Schedule Viewer
Last schedule upload: D3-R25005-00-RPL06 — 6139 activities — 04/16/2026 08:19 AM CT
RPL07 - GC LIVE SCHEDULE - Data Date 2026.04.12.xer
· Uploaded Apr 16, 2026 01:16 PM
· 5237 activities
Experimental
Auto-populate checklist dates from schedule:
100
Activities Shown
0
Completed
0
In Progress
0
Critical
| Activity ID | Activity Name | WBS | Status | Start | Finish | Dur (d) | Rem (d) | % Comp | Float (d) |
|---|---|---|---|---|---|---|---|---|---|
RPL07.WP3B.017320 |
RPL07.Conn EF1<>DHC.24 Test Pigtails (384F) P1&4 (LV) | EF1<>DHC.24 | Not Started | 04/30/27 | 05/03/27 | 2.5 | 2.5 |
|
143.8 |
RPL07.WP3B.017460 |
RPL07.Conn EF1<>DHD.31 Test Pigtails (384F) P1&4 (MES) | EF1<>DHD.31 | Not Started | 04/30/27 | 05/03/27 | 2.5 | 2.5 |
|
131.2 |
RPL07.WP3B.018200 |
RPL07.Conn EF2<>DHD.32 Test Pigtails (384F) P2&3 (LV) | EF2<>DHD.32 | Not Started | 04/30/27 | 05/03/27 | 2.5 | 2.5 |
|
131.2 |
RPL07.WP4.033720 |
RPL07.Conn DHA.05.20<>19 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, Across-Row)] | Across-Row | Not Started | 04/30/27 | 04/30/27 | 1.2 | 1.2 |
|
63.8 |
RPL07.WP4.033740 |
RPL07.Conn DHA.06.24<>23 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, Across-Row)] | Across-Row | Not Started | 04/30/27 | 04/30/27 | 1.2 | 1.2 |
|
63.8 |
GCD.RPL07.4285 |
[RPL07] TC-C Ready : Production Cabling Start [DHD Rows 17-24] | TC-C Ready: Production Cabling - DHD | Not Started | 05/03/27 | 05/03/27 | 0.0 | 0.0 |
|
213.8 |
GCD.RPL07.4445 |
[RPL07] TC-C Ready : Production Cabling Start [DHC Rows 17-24] | TC-C Ready: Production Cabling - DHC | Not Started | 05/03/27 | 05/03/27 | 0.0 | 0.0 |
|
213.8 |
RPL07.CON.WP2.15060 |
RPL07.Conn - GSMDF1(South)<>DH D - CFD3 Rack #01 Pull, Install & Test PON Trunks | MDF1 <> DH D - Rack#01 MES side | Not Started | 05/03/27 | 05/06/27 | 5.0 | 5.0 |
|
128.8 |
RPL07.CON.WP2.16060 |
RPL07.Conn - GSMDF2(North)<>DH D - CFD3 Rack #50 Pull, Install & Patch PON Trunks | MDF2 <> DH D - Rack#50 LV side | Not Started | 05/03/27 | 05/07/27 | 6.2 | 6.2 |
|
126.2 |
RPL07.CON.WP2.17060 |
RPL07.Conn - GSMDF1(South)<>DH C - CFD3 Rack #50 Pull, Install & Patch PON Trunks | MDF1 <> DH C - Rack#50 LV side | Not Started | 05/03/27 | 05/07/27 | 6.2 | 6.2 |
|
126.2 |
RPL07.CON.WP3B.02840 |
RPL07.Conn EF2<>DHD.33 - WBS Summary | EF2<>DHD.33 | Not Started | 05/03/27 | 05/17/27 | 13.8 | 13.8 |
|
118.8 |
RPL07.CON.WP3B.02880 |
RPL07.Conn EF1<>DHD.33 - WBS Summary | EF1<>DHD.33 | Not Started | 05/03/27 | 05/17/27 | 13.8 | 13.8 |
|
118.8 |
RPL07.CON.WP3B.03540 |
RPL07.Conn EF2<>DHC.24 - WBS Summary | EF2<>DHC.24 | Not Started | 05/03/27 | 05/14/27 | 12.5 | 12.5 |
|
132.5 |
RPL07.CON.WP3B.03680 |
RPL07.Conn EF1<>DHC.25 - WBS Summary | EF1<>DHC.25 | Not Started | 05/03/27 | 05/14/27 | 12.5 | 12.5 |
|
120.0 |
RPL07.CX.DHA.01170 |
RPL07.CX.DHA - L3/L4 - Control Fault Domain 05 | Control Fault Domain 5 | Not Started | 05/03/27 | 05/24/27 | 20.0 | 20.0 |
|
23.8 |
RPL07.INT.EC.9040 |
RPL07.Interior.ECr LO #14 - Backing | Remaining of LO Wall #14 (Ancillary, Elec Room, Humidifier Room & IDF) | Not Started | 05/03/27 | 05/04/27 | 2.5 | 2.5 |
|
62.5 |
RPL07.INT.EC.9400 |
RPL07.Interior.EC LO #15 - Install Security Lowside OH & In Wall | Remaining of LO #15 (Ancillary, Elec Room, Humidifier Room & IDF) | Not Started | 05/03/27 | 05/05/27 | 3.8 | 3.8 |
|
55.0 |
RPL07.INT.EC.9420 |
RPL07.Interior.EC LO #15 - Install Controls / EPMS / BMS OH & In Wall | Remaining of LO #15 (Ancillary, Elec Room, Humidifier Room & IDF) | Not Started | 05/03/27 | 05/05/27 | 3.8 | 3.8 |
|
55.0 |
RPL07.INT.EC.9440 |
RPL07.Interior.EC LO #15 - Install Fire Life Safety Lowside OH & In Wall | Remaining of LO #15 (Ancillary, Elec Room, Humidifier Room & IDF) | Not Started | 05/03/27 | 05/05/27 | 3.8 | 3.8 |
|
55.0 |
RPL07.INT.EC.9460 |
RPL07.Interior.EC LO #15 - Install Plumbing Lowside OH & In Wall | Remaining of LO #15 (Ancillary, Elec Room, Humidifier Room & IDF) | Not Started | 05/03/27 | 05/05/27 | 3.8 | 3.8 |
|
55.0 |
RPL07.INT.EC.9480 |
RPL07.Interior.EC LO #15 - Install Mechanical Piping Lowside OH & In Wall | Remaining of LO #15 (Ancillary, Elec Room, Humidifier Room & IDF) | Not Started | 05/03/27 | 05/05/27 | 3.8 | 3.8 |
|
55.0 |
RPL07.INT.EC.9500 |
RPL07.Interior.EC LO #15 - Install Electrical Lowside OH & In Wall | Remaining of LO #15 (Ancillary, Elec Room, Humidifier Room & IDF) | Not Started | 05/03/27 | 05/05/27 | 3.8 | 3.8 |
|
55.0 |
RPL07.INT.EC.LO.9040 |
RPL07.Interior.EC LO #14 - Install Door Frames | Interior Leave Out Wall #14 DHD/EC for DHB&D HACs | Not Started | 05/03/27 | 05/04/27 | 2.5 | 2.5 |
|
43.8 |
RPL07.INT.EC.LO.9360 |
RPL07.Interior.EC LO #15 - Install Fire Life Safety Lowside OH | Interior Leave Out Wall #15 DHC/EC for DHA&C HACs | Not Started | 05/03/27 | 05/05/27 | 3.8 | 3.8 |
|
51.2 |
RPL07.INT.EC.LO.9380 |
RPL07.Interior.EC LO #15 - Install Plumbing Lowside OH | Interior Leave Out Wall #15 DHC/EC for DHA&C HACs | Not Started | 05/03/27 | 05/05/27 | 3.8 | 3.8 |
|
46.2 |
RPL07.SKN.E.LO.04100 |
RPL07.SKIN.LO#19 - Install IMP Insulated Metal Panels | Build back Exterior Leave Out Walls #19 (EC - South) | Not Started | 05/03/27 | 05/04/27 | 2.5 | 2.5 |
|
53.8 |
RPL07.WP3B.011580 |
RPL07.Conn EF1<>DHC.25 Pull Pigtails (384F) P1&4 (LV) | EF1<>DHC.25 | Not Started | 05/03/27 | 05/03/27 | 1.2 | 1.2 |
|
115.0 |
RPL07.WP3B.011740 |
RPL07.Conn EF1<>DHD.33 Pull Pigtails (384F) P1&4 (MES) | EF1<>DHD.33 | Not Started | 05/03/27 | 05/04/27 | 2.5 | 2.5 |
|
111.2 |
RPL07.WP3B.012280 |
RPL07.Conn EF2<>DHC.24 Pull Pigtails (384F) P2&3 (MES) | EF2<>DHC.24 | Not Started | 05/03/27 | 05/03/27 | 1.2 | 1.2 |
|
110.0 |
RPL07.WP3B.012460 |
RPL07.Conn EF2<>DHD.33 Pull Pigtails (384F) P2&3 (LV) | EF2<>DHD.33 | Not Started | 05/03/27 | 05/04/27 | 2.5 | 2.5 |
|
111.2 |
RPL07.WP3B.013700 |
RPL07.Conn EF2<>DHC.23 Install (A-End) Pigtails (384F) P2&3 (MES) | EF2<>DHC.23 | Not Started | 05/03/27 | 05/03/27 | 1.2 | 1.2 |
|
121.2 |
RPL07.WP4.028320 |
RPL07.Conn DHD.33 Pull Ext. Trunk (384F) [SSW<>JXSW] | SSW<>JXSW | Not Started | 05/03/27 | 05/03/27 | 1.2 | 1.2 |
|
131.2 |
RPL07.WP4.028340 |
RPL07.Conn DHD.34 Pull Ext. Trunk (384F) [SSW<>JXSW] | SSW<>JXSW | Not Started | 05/03/27 | 05/03/27 | 1.2 | 1.2 |
|
131.2 |
RPL07.WP4.028640 |
RPL07.Conn DHD.31.10 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 05/03/27 | 05/14/27 | 12.5 | 12.5 |
|
105.0 |
RPL07.WP4.028660 |
RPL07.Conn DHD.32.14 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 05/03/27 | 05/14/27 | 12.5 | 12.5 |
|
105.0 |
RPL07.WP4.028680 |
RPL07.Conn DHD.33.17 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 05/03/27 | 05/14/27 | 12.5 | 12.5 |
|
92.5 |
RPL07.WP4.028700 |
RPL07.Conn DHD.34.21 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 05/03/27 | 05/14/27 | 12.5 | 12.5 |
|
92.5 |
RPL07.WP4.030260 |
RPL07.Conn DHD.31.10<>09 Install (A-End) Simplex Jumper (SC<>LC) [PON (Active, Across-Row)] | Across-Row | Not Started | 05/03/27 | 05/03/27 | 1.2 | 1.2 |
|
138.8 |
RPL07.WP4.030460 |
RPL07.Conn DHD.31.12<>11 Pull Simplex Jumper (SC<>LC) [PON (Active, Across-Row)] | Across-Row | Not Started | 05/03/27 | 05/05/27 | 3.8 | 3.8 |
|
136.2 |
RPL07.WP4.030560 |
RPL07.Conn DHD.33 Pull Ext. Trunk (24F) [PON (Passive, In-Rack)] | In-Rack | Not Started | 05/03/27 | 05/03/27 | 1.2 | 1.2 |
|
123.8 |
RPL07.WP4.030580 |
RPL07.Conn DHD.32.14<>13 Install (A-End) Simplex Jumper (SC<>LC) [PON (Active, Across-Row)] | Across-Row | Not Started | 05/03/27 | 05/03/27 | 1.2 | 1.2 |
|
138.8 |
RPL07.WP4.030940 |
RPL07.Conn DHD.32.16<>15 Pull Simplex Jumper (SC<>LC) [PON (Active, Across-Row)] | Across-Row | Not Started | 05/03/27 | 05/05/27 | 3.8 | 3.8 |
|
136.2 |
RPL07.WP4.031000 |
RPL07.Conn DHD.34 Pull Ext. Trunk (24F) [PON (Passive, In-Rack)] | In-Rack | Not Started | 05/03/27 | 05/03/27 | 1.2 | 1.2 |
|
123.8 |
RPL07.WP4.031920 |
RPL07.Conn DHC.25 Pull Ext. Trunk (384F) [SSW<>JXSW] | SSW<>JXSW | Not Started | 05/03/27 | 05/03/27 | 1.2 | 1.2 |
|
131.2 |
RPL07.WP4.031940 |
RPL07.Conn DHC.26 Pull Ext. Trunk (384F) [SSW<>JXSW] | SSW<>JXSW | Not Started | 05/03/27 | 05/03/27 | 1.2 | 1.2 |
|
131.2 |
RPL07.WP4.032400 |
RPL07.Conn DHC.23.10 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 05/03/27 | 05/14/27 | 12.5 | 12.5 |
|
105.0 |
RPL07.WP4.032420 |
RPL07.Conn DHC.24.14 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 05/03/27 | 05/14/27 | 12.5 | 12.5 |
|
105.0 |
RPL07.WP4.032440 |
RPL07.Conn DHC.25.17 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 05/03/27 | 05/14/27 | 12.5 | 12.5 |
|
92.5 |
RPL07.WP4.032460 |
RPL07.Conn DHC.26.21 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 05/03/27 | 05/14/27 | 12.5 | 12.5 |
|
92.5 |
RPL07.WP4.034060 |
RPL07.Conn DHA.05.17<>17 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | In-Row | Not Started | 05/03/27 | 05/03/27 | 1.2 | 1.2 |
|
63.8 |
RPL07.WP4.034080 |
RPL07.Conn DHA.06.21<>21 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | In-Row | Not Started | 05/03/27 | 05/03/27 | 1.2 | 1.2 |
|
63.8 |
RPL07.WP4.034380 |
RPL07.Conn DHA.05 Install (Z-End) Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 05/03/27 | 05/04/27 | 2.5 | 2.5 |
|
58.8 |
RPL07.WP4.034400 |
RPL07.Conn DHA.06 Install (Z-End) Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 05/03/27 | 05/04/27 | 2.5 | 2.5 |
|
58.8 |
RPL07.WP4.034460 |
RPL07.Conn DHC.23.12<>11 Pull Simplex Jumper (SC<>LC) [PON (Active, Across-Row)] | Across-Row | Not Started | 05/03/27 | 05/05/27 | 3.8 | 3.8 |
|
136.2 |
RPL07.WP4.034660 |
RPL07.Conn DHC.25 Pull Ext. Trunk (24F) [PON (Passive, In-Rack)] | In-Rack | Not Started | 05/03/27 | 05/03/27 | 1.2 | 1.2 |
|
123.8 |
RPL07.WP4.034780 |
RPL07.Conn DHC.24.16<>15 Pull Simplex Jumper (SC<>LC) [PON (Active, Across-Row)] | Across-Row | Not Started | 05/03/27 | 05/05/27 | 3.8 | 3.8 |
|
136.2 |
RPL07.WP4.034820 |
RPL07.Conn DHC.26 Pull Ext. Trunk (24F) [PON (Passive, In-Rack)] | In-Rack | Not Started | 05/03/27 | 05/03/27 | 1.2 | 1.2 |
|
123.8 |
RPL07.WP4.046920 |
RPL07.Conn BE ISP DHB.NC2 (ESL) STSW-288F (NC Passive Mesh) | Network Core 2 | Not Started | 05/03/27 | 05/05/27 | 3.8 | 3.8 |
|
142.5 |
RPL07.WP4.047760 |
RPL07.Conn BE ISP DHA.CFD4 (RSL) FTSW > STSW EX384f [Across-Row] | Across-Row | Not Started | 05/03/27 | 05/05/27 | 3.8 | 3.8 |
|
127.5 |
RPL07.WP4.047800 |
RPL07.Conn BE ISP DHA.CFD5 (RSL) FTSW > STSW EX384f [In-Row] | In-Row | Not Started | 05/03/27 | 05/05/27 | 3.8 | 3.8 |
|
127.5 |
RPL07.CON.WP3B.03660 |
RPL07.Conn EF1<>DHC.26 - WBS Summary | EF1<>DHC.26 | Not Started | 05/04/27 | 05/17/27 | 12.5 | 12.5 |
|
118.8 |
RPL07.WP3B.011600 |
RPL07.Conn EF1<>DHC.26 Pull Pigtails (384F) P1&4 (LV) | EF1<>DHC.26 | Not Started | 05/04/27 | 05/04/27 | 1.2 | 1.2 |
|
115.0 |
RPL07.WP3B.013020 |
RPL07.Conn EF1<>DHC.25 Install (A-End) Pigtails (384F) P1&4 (LV) | EF1<>DHC.25 | Not Started | 05/04/27 | 05/04/27 | 1.2 | 1.2 |
|
120.0 |
RPL07.WP3B.013720 |
RPL07.Conn EF2<>DHC.24 Install (A-End) Pigtails (384F) P2&3 (MES) | EF2<>DHC.24 | Not Started | 05/04/27 | 05/04/27 | 1.2 | 1.2 |
|
132.5 |
RPL07.WP3B.015140 |
RPL07.Conn EF2<>DHC.23 Splice (A-End) Pigtails (384F) P2&3 (MES) | EF2<>DHC.23 | Not Started | 05/04/27 | 05/11/27 | 7.5 | 7.5 |
|
121.2 |
RPL07.WP3B.016580 |
RPL07.Conn EF2<>DHC.23 Install (Z-End) Pigtails (384F) P2&3 (MES) | EF2<>DHC.23 | Not Started | 05/04/27 | 05/04/27 | 1.2 | 1.2 |
|
121.2 |
RPL07.WP3B.017480 |
RPL07.Conn EF1<>DHD.32 Test Pigtails (384F) P1&4 (MES) | EF1<>DHD.32 | Not Started | 05/04/27 | 05/05/27 | 2.5 | 2.5 |
|
128.8 |
RPL07.WP4.024760 |
RPL07.Conn DHD.31 Install (A-End) Ext. Trunk (384F) [SSW<>JXSW] | SSW<>JXSW | Not Started | 05/04/27 | 05/05/27 | 2.5 | 2.5 |
|
131.2 |
RPL07.WP4.025220 |
RPL07.Conn DHD.31 Install (A-End) Trunk (192F) [FSW<>SSW] | Trunks | Not Started | 05/04/27 | 05/05/27 | 2.5 | 2.5 |
|
133.8 |
RPL07.WP4.025760 |
RPL07.Conn DHD.31 Install (A-End) Trunk (384F) [RSW<>FSW] | RSW<>FSW | Not Started | 05/04/27 | 05/07/27 | 5.0 | 5.0 |
|
133.8 |
RPL07.WP4.028440 |
RPL07.Conn DHD.31.09 Install (A-End) Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] | Jumpers (AI Confirmed) | Not Started | 05/04/27 | 05/05/27 | 2.5 | 2.5 |
|
141.2 |
RPL07.WP4.028760 |
RPL07.Conn DHD.33 Pull Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 05/04/27 | 05/04/27 | 1.2 | 1.2 |
|
131.2 |
RPL07.WP4.028780 |
RPL07.Conn DHD.34 Pull Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 05/04/27 | 05/04/27 | 1.2 | 1.2 |
|
131.2 |
RPL07.WP4.031180 |
RPL07.Conn DHD.33.17<>17 Pull Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | Jumpers | Not Started | 05/04/27 | 05/06/27 | 3.8 | 3.8 |
|
123.8 |
RPL07.WP4.031200 |
RPL07.Conn DHD.33 Install Ext. Trunk (24F) [PON (Passive, In-Rack)] | In-Rack | Not Started | 05/04/27 | 05/06/27 | 3.8 | 3.8 |
|
140.0 |
RPL07.WP4.031500 |
RPL07.Conn DHD.34.21<>21 Pull Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | Jumpers | Not Started | 05/04/27 | 05/06/27 | 3.8 | 3.8 |
|
123.8 |
RPL07.WP4.031520 |
RPL07.Conn DHD.34 Install Ext. Trunk (24F) [PON (Passive, In-Rack)] | In-Rack | Not Started | 05/04/27 | 05/06/27 | 3.8 | 3.8 |
|
140.0 |
RPL07.WP4.032480 |
RPL07.Conn DHC.25 Pull Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 05/04/27 | 05/04/27 | 1.2 | 1.2 |
|
131.2 |
RPL07.WP4.032500 |
RPL07.Conn DHC.26 Pull Trunk (192F) [FSW<>SSW] | FSW<>SSW | Not Started | 05/04/27 | 05/04/27 | 1.2 | 1.2 |
|
131.2 |
RPL07.WP4.034700 |
RPL07.Conn DHA.05.19<>19 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | In-Row | Not Started | 05/04/27 | 05/04/27 | 1.2 | 1.2 |
|
63.8 |
RPL07.WP4.034720 |
RPL07.Conn DHA.06.23<>23 Install (Z-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | In-Row | Not Started | 05/04/27 | 05/04/27 | 1.2 | 1.2 |
|
63.8 |
RPL07.WP4.035020 |
RPL07.Conn DHC.25.17<>17 Pull Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | Jumpers | Not Started | 05/04/27 | 05/06/27 | 3.8 | 3.8 |
|
123.8 |
RPL07.WP4.035060 |
RPL07.Conn DHC.25 Install Ext. Trunk (24F) [PON (Passive, In-Rack)] | In-Rack | Not Started | 05/04/27 | 05/06/27 | 3.8 | 3.8 |
|
140.0 |
RPL07.WP4.035260 |
RPL07.Conn DHC.26.21<>21 Pull Simplex Jumper (SC<>LC) [PON (Active, In-Row)] | Jumpers | Not Started | 05/04/27 | 05/06/27 | 3.8 | 3.8 |
|
123.8 |
RPL07.WP4.035300 |
RPL07.Conn DHC.26 Install Ext. Trunk (24F) [PON (Passive, In-Rack)] | In-Rack | Not Started | 05/04/27 | 05/06/27 | 3.8 | 3.8 |
|
140.0 |
RPL07.CON.WP3B.02820 |
RPL07.Conn EF2<>DHD.34 - WBS Summary | EF2<>DHD.34 | Not Started | 05/05/27 | 05/19/27 | 13.8 | 13.8 |
|
116.2 |
RPL07.CON.WP3B.02860 |
RPL07.Conn EF1<>DHD.34 - WBS Summary | EF1<>DHD.34 | Not Started | 05/05/27 | 05/19/27 | 13.8 | 13.8 |
|
116.2 |
RPL07.CON.WP4.09660 |
RPL07.Conn B CFD5 - Deliver & Install - ORV3N (Loading at Night) | OFE- Passive In-row Racks, Racks (ORv3Ns, MCRs) & PON | Not Started | 05/05/27 | 05/14/27 | 10.0 | 10.0 |
|
31.2 |
RPL07.CON.WP4.09680 |
RPL07.Conn B CFD5 - Deliver & Assemble - PON | OFE- Passive In-row Racks, Racks (ORv3Ns, MCRs) & PON | Not Started | 05/05/27 | 05/14/27 | 10.0 | 10.0 |
|
36.2 |
RPL07.EY.DHD.01380 |
RPL07.EY.DHD - Install F/R/P Remaining Equipment Pads | Foundations | Not Started | 05/05/27 | 05/11/27 | 6.2 | 6.2 |
|
96.2 |
RPL07.INT.DHC.01680 |
RPL07.Interior.DHC - Control Fault Domain 4 - L2 Checklist Completion | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/05/27 | 06/02/27 | 25.0 | 25.0 |
|
88.8 |
RPL07.INT.EC.9060 |
RPL07.Interior.ECr LO #14 - Install Door Frame | Remaining of LO Wall #14 (Ancillary, Elec Room, Humidifier Room & IDF) | Not Started | 05/05/27 | 05/06/27 | 2.5 | 2.5 |
|
62.5 |
RPL07.INT.EC.LO.9060 |
RPL07.Interior.EC LO #14 - Fire Safing OH | Interior Leave Out Wall #14 DHD/EC for DHB&D HACs | Not Started | 05/05/27 | 05/06/27 | 2.5 | 2.5 |
|
43.8 |
RPL07.INT.ENDC.5000 |
RPL07.Interior.EC Ext. Leave Out #19 - Close Exterior Leave Out #19 (CC - South) WBS Summary | Exterior Leave Out Wall #19 EC - South for DHA&C HACs | Not Started | 05/05/27 | 07/29/27 | 75.0 | 75.0 |
|
53.8 |
RPL07.INT.ENDC.5020 |
RPL07.Interior.EC Ext. Leave Out #19 - IMP In Wall MEP | Exterior Leave Out Wall #19 EC - South for DHA&C HACs | Not Started | 05/05/27 | 05/06/27 | 2.5 | 2.5 |
|
53.8 |
RPL07.SKN.E.LO.04120 |
RPL07.SKIN.LO#19 - Install IMP Flashing & Caulking | Build back Exterior Leave Out Walls #19 (EC - South) | Not Started | 05/05/27 | 05/06/27 | 2.5 | 2.5 |
|
53.8 |
RPL07.WP3B.011760 |
RPL07.Conn EF1<>DHD.34 Pull Pigtails (384F) P1&4 (MES) | EF1<>DHD.34 | Not Started | 05/05/27 | 05/06/27 | 2.5 | 2.5 |
|
111.2 |
RPL07.WP3B.012480 |
RPL07.Conn EF2<>DHD.34 Pull Pigtails (384F) P2&3 (LV) | EF2<>DHD.34 | Not Started | 05/05/27 | 05/06/27 | 2.5 | 2.5 |
|
111.2 |
RPL07.WP3B.013040 |
RPL07.Conn EF1<>DHC.26 Install (A-End) Pigtails (384F) P1&4 (LV) | EF1<>DHC.26 | Not Started | 05/05/27 | 05/05/27 | 1.2 | 1.2 |
|
118.8 |
RPL07.WP3B.013180 |
RPL07.Conn EF1<>DHD.33 Install (A-End) Pigtails (384F) P1&4 (MES) | EF1<>DHD.33 | Not Started | 05/05/27 | 05/05/27 | 1.2 | 1.2 |
|
118.8 |