24/27 | 06/28/27 | 3.8 | 3.8 |
|
240.0 |
RPL08.CON.WP2.08920 |
RPL08.Conn - GSIDF/DH D1 - WBS Summary | Int. IDF Stick Built - GSIDF8D1 | Not Started | 06/25/27 | 07/20/27 | 21.2 | 21.2 |
|
315.0 |
RPL08.CON.WP2.08940 |
RPL08.Conn - GSIDF/DH D1 - Install Infrastructure (Racks, Waterfalls etc.) | Infrastructure | Not Started | 06/25/27 | 07/01/27 | 6.2 | 6.2 |
|
256.2 |
RPL08.CON.WP3B.02100 |
RPL08.Conn EF2<>DHA.08 - WBS Summary | EF2<>DHA.08 | Not Started | 06/25/27 | 07/09/27 | 12.5 | 12.5 |
|
158.8 |
RPL08.CON.WP3B.02780 |
RPL08.Conn EF1<>DHD.32 - WBS Summary | EF1<>DHD.32 | Not Started | 06/25/27 | 07/12/27 | 13.8 | 13.8 |
|
241.2 |
RPL08.Conn.FIM.01360 |
RPL08.Conn FIM - DHA - Control Fault Domain A.2 | DHA | Not Started | 06/25/27 | 07/23/27 | 25.0 | 25.0 |
|
165.0 |
RPL08.INT.DHD.01680 |
RPL08.Interior.DHD - Control Fault Domain 4 - L2 Checklist Completion | Remaining Tie-ins post Mech Side Aisle install | Not Started | 06/25/27 | 07/23/27 | 25.0 | 25.0 |
|
213.8 |
RPL08.SKN.E.LO.02100 |
RPL08.SKIN.LO#18 - Install IMP Flashing & Caulking | Build back Exterior Leave Out Walls #18 (EC - North) | Not Started | 06/25/27 | 06/28/27 | 2.5 | 2.5 |
|
152.5 |
RPL08.WP3B.011720 |
RPL08.Conn EF1<>DHD.32 Pull Pigtails (384F) P1&4 (MES) | EF1<>DHD.32 | Not Started | 06/25/27 | 06/28/27 | 2.5 | 2.5 |
|
231.2 |
RPL08.WP3B.011960 |
RPL08.Conn EF2<>DHA.08 Pull Pigtails (384F) P2&3 (MES) | EF2<>DHA.08 | Not Started | 06/25/27 | 06/25/27 | 1.2 | 1.2 |
|
156.2 |
RPL08.WP3B.013140 |
RPL08.Conn EF1<>DHD.31 Install (A-End) Pigtails (384F) P1&4 (MES) | EF1<>DHD.31 | Not Started | 06/25/27 | 06/25/27 | 1.2 | 1.2 |
|
243.8 |
RPL08.WP3B.013380 |
RPL08.Conn EF2<>DHA.07 Install (A-End) Pigtails (384F) P2&3 (MES) | EF2<>DHA.07 | Not Started | 06/25/27 | 06/25/27 | 1.2 | 1.2 |
|
160.0 |
RPL08.WP3B.013880 |
RPL08.Conn EF2<>DHD.32 Install (A-End) Pigtails (384F) P2&3 (LV) | EF2<>DHD.32 | Not Started | 06/25/27 | 06/25/27 | 1.2 | 1.2 |
|
243.8 |
RPL08.WP3B.014400 |
RPL08.Conn EF1<>DHC.22 Splice (A-End) Pigtails (384F) P1&4 (LV) | EF1<>DHC.22 | Not Started | 06/25/27 | 07/02/27 | 7.5 | 7.5 |
|
245.0 |
RPL08.WP3B.014800 |
RPL08.Conn EF2<>DHA.06 Splice (A-End) Pigtails (384F) P2&3 (MES) | EF2<>DHA.06 | Not Started | 06/25/27 | 07/02/27 | 7.5 | 7.5 |
|
161.2 |
RPL08.WP3B.015120 |
RPL08.Conn EF2<>DHC.22 Splice (A-End) Pigtails (384F) P2&3 (MES) | EF2<>DHC.22 | Not Started | 06/25/27 | 07/02/27 | 7.5 | 7.5 |
|
245.0 |
RPL08.WP3B.015300 |
RPL08.Conn EF2<>DHD.31 Splice (A-End) Pigtails (384F) P2&3 (LV) | EF2<>DHD.31 | Not Started | 06/25/27 | 07/02/27 | 7.5 | 7.5 |
|
245.0 |
RPL08.WP3B.015840 |
RPL08.Conn EF1<>DHC.22 Install (Z-End) Pigtails (384F) P1&4 (LV) | EF1<>DHC.22 | Not Started | 06/25/27 | 06/25/27 | 1.2 | 1.2 |
|
245.0 |
RPL08.WP3B.016240 |
RPL08.Conn EF2<>DHA.06 Install (Z-End) Pigtails (384F) P2&3 (MES) | EF2<>DHA.06 | Not Started | 06/25/27 | 06/25/27 | 1.2 | 1.2 |
|
161.2 |
RPL08.WP3B.016560 |
RPL08.Conn EF2<>DHC.22 Install (Z-End) Pigtails (384F) P2&3 (MES) | EF2<>DHC.22 | Not Started | 06/25/27 | 06/25/27 | 1.2 | 1.2 |
|
245.0 |
RPL08.WP3B.016740 |
RPL08.Conn EF2<>DHD.31 Install (Z-End) Pigtails (384F) P2&3 (LV) | EF2<>DHD.31 | Not Started | 06/25/27 | 06/25/27 | 1.2 | 1.2 |
|
245.0 |
RPL08.WP4.020040 |
RPL08.Conn DHB.19 Install (A-End) Ext. Trunk (384F) [SSW<>JXSW] | SSW<>JXSW | Not Started | 06/25/27 | 06/28/27 | 2.5 | 2.5 |
|
158.8 |
RPL08.WP4.020260 |
RPL08.Conn DHB.19 Install (A-End) Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 06/25/27 | 06/28/27 | 2.5 | 2.5 |
|
161.2 |
RPL08.WP4.020540 |
RPL08.Conn DHB.19 Install (A-End) Trunk (384F) [RSW<>FSW] | Trunks | Not Started | 06/25/27 | 06/30/27 | 5.0 | 5.0 |
|
161.2 |
RPL08.WP4.021680 |
RPL08.Conn DHB.19.33 Install (A-End) Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 06/25/27 | 06/28/27 | 2.5 | 2.5 |
|
168.8 |
RPL08.WP4.023960 |
RPL08.Conn DHB.19.34 Install (A-End) Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 06/25/27 | 06/28/27 | 2.5 | 2.5 |
|
168.8 |
RPL08.WP4.024960 |
RPL08.Conn DHD.31 Pull Trunk (384F) [RSW<>FSW] | RSW<>FSW | Not Started | 06/25/27 | 06/25/27 | 1.2 | 1.2 |
|
256.2 |
RPL08.WP4.024980 |
RPL08.Conn DHD.32 Pull Trunk (384F) [RSW<>FSW] | Trunks | Not Started | 06/25/27 | 06/25/27 | 1.2 | 1.2 |
|
256.2 |
RPL08.WP4.027000 |
RPL08.Conn DHA.01.01<>01 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | In-Row | Not Started | 06/25/27 | 06/25/27 | 1.2 | 1.2 |
|
181.2 |
RPL08.WP4.027020 |
RPL08.Conn DHA.02.05<>05 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | In-Row | Not Started | 06/25/27 | 06/25/27 | 1.2 | 1.2 |
|
181.2 |
RPL08.WP4.027040 |
RPL08.Conn DHB.13.09<>09 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | In-Row | Not Started | 06/25/27 | 06/25/27 | 1.2 | 1.2 |
|
168.8 |
RPL08.WP4.027060 |
RPL08.Conn DHB.14.13<>13 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | In-Row | Not Started | 06/25/27 | 06/25/27 | 1.2 | 1.2 |
|
168.8 |
RPL08.WP4.027320 |
RPL08.Conn DHB.13 Install (Z-End) Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 06/25/27 | 06/28/27 | 2.5 | 2.5 |
|
163.8 |
RPL08.WP4.027340 |
RPL08.Conn DHB.14 Install (Z-End) Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 06/25/27 | 06/28/27 | 2.5 | 2.5 |
|
163.8 |
GCD.RPL08.4165 |
[RPL08] TC-C Ready : Production Cabling Start [DHA Rows 33-40] | TC-C Ready: Production Cabling - DHA | Not Started | 06/28/27 | 06/28/27 | 0.0 | 0.0 |
|
335.0 |
RPL08.CON.WP3B.02200 |
RPL08.Conn EF2<>DHA.09 - WBS Summary | EF2<>DHA.09 | Not Started | 06/28/27 | 07/12/27 | 12.5 | 12.5 |
|
157.5 |
RPL08.CON.WP3B.02240 |
RPL08.Conn EF1<>DHA.09 - WBS Summary | MPOD09 | Not Started | 06/28/27 | 07/12/27 | 12.5 | 12.5 |
|
157.5 |
RPL08.INT.EC.9000 |
RPL08.Interior.ECr LO #14 - Hard Lid Framing | Remaining of LO Wall #14 (Ancillary, Elec Room, Humidifier Room & IDF) | Not Started | 06/28/27 | 06/30/27 | 3.8 | 3.8 |
|
183.8 |
RPL08.INT.EC.LO.8980 |
RPL08.Interior.EC LO #14 - Install Security Lowside OH | Interior Leave Out Wall #14 DHD/EC for DHB&D HACs | Not Started | 06/28/27 | 06/30/27 | 3.8 | 3.8 |
|
170.0 |
RPL08.INT.EC.LO.9000 |
RPL08.Interior.EC LO #14 - Install Controls / EPMS / BMS OH | Interior Leave Out Wall #14 DHD/EC for DHB&D HACs | Not Started | 06/28/27 | 06/30/27 | 3.8 | 3.8 |
|
165.0 |
RPL08.SKN.E.LO.04040 |
RPL08.SKIN.LO#19 - Cure Stemwall | Build back Exterior Leave Out Walls #19 (EC - South) | Not Started | 06/28/27 | 07/07/27 | 8.8 | 8.8 |
|
142.5 |
RPL08.WP3B.011980 |
RPL08.Conn EF2<>DHA.09 Pull Pigtails (384F) P2&3 (MES) | EF2<>DHA.09 | Not Started | 06/28/27 | 06/28/27 | 1.2 | 1.2 |
|
156.2 |
RPL08.WP3B.013400 |
RPL08.Conn EF2<>DHA.08 Install (A-End) Pigtails (384F) P2&3 (MES) | EF2<>DHA.08 | Not Started | 06/28/27 | 06/28/27 | 1.2 | 1.2 |
|
158.8 |
RPL08.WP3B.014580 |
RPL08.Conn EF1<>DHD.31 Splice (A-End) Pigtails (384F) P1&4 (MES) | EF1<>DHD.31 | Not Started | 06/28/27 | 07/06/27 | 7.5 | 7.5 |
|
243.8 |
RPL08.WP3B.014820 |
RPL08.Conn EF2<>DHA.07 Splice (A-End) Pigtails (384F) P2&3 (MES) | EF2<>DHA.07 | Not Started | 06/28/27 | 07/06/27 | 7.5 | 7.5 |
|
160.0 |
RPL08.WP3B.015320 |
RPL08.Conn EF2<>DHD.32 Splice (A-End) Pigtails (384F) P2&3 (LV) | EF2<>DHD.32 | Not Started | 06/28/27 | 07/06/27 | 7.5 | 7.5 |
|
243.8 |
RPL08.WP3B.016020 |
RPL08.Conn EF1<>DHD.31 Install (Z-End) Pigtails (384F) P1&4 (MES) | EF1<>DHD.31 | Not Started | 06/28/27 | 06/28/27 | 1.2 | 1.2 |
|
243.8 |
RPL08.WP3B.016260 |
RPL08.Conn EF2<>DHA.07 Install (Z-End) Pigtails (384F) P2&3 (MES) | EF2<>DHA.07 | Not Started | 06/28/27 | 06/28/27 | 1.2 | 1.2 |
|
160.0 |
RPL08.WP3B.016760 |
RPL08.Conn EF2<>DHD.32 Install (Z-End) Pigtails (384F) P2&3 (LV) | EF2<>DHD.32 | Not Started | 06/28/27 | 06/28/27 | 1.2 | 1.2 |
|
243.8 |
RPL08.WP3B.017620 |
RPL08.Conn EF2<>DHA.03 Test Pigtails (384F) P2&3 (MES) | EF2<>DHA.03 | Not Started | 06/28/27 | 06/29/27 | 2.5 | 2.5 |
|
167.5 |
RPL08.WP4.011200 |
RPL08.Conn DHA.02 Install (A-End) Ext. Trunk (384F) [SSW<>JXSW] | SSW<>JXSW | Not Started | 06/28/27 | 06/29/27 | 2.5 | 2.5 |
|
170.0 |
RPL08.WP4.011420 |
RPL08.Conn DHA.02 Install (A-End) Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 06/28/27 | 06/29/27 | 2.5 | 2.5 |
|
172.5 |
RPL08.WP4.011960 |
RPL08.Conn DHA.02 Install (A-End) Trunk (384F) [RSW<>FSW] | Trunks | Not Started | 06/28/27 | 07/01/27 | 5.0 | 5.0 |
|
172.5 |
RPL08.WP4.012720 |
RPL08.Conn DHA.02.05 Install (A-End) Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 06/28/27 | 06/29/27 | 2.5 | 2.5 |
|
180.0 |
RPL08.WP4.014500 |
RPL08.Conn DHA.02.06 Install (A-End) Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 06/28/27 | 06/29/27 | 2.5 | 2.5 |
|
180.0 |
RPL08.WP4.016380 |
RPL08.Conn DHA.02.07 Install (A-End) Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 06/28/27 | 06/29/27 | 2.5 | 2.5 |
|
180.0 |
RPL08.WP4.018460 |
RPL08.Conn DHA.02.08 Install (A-End) Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 06/28/27 | 06/29/27 | 2.5 | 2.5 |
|
180.0 |
RPL08.WP4.020060 |
RPL08.Conn DHB.20 Install (A-End) Ext. Trunk (384F) [SSW<>JXSW] | SSW<>JXSW | Not Started | 06/28/27 | 06/29/27 | 2.5 | 2.5 |
|
157.5 |
RPL08.WP4.020280 |
RPL08.Conn DHB.20 Install (A-End) Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 06/28/27 | 06/29/27 | 2.5 | 2.5 |
|
160.0 |
RPL08.WP4.020560 |
RPL08.Conn DHB.20 Install (A-End) Trunk (384F) [RSW<>FSW] | Trunks | Not Started | 06/28/27 | 07/01/27 | 5.0 | 5.0 |
|
160.0 |
RPL08.WP4.021700 |
RPL08.Conn DHB.20.37 Install (A-End) Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 06/28/27 | 06/29/27 | 2.5 | 2.5 |
|
167.5 |
RPL08.WP4.023840 |
RPL08.Conn DHA.09.34 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 06/28/27 | 07/12/27 | 12.5 | 12.5 |
|
142.5 |
RPL08.WP4.023860 |
RPL08.Conn DHA.10.38 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 06/28/27 | 07/12/27 | 12.5 | 12.5 |
|
142.5 |
RPL08.WP4.023980 |
RPL08.Conn DHB.20.38 Install (A-End) Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 06/28/27 | 06/29/27 | 2.5 | 2.5 |
|
167.5 |
RPL08.WP4.026460 |
RPL08.Conn DHA.01 Install (Z-End) Ext. Trunk (384F) [SSW<>JXSW] | SSW<>JXSW | Not Started | 06/28/27 | 06/29/27 | 2.5 | 2.5 |
|
172.5 |
RPL08.WP4.027540 |
RPL08.Conn DHA.01.03<>03 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | In-Row | Not Started | 06/28/27 | 06/28/27 | 1.2 | 1.2 |
|
181.2 |
RPL08.WP4.027560 |
RPL08.Conn DHA.02.07<>07 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | In-Row | Not Started | 06/28/27 | 06/28/27 | 1.2 | 1.2 |
|
181.2 |
RPL08.WP4.027580 |
RPL08.Conn DHB.13.11<>11 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | In-Row | Not Started | 06/28/27 | 06/28/27 | 1.2 | 1.2 |
|
168.8 |
RPL08.WP4.027600 |
RPL08.Conn DHB.14.15<>15 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | In-Row | Not Started | 06/28/27 | 06/28/27 | 1.2 | 1.2 |
|
168.8 |
RPL08.WP4.028520 |
RPL08.Conn DHC.21.03<>03 Pull Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | Jumpers | Not Started | 06/28/27 | 06/30/27 | 3.8 | 3.8 |
|
250.0 |
RPL08.WP4.028540 |
RPL08.Conn DHC.22.07<>07 Pull Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | Jumpers | Not Started | 06/28/27 | 06/30/27 | 3.8 | 3.8 |
|
250.0 |
RPL08.CON.WP3B.02180 |
RPL08.Conn EF2<>DHA.10 - WBS Summary | EF2<>DHA.10 | Not Started | 06/29/27 | 07/13/27 | 12.5 | 12.5 |
|
156.2 |
RPL08.CON.WP3B.02220 |
RPL08.Conn EF1<>DHA.10 - WBS Summary | MPOD10 | Not Started | 06/29/27 | 07/13/27 | 12.5 | 12.5 |
|
156.2 |
RPL08.CON.WP4.010000 |
RPL08.Conn A CFD3 - Deliver & Assemble - PON | OFE- Passive In-row Racks, Racks (ORv3Ns, MCRs) & PON | Not Started | 06/29/27 | 07/09/27 | 10.0 | 10.0 |
|
166.2 |
RPL08.CON.WP4.09980 |
RPL08.Conn A CFD3 - Deliver & Install - ORV3N (Loading at Night) | OFE- Passive In-row Racks, Racks (ORv3Ns, MCRs) & PON | Not Started | 06/29/27 | 07/09/27 | 10.0 | 10.0 |
|
141.2 |