Activity ID Activity Name WBS Status Start Finish Dur (d) Rem (d) % Comp Float (d)
RPL06.CON.WP2.08840 RPL06.Conn - GSIDF/DH A1 - Install Infrastructure (Racks, Waterfalls etc.) Infrastructure Not Started 11/03/26 11/06/26 5.0 5.0
0%
137.5
RPL06.CON.WP2.11020 RPL06.Conn - GSMDF1(South)<>DH B - CFD1 Rack #01 Pull, Install & Test PON Trunks MDF1 <> DH B - Rack#01 MES side Not Started 11/03/26 11/05/26 3.8 3.8
0%
126.2
RPL06.CON.WP2.12020 RPL06.Conn - GSMDF2(North)<>DH B - CFD1 Rack #50 Pull, Install & Test PON Trunks MDF2 <> DH B - Rack#50 LV side Not Started 11/03/26 11/05/26 3.8 3.8
0%
126.2
RPL06.CON.WP2.13020 RPL06.Conn - GSMDF1(South)<>DH A - CFD1 Rack #50 Pull, Install & Test PON Trunks MDF1 <> DH A - Rack#50 LV side Not Started 11/03/26 11/05/26 3.8 3.8
0%
138.8
RPL06.CON.WP2.14020 RPL06.Conn - GSMDF2(North)<>DH A - CFD1 Rack #01 Pull, Install & Test PON Trunks MDF2 <> DH A - Rack#01 MES side Not Started 11/03/26 11/05/26 3.8 3.8
0%
138.8
RPL06.CON.WP3B.01240 RPL06.Conn EF2<>DHB.16 - WBS Summary EF2<>DHB.16 Not Started 11/03/26 11/18/26 13.8 13.8
0%
118.8
RPL06.INT.ENDC.1600 RPL06.Interior.End-Corridor - BoW - Electrical Trim Out Balance of Walls & Overhead Not Started 11/03/26 11/12/26 8.8 8.8
0%
131.2
RPL06.INT.ENDC.1620 RPL06.Interior.End-Corridor - BoW - Security Trim Out Balance of Walls & Overhead Not Started 11/03/26 11/12/26 8.8 8.8
0%
131.2
RPL06.INT.ENDC.1640 RPL06.Interior.End-Corridor - BoW - Duct Drops / Trim out Balance of Walls & Overhead Not Started 11/03/26 11/09/26 6.2 6.2
0%
131.2
RPL06.INT.ENDC.1740 RPL06.Interior.End-Corridor - BoW - Install Remaining Lights Balance of Walls & Overhead Not Started 11/03/26 11/17/26 12.5 12.5
0%
150.0
RPL06.INT.ENDC.1980 RPL06.Interior.End-Corridor - BoW - Install Balance Of Refrigerant Line Balance of Walls & Overhead Not Started 11/03/26 11/09/26 6.2 6.2
0%
158.8
RPL06.INT.SSB.14640 RPL06.Interior.SSB LO #01 to #05 - Electrical L2 Checklist Completion Finishes Not Started 11/03/26 11/17/26 12.5 12.5
0%
72.5
RPL06.INT.SSBC.01310 RPL06.Interior.SSB-Corridor - Install Lighting Fit out Not Started 11/03/26 11/12/26 8.8 8.8
0%
67.5
RPL06.WP3B.012120 RPL06.Conn EF2<>DHB.16 Pull Pigtails (384F) P2&3 (LV) EF2<>DHB.16 Not Started 11/03/26 11/04/26 2.5 2.5
0%
66.2
RPL06.WP3B.013540 RPL06.Conn EF2<>DHB.15 Install (A-End) Pigtails (384F) P2&3 (LV) EF2<>DHB.15 Not Started 11/03/26 11/03/26 1.2 1.2
0%
76.2
RPL06.WP3B.014040 RPL06.Conn EF1<>DHA.04 Splice (A-End) Pigtails (384F) P1&4 (LV) EF1<>DHA.04 Not Started 11/03/26 11/10/26 7.5 7.5
0%
135.0
RPL06.WP3B.015480 RPL06.Conn EF1<>DHA.04 Install (Z-End) Pigtails (384F) P1&4 (LV) EF1<>DHA.04 Not Started 11/03/26 11/03/26 1.2 1.2
0%
135.0
RPL06.WP4.014360 RPL06.Conn DHB.15 Pull Trunk (384F) [RSW<>FSW] Trunks Not Started 11/03/26 11/03/26 1.2 1.2
0%
88.8
RPL06.WP4.014380 RPL06.Conn DHB.16 Pull Trunk (384F) [RSW<>FSW] Trunks Not Started 11/03/26 11/03/26 1.2 1.2
0%
133.8
RPL06.WP4.014640 RPL06.Conn DHA.03.09<>09 Install (A-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] Jumpers Not Started 11/03/26 11/03/26 1.2 1.2
0%
153.8
RPL06.WP4.014660 RPL06.Conn DHA.04.13<>13 Install (A-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] Jumpers Not Started 11/03/26 11/03/26 1.2 1.2
0%
153.8
RPL06.WP4.014760 RPL06.Conn DHA.03.11<>11 Pull Simplex Jumper (SC<>LC) [PON (Active, In-Row)] Jumpers Not Started 11/03/26 11/05/26 3.8 3.8
0%
138.8
RPL06.WP4.014780 RPL06.Conn DHA.04.15<>15 Pull Simplex Jumper (SC<>LC) [PON (Active, In-Row)] Jumpers Not Started 11/03/26 11/05/26 3.8 3.8
0%
138.8
GCD.RPL06.2607 L3/L4 Start - DHB Rows 17-24 DH Not Started 11/04/26 11/04/26 0.0 0.0
0%
127.5
RPL06.CX.DHB.01110 RPL06.CX.DHB - L3/L4 - Elec. Domain 05/06 DHB ELECTRICAL Not Started 11/04/26 11/09/26 5.0 5.0
0%
41.2
RPL06.CX.DHB.01560 RPL06.CX.DHB - L3/L4 - Control Fault Domain 04 - FW Flush and Fill Control Fault Domain 4 Not Started 11/04/26 11/13/26 8.8 8.8
0%
47.5
RPL06.INT.CTRC.06900 RPL06.Interior.Center-Corridor - Final Finishes & Fixtures - Casework Restrooms Not Started 11/04/26 11/13/26 8.8 8.8
0%
37.5
RPL06.INT.CTRC.1360 RPL06.Interior.Center-Corridor - BoW - Install Split Systems/Humidifiers Balance of Walls & Overhead Not Started 11/04/26 11/10/26 6.2 6.2
0%
73.8
RPL06.WP3B.014980 RPL06.Conn EF2<>DHB.15 Splice (A-End) Pigtails (384F) P2&3 (LV) EF2<>DHB.15 Not Started 11/04/26 11/12/26 7.5 7.5
0%
76.2
RPL06.WP3B.016420 RPL06.Conn EF2<>DHB.15 Install (Z-End) Pigtails (384F) P2&3 (LV) EF2<>DHB.15 Not Started 11/04/26 11/04/26 1.2 1.2
0%
76.2
RPL06.WP4.014600 RPL06.Conn DHA.01.03 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] Jumpers (AI Confirmed) Not Started 11/04/26 11/18/26 12.5 12.5
0%
128.8
RPL06.WP4.014620 RPL06.Conn DHA.02.07 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] Jumpers (AI Confirmed) Not Started 11/04/26 11/18/26 12.5 12.5
0%
128.8
RPL06.WP4.014960 RPL06.Conn DHB.11.04 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] Jumpers (AI Confirmed) Not Started 11/04/26 11/18/26 12.5 12.5
0%
128.8
RPL06.WP4.014980 RPL06.Conn DHB.12.08 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] Jumpers (AI Confirmed) Not Started 11/04/26 11/18/26 12.5 12.5
0%
128.8
RPL06.CON.WP2.08700 RPL06.Conn - CorpNet & FacNet Available (DH B) - all IDFS WP#02 GS Not Started 11/05/26 11/05/26 0.0 0.0
0%
327.5
RPL06.Conn.MS.01000 RPL06.Conn Wifi Ready - DH B (Pred from RPL10 CorpNet needed?) Connectivity Milestones Not Started 11/05/26 11/05/26 0.0 0.0
0%
137.5
RPL06.INT.CTRC.2560 RPL06.Interior.Center-Corridor LO #10 - Install Vertical Tube Steel Support for Cable Tray (IFP Add) Remaining of LO Wall #10 (Spoke Parts & Spoke Tech) Not Started 11/05/26 11/06/26 2.5 2.5
0%
31.2
RPL06.INT.CTRC.2660 RPL06.Interior.Center-Corridor LO #10 & #12 - Install Mechanical Piping Lowside OH Interior Leave Out Wall #10, #12 (DHB/CC) Not Started 11/05/26 11/09/26 3.8 3.8
0%
2.5
RPL06.INT.CTRC.7760 RPL06.Interior.Center-Corridor LO #10 - Frame Out All Remaining Walls Remaining of LO Wall #10 (Spoke Parts & Spoke Tech) Not Started 11/05/26 11/09/26 3.8 3.8
0%
56.2
RPL06.INT.DHA.03760 RPL06.Interior.DHA - OFE - Control Fault Domain 5 (Mech Side Aisle) Control Fault Domain 5 Not Started 11/05/26 11/19/26 12.5 12.5
0%
8.8
RPL06.INT.DHD.02310 RPL06.Interior.DHD - OFE - Control Fault Domain 1 (Mech Side Aisle) Control Fault Domain 1 Not Started 11/05/26 11/20/26 13.8 13.8
0%
20.0
RPL06.INT.ENDC.1700 RPL06.Interior.End-Corridor - BoW - Plumbing Trim Out Balance of Walls & Overhead Not Started 11/05/26 11/12/26 6.2 6.2
0%
131.2
RPL06.INT.ENDC.1720 RPL06.Interior.End-Corridor - BoW - Fire Life Safety Trim Out / Fire Alarm Trim Out Balance of Walls & Overhead Not Started 11/05/26 11/16/26 8.8 8.8
0%
131.2
RPL06.INT.SBC.03980 RPL06.Interior.SSB-Corridor - BoW - Install Flooring Tiles/Resinous Flooring in specific rooms Balance of Walls & Overhead Not Started 11/05/26 11/16/26 8.8 8.8
0%
63.8
RPL06.INT.SBC.06500 RPL06.Interior.SSB-Corridor - BoW - QC Balance of Walls & Overhead Not Started 11/05/26 11/12/26 6.2 6.2
0%
66.2
RPL06.INT.SSB.01630 RPL06.Interior.SSB - Loading Dock and Storage - Final Clean Loading Dock and Storage Not Started 11/05/26 11/10/26 5.0 5.0
0%
138.8
RPL06.INT.SSBC.01490 RPL06.Interior.SSB-Corridor - Remaining Mechanical DHB OFE TIe Ins Fit out Not Started 11/05/26 11/12/26 6.2 6.2
0%
130.0
RPL06.INT.SSBC.01500 RPL06.Interior.SSB-Corridor - Remaining Electrical DHB OFE TIe Ins Fit out Not Started 11/05/26 11/12/26 6.2 6.2
0%
130.0
RPL06.WP3B.013560 RPL06.Conn EF2<>DHB.16 Install (A-End) Pigtails (384F) P2&3 (LV) EF2<>DHB.16 Not Started 11/05/26 11/05/26 1.2 1.2
0%
118.8
RPL06.WP4.015120 RPL06.Conn DHB.15.17<>17 Install (A-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] Jumpers Not Started 11/05/26 11/05/26 1.2 1.2
0%
138.8
RPL06.WP4.015140 RPL06.Conn DHB.16.21<>21 Install (A-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] Jumpers Not Started 11/05/26 11/05/26 1.2 1.2
0%
138.8
RPL06.WP4.015200 RPL06.Conn DHB.15.19<>19 Pull Simplex Jumper (SC<>LC) [PON (Active, In-Row)] Jumpers Not Started 11/05/26 11/09/26 3.8 3.8
0%
123.8
RPL06.WP4.015220 RPL06.Conn DHB.16.23<>23 Pull Simplex Jumper (SC<>LC) [PON (Active, In-Row)] Jumpers Not Started 11/05/26 11/09/26 3.8 3.8
0%
123.8
RPL06.CON.WP2.11040 RPL06.Conn - GSMDF1(South)<>DH B - CFD2 Rack #01 Pull, Install & Test PON Trunks MDF1 <> DH B - Rack#01 MES side Not Started 11/06/26 11/10/26 3.8 3.8
0%
126.2
RPL06.CON.WP2.12040 RPL06.Conn - GSMDF2(North)<>DH B - CFD2 Rack #50 Pull, Install & Test PON Trunks MDF2 <> DH B - Rack#50 LV side Not Started 11/06/26 11/10/26 3.8 3.8
0%
126.2
RPL06.CON.WP2.13040 RPL06.Conn - GSMDF1(South)<>DH A - CFD2 Rack #50 Pull, Install & Test PON Trunks MDF1 <> DH A - Rack#50 LV side Not Started 11/06/26 11/10/26 3.8 3.8
0%
138.8
RPL06.CON.WP2.14040 RPL06.Conn - GSMDF2(North)<>DH A - CFD2 Rack #01 Pull, Install & Test PON Trunks MDF2 <> DH A - Rack#01 MES side Not Started 11/06/26 11/10/26 3.8 3.8
0%
138.8
RPL06.EY.DHA.01470 RPL06.EY.DHA - Remaining L2 Checklist Completion Tie-ins Not Started 11/06/26 11/13/26 6.2 6.2
0%
125.0
RPL06.INT.DHA.01640 RPL06.Interior.DHA - Control Fault Domain 4 - Install Mechanical Side Aisle Cable Tray Remaining Tie-ins post Mech Side Aisle install Not Started 11/06/26 12/01/26 18.8 18.8
0%
63.8
RPL06.INT.DHA.01670 RPL06.Interior.DHA - Control Fault Domain 4 - Install copper from GS.IDF to BMS and EPMS panels (UG from Center IDF) Remaining Tie-ins post Mech Side Aisle install Not Started 11/06/26 12/01/26 18.8 18.8
0%
42.5
RPL06.INT.DHB.01810 RPL06.Interior.DHB - Control Fault Domain 5 - Pull BMS from panel to devices Remaining Tie-ins post Mech Side Aisle install Not Started 11/06/26 12/01/26 18.8 18.8
0%
32.5
RPL06.INT.DHB.01820 RPL06.Interior.DHB - Control Fault Domain 5 - Pull EPMS from panel to devices Remaining Tie-ins post Mech Side Aisle install Not Started 11/06/26 12/01/26 18.8 18.8
0%
32.5
RPL06.INT.DHB.01830 RPL06.Interior.DHB - Control Fault Domain 5 - Set UPS and Panel (2) Remaining Tie-ins post Mech Side Aisle install Not Started 11/06/26 12/01/26 18.8 18.8
0%
17.5
RPL06.WP3B.015000 RPL06.Conn EF2<>DHB.16 Splice (A-End) Pigtails (384F) P2&3 (LV) EF2<>DHB.16 Not Started 11/06/26 11/16/26 7.5 7.5
0%
118.8
RPL06.WP3B.016440 RPL06.Conn EF2<>DHB.16 Install (Z-End) Pigtails (384F) P2&3 (LV) EF2<>DHB.16 Not Started 11/06/26 11/06/26 1.2 1.2
0%
118.8
RPL06.WP4.010700 RPL06.Conn DHB.12.05<>05 Install (A-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] Jumpers Not Started 11/06/26 11/06/26 1.2 1.2
0%
137.5
RPL06.WP4.011780 RPL06.Conn DHB.12.07<>07 Install (A-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] Jumpers Not Started 11/06/26 11/06/26 1.2 1.2
0%
138.8
RPL06.WP4.015060 RPL06.Conn DHB.14.15 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] Jumpers (AI Confirmed) Not Started 11/06/26 11/20/26 12.5 12.5
0%
113.8
RPL06.WP4.015080 RPL06.Conn DHA.03.11<>11 Install (A-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] Jumpers Not Started 11/06/26 11/06/26 1.2 1.2
0%
151.2
RPL06.WP4.015100 RPL06.Conn DHA.04.15<>15 Install (A-End) Simplex Jumper (SC<>LC) [PON (Active, In-Row)] Jumpers Not Started 11/06/26 11/06/26 1.2 1.2
0%
151.2
RPL06.WP4.015240 RPL06.Conn DHA.03.10<>09 Pull Simplex Jumper (SC<>LC) [PON (Active, Across-Row)] Across-Row Not Started 11/06/26 11/12/26 5.0 5.0
0%
138.8
RPL06.WP4.015260 RPL06.Conn DHA.04.14<>13 Pull Simplex Jumper (SC<>LC) [PON (Active, Across-Row)] Across-Row Not Started 11/06/26 11/12/26 5.0 5.0
0%
138.8
RPL06.WP4.017020 RPL06.Conn DHB.13.11 Pull Duplex Jumper (LC<>LC) [RSW<>FSW (AI Confirmed)] Jumpers (AI Confirmed) Not Started 11/06/26 11/20/26 12.5 12.5
0%
113.8
GCD.RPL06.4645 L3/L4 Start - DHA Rows 09-16 DH Not Started 11/09/26 11/09/26 0.0 0.0
0%
136.2
GCD.RPL06.5285 L3/L4 Finish EY - DHC EY Not Started 11/09/26 11/09/26 0.0 0.0
0%
231.2
RPL06.CON.WP2.08860 RPL06.Conn - GSIDF/DH A1 - Install Cabling (Pull, Splice & terminate) Cabling Not Started 11/09/26 11/17/26 7.5 7.5
0%
316.2
RPL06.CON.WP2.08900 RPL06.Conn - GSIDF/DH A1 - Install Copper, WAPs, Security Camera & Access Control Cabling Not Started 11/09/26 11/20/26 11.2 11.2
0%
137.5
RPL06.CX.DHA.01080 RPL06.CX.DHA - L3/L4 - Elec. Domain 03/04 DHA ELECTRICAL Not Started 11/09/26 11/13/26 5.0 5.0
0%
45.0
RPL06.CX.DHA.01100 RPL06.CX.DHA - L3/L4 - Control Fault Domain 01 Control Fault Domain 1 Not Started 11/09/26 12/16/26 31.2 31.2
0%
18.8
RPL06.EY.ENDC.1970 RPL06.EY.DHD.T2 - HAC Prefab prior to install for DH C Tent 2 Not Started 11/09/26 11/16/26 6.2 6.2
0%
1.2
RPL06.INT.CTRC.2580 RPL06.Interior.Center-Corridor LO #10 - Install Horizontal Steel Supports for Cable Tray (IFP Add) Remaining of LO Wall #10 (Spoke Parts & Spoke Tech) Not Started 11/09/26 11/12/26 3.8 3.8
0%
31.2
RPL06.INT.SSB.01590 RPL06.Interior.SSB - BoW - Electrical L2 Checklist Completion Balance of Walls and OverHead Not Started 11/09/26 11/19/26 10.0 10.0
0%
120.0
GCD.RPL06.3965 L3/L4 Finish mCUP [5-6] - RPL06 mCup Not Started 11/10/26 11/10/26 0.0 0.0
0%
251.2
GCD.RPL06.5305 L3 Finish - DHC DH Not Started 11/10/26 11/10/26 0.0 0.0
0%
231.2
ICM.B6.2510.C [SSDCB1] L3/4 Start - DHC Commissioning Not Started 11/10/26 11/10/26 0.0 0.0
0%
231.2
RPL06.CON.WP4.03400 RPL06.Conn WP4 FENW DHA CFD3 Infrastructure Infrastructure Not Started 11/10/26 12/10/26 25.0 25.0
0%
126.2
RPL06.CX.DHB.01400 RPL06.CX.DHB - L3/L4 - Control Fault Domain 03 - TW Flush and Fill Control Fault Domain 3 Not Started 11/10/26 11/20/26 10.0 10.0
0%
41.2
RPL06.CX.DHC.01030 RPL06.CX.DHC - L3/L4 - House Power (for electrical) DHC HOUSE POWER Not Started 11/10/26 11/24/26 12.5 12.5
0%
100.0
RPL06.INT.CTRC.01390 RPL06.Interior.Center-Corridor (N) - Set Equipment / Interior Fit out (North) Not Started 11/10/26 11/17/26 6.2 6.2
0%
56.2
RPL06.INT.CTRC.01410 RPL06.Interior.Center-Corridor (N) - Fire Life Safe Trim Fit out (North) Not Started 11/10/26 11/16/26 5.0 5.0
0%
72.5
RPL06.INT.CTRC.1660 RPL06.Interior.Center-Corridor - BoW - Final Paint and Tube Steel Paint (IFP Add) Balance of Walls & Overhead Not Started 11/10/26 11/19/26 8.8 8.8
0%
51.2
RPL06.INT.CTRC.2680 RPL06.Interior.Center-Corridor LO #10 & #12 - Install Fire Life Safety Lowside OH Interior Leave Out Wall #10, #12 (DHB/CC) Not Started 11/10/26 11/13/26 3.8 3.8
0%
7.5
RPL06.INT.CTRC.2700 RPL06.Interior.Center-Corridor LO #10 & #12 - Install Plumbing Lowside OH Interior Leave Out Wall #10, #12 (DHB/CC) Not Started 11/10/26 11/13/26 3.8 3.8
0%
2.5
RPL06.INT.CTRC.7800 RPL06.Interior.Center-Corridor LO #10 - Install Mechanical Piping Lowside OH & In Wall Remaining of LO Wall #10 (Spoke Parts & Spoke Tech) Not Started 11/10/26 11/13/26 3.8 3.8
0%
60.0
RPL06.INT.CTRC.7820 RPL06.Interior.Center-Corridor LO #10 - Install Fire Life Safety Lowside OH & In Wall Remaining of LO Wall #10 (Spoke Parts & Spoke Tech) Not Started 11/10/26 11/13/26 3.8 3.8
0%
60.0
RPL06.INT.CTRC.7840 RPL06.Interior.Center-Corridor LO #10 - Install Plumbing Lowside OH & In Wall Remaining of LO Wall #10 (Spoke Parts & Spoke Tech) Not Started 11/10/26 11/13/26 3.8 3.8
0%
60.0
RPL06.INT.CTRC.7860 RPL06.Interior.Center-Corridor LO #10 - Install Security Lowside OH & In Wall Remaining of LO Wall #10 (Spoke Parts & Spoke Tech) Not Started 11/10/26 11/13/26 3.8 3.8
0%
60.0
RPL06.INT.CTRC.7880 RPL06.Interior.Center-Corridor LO #10 - Install Controls / EPMS / BMS OH & In Wall Remaining of LO Wall #10 (Spoke Parts & Spoke Tech) Not Started 11/10/26 11/13/26 3.8 3.8
0%
60.0
RPL06.INT.CTRC.7900 RPL06.Interior.Center-Corridor LO #10 - Install Electrical Lowside OH & In Wall Remaining of LO Wall #10 (Spoke Parts & Spoke Tech) Not Started 11/10/26 11/18/26 7.5 7.5
0%
56.2
RPL06.INT.DHA.01470 RPL06.Conn DHA - CFD3 - Set Passive Racks for WP#3b (16) Infrastructure Not Started 11/10/26 11/13/26 3.8 3.8
0%
73.8