Schedule Viewer
Last schedule upload: D3-R25005-00-RPL10 — 9281 activities — 06/03/2026 08:35 AM CT
RPL10 - GC LIVE SCHEDULE - Data Date 20260524.xer
· Uploaded Jun 03, 2026 01:35 PM
· 9281 activities
Experimental
Auto-populate checklist dates from schedule:
100
Activities Shown
0
Completed
0
In Progress
1
Critical
| Activity ID | Activity Name | WBS | Status | Start | Finish | Dur (d) | Rem (d) | % Comp | Float (d) |
|---|---|---|---|---|---|---|---|---|---|
RPL.CM.D.N5635.XR |
US 80 Turn Lane at Bypass Rd | Logistics - Off-Site Receive XREF Milsetones | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
125.0 |
RPL.CM.D.N5650.XR |
I-20 / LA 583 Right Turn Lane | Logistics - Off-Site Receive XREF Milsetones | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
125.0 |
RPL.CM.D.N5655.XR |
US 80 Traffic Signals at LA 583, LA 183 and LA 609 | Logistics - Off-Site Receive XREF Milsetones | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
125.0 |
RPL.CM.D.N5695.XR |
LA 854 - (Donahue Rd - LA183) Repaving / Overlay | Logistics - Off-Site Receive XREF Milsetones | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
857.5 |
RPL.GF.D.N0110.XR |
2 of 4 Fiber Pulls Complete (CAV1/4) MMH to GS.EF1/ Prod.EF1F | Connectivity (XREFs) | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
153.8 |
RPL.GF.D.N0120.XR |
4 of 4 Fiber Pulls Complete CAV2/3 to GS.EF2/ Prod.EF2B | Connectivity (XREFs) | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
186.2 |
RPL.GF.D.N0250.XR |
Fiber Pulls, Test & Term All Prod EF to EF Complete RPL 10 to RPL6 | Connectivity (XREFs) | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
221.2 |
RPL.GF.D.N0261.XR |
GS.IDF Hut 10-Way Install Complete (03, 04, 08, 09, 10) | Connectivity (XREFs) | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
196.2 |
RPL.GF.D.N0262.XR |
GS.IDF Hut 10-Way Install Complete (01, 02, 06, 07) | Connectivity (XREFs) | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
215.0 |
RPL.GF.D.N0263.XR |
GS.IDF Hut 10-Way Install Complete (11, 12, 13, 05) | Connectivity (XREFs) | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
857.5 |
RPL.GF.D.N0280.XR |
Fiber Pulls, Test & Term All Prod EF to EF Complete RPL 10 to AI1 | Connectivity (XREFs) | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
171.2 |
RPL.GF.D.N0520.XR |
Radio Tower(s) Available for DAS/PS - SSB, NWS1, NWS2, EF1, EF2 RPL10 ( WP3B - Successor) - Commissoning affect? | Connectivity (XREFs) | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
68.8 |
RPL.GF.D.N0530.XR |
Radio Tower(s) Available for DAS/PS - NWS3, NWS4 (WP3B-Successor) - Commissoning affect? | Connectivity (XREFs) | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
68.8 |
RPL.GF.D.N0540.XR |
GS Fiber Pulls, Test & Term Complete - NWB RPL 10 to iBOS (META's Ware House logistics) | Connectivity (XREFs) | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
186.2 |
RPL.GF.D.N0550.XR |
GS Fiber Pulls, Test & Term Complete - NWB RPL 10 to Admin Building | Connectivity (XREFs) | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
186.2 |
RPL.GF.D.N0560.XR |
GS Fiber Pulls, Test & Term Complete - NWB RPL 10 to GH1 (Guard House) | Connectivity (XREFs) | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
186.2 |
RPL.GF.D.N0570.XR |
GS Fiber Pulls, Test & Term Complete - NWB RPL 10 to GH2 (Guard House) | Connectivity (XREFs) | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
186.2 |
RPL.GF.D.N0580.XR |
GS Fiber Pulls, Test & Term Complete - NWB RPL 10 to GH3 (Guard House) | Connectivity (XREFs) | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
186.2 |
RPL.GF.D.N0600.XG |
GS.IDF Hut Install Complete (01, 02, 06, 07) | Give Milestones (XREFs) | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
857.5 |
RPL10.EY.EF1.01780 |
RPL10.EY.EF1 - FSP1 - Install Insect Screen Phase 1 | Fiber Support Platform - RPL-1 | Not Started | 05/26/26 | 06/01/26 | 6.2 | 6.2 |
|
227.5 |
RPL10.EY.EF2.01380 |
RPL10.EY.EF2 - Install EPMS Tie-ins | Tie-ins | Not Started | 05/26/26 | 06/01/26 | 6.2 | 6.2 |
|
133.8 |
RPL10.EY.EF2.01460 |
RPL10.EY.EF2 - FSP5 - Install Roofing Z Purlin (Logistic #7 Install) | Fiber Support Platform - RPL-5 | Not Started | 05/26/26 | 06/04/26 | 10.0 | 10.0 |
|
248.8 |
RPL10.EY.NS2.01290 |
RPL10.EY.NS2 - MV Loop 1 - L2 Checklist Completion | Tie-ins | Not Started | 05/26/26 | 06/08/26 | 12.5 | 12.5 |
|
31.2 |
RPL10.EY.NS3.01210 |
RPL10.EY.NS3 - Tent Temp Conditioning Startup and Available (Including Acclimation) (03/27/26) | Tent and Temp Conditions | Not Started | 05/26/26 | 06/02/26 | 7.5 | 7.5 |
|
41.2 |
RPL10.EY.NS4.01210 |
RPL10.EY.NS4 - Tent Temp Conditioning Startup and Available (Including Acclimation) (04/10/26) | Tent and Temp Conditions | Not Started | 05/26/26 | 06/02/26 | 7.5 | 7.5 |
|
86.2 |
RPL10.INT.CTRC.01460 |
RPL10.Interior.Center-Corridor - BoW - Install Lighting | Balance of Walls & OverHead | Not Started | 05/26/26 | 06/03/26 | 8.8 | 8.8 |
|
113.8 |
RPL10.INT.CTRC.07740 |
RPL10.Interior.Center-Corridor - BoW - Install Fire Alarm Panel (Fire Riser Room NS2, EF Area) | Balance of Walls & OverHead | Not Started | 05/26/26 | 05/28/26 | 3.8 | 3.8 |
|
182.5 |
RPL10.INT.EF1.01390 |
RPL10.Interior.EF1 - CFCI - Install CFCI Prefab Cable Rack - EF1 West | OFE | Not Started | 05/26/26 | 06/05/26 | 11.2 | 11.2 |
|
18.8 |
RPL10.INT.EF1.01420 |
RPL10.Interior.EF1 - EF1 East - Install Lighting | East EF-1 | Not Started | 05/26/26 | 06/10/26 | 15.0 | 15.0 |
|
113.8 |
RPL10.INT.EF1.01430 |
RPL10.Interior.EF1 - EF1 East - Pull EPMS / BMS from panel to devices | East EF-1 | Not Started | 05/26/26 | 06/01/26 | 6.2 | 6.2 |
|
122.5 |
RPL10.INT.EF1.01435 |
RPL10.Interior.EF1 - EF1 East - Install Wall Mounted Ladder Racks on Full Height EF Walls | East EF-1 | Not Started | 05/26/26 | 06/01/26 | 6.2 | 6.2 |
|
193.8 |
RPL10.INT.EF1.01440 |
RPL10.Interior.EF1 - EF1 East - Install copper from GS.IDF to BMS and EPMS panels | East EF-1 | Not Started | 05/26/26 | 06/01/26 | 6.2 | 6.2 |
|
122.5 |
RPL10.INT.EF1.01450 |
RPL10.Interior.EF1 - EF1 East - Fire Life Safety | East EF-1 | Not Started | 05/26/26 | 06/03/26 | 8.8 | 8.8 |
|
187.5 |
RPL10.INT.ENDC.01070 |
RPL10.Interior.End-Corridor - BoW - Install Door (Verify with Trades before installation) | Balance of Walls & Overhead | Not Started | 05/26/26 | 05/28/26 | 3.8 | 3.8 |
|
230.0 |
RPL10.INT.ENDC.01130 |
RPL10.Interior.End-Corridor - Install Fitout (Restroom, Janitor, Fire Riser, Humidifier) - WBS Summary | Fit out | Not Started | 05/26/26 | 05/26/26 | 0.0 | 0.0 |
|
0.0 |
RPL10.INT.NS1.01270 |
RPL10.Interior.NS1 - Control Fault Domain 6 SQ1.1 - Pull EPMS from panel to devices | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
11.2 |
RPL10.INT.NS1.01340 |
RPL10.Interior.NS1 - Control Fault Domain 6 SQ1.1 - Install copper from GS.IDF to BMS and EPMS panels | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
11.2 |
RPL10.INT.NS1.01390 |
RPL10.Interior.NS1 - Control Fault Domain 5 SQ2.1 - Pull BMS from panel to devices | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
37.5 |
RPL10.INT.NS1.01400 |
RPL10.Interior.NS1 - Control Fault Domain 5 SQ2.1 - Pull EPMS from panel to devices | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
37.5 |
RPL10.INT.NS1.01410 |
RPL10.Interior.NS1 - Control Fault Domain 5 SQ2.1 - Set UPS and Panel (2) | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
21.2 |
RPL10.INT.NS1.01450 |
RPL10.Interior.NS1 - Control Fault Domain 5 SQ2.1 - Install Mechanical Side Aisle Cable Tray | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
21.2 |
RPL10.INT.NS1.01500 |
RPL10.Interior.NS1 - Control Fault Domain 4 SQ3.1 - Install Vesda / FA | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
41.2 |
RPL10.INT.NS1.01510 |
RPL10.Interior.NS1 - Control Fault Domain 4 SQ3.1 - Install FW | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
35.0 |
RPL10.INT.NS1.01640 |
RPL10.Interior.NS1 - Control Fault Domain 3 SQ4.1 - Install Vesda / FA | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
51.2 |
RPL10.INT.NS1.01650 |
RPL10.Interior.NS1 - Control Fault Domain 3 SQ4.1 - Install FW | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
45.0 |
RPL10.INT.NS1.01750 |
RPL10.Interior.NS1 - Control Fault Domain 3 SQ4.1 - Install LV Side Aisle Cable Tray | LV Side Tie-ins | Not Started | 05/26/26 | 05/29/26 | 5.0 | 5.0 |
|
77.5 |
RPL10.INT.NS1.01780 |
RPL10.Interior.NS1 - Control Fault Domain 2 SQ5.1 - Install Vesda / FA | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
61.2 |
RPL10.INT.NS1.01790 |
RPL10.Interior.NS1 - Control Fault Domain 2 SQ5.1 - Install FW | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
55.0 |
RPL10.INT.NS1.02260 |
RPL10.Interior.NS1 - Control Fault Domain 3 SQ4.1 - Install TW | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
45.0 |
RPL10.INT.NS1.02280 |
RPL10.Interior.NS1 - Control Fault Domain 2 SQ5.1 - Install TW | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
55.0 |
RPL10.INT.NS1.02680 |
RPL10.Interior.NS1 - OFE - Control Fault Domain 2 SQ5.1 (Mech Side Aisle) | OFE NS1 Control Fault Domain 2 | Not Started | 05/26/26 | 06/11/26 | 16.2 | 16.2 |
|
38.8 |
RPL10.INT.NS1.02800 |
RPL10.Interior.NS1 - Control Fault Domain 2 SQ5.1 - Install Duct (MES Side) | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
55.0 |
RPL10.INT.NS1.03220 |
RPL10.Interior.NS1 - Control Fault Domain 1 SQ6.1 - Install HAC Busway and Cable Tray Tie-In | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
77.5 |
RPL10.INT.NS1.03240 |
RPL10.Interior.NS1 - Control Fault Domain 2 SQ5.1 - Install HAC Busway and Cable Tray Tie-In | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
67.5 |
RPL10.INT.NS1.03260 |
RPL10.Interior.NS1 - Control Fault Domain 3 SQ4.1 - Install HAC Busway and Cable Tray Tie-In | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
57.5 |
RPL10.INT.NS2.01170 |
RPL10.Interior.NS2 - Control Fault Domain 6 SQ1.2 - Pull BMS from panel to devices | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
21.2 |
RPL10.INT.NS2.01180 |
RPL10.Interior.NS2 - Control Fault Domain 6 SQ1.2 - Pull EPMS from panel to devices | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
21.2 |
RPL10.INT.NS2.01190 |
RPL10.Interior.NS2 - Control Fault Domain 6 SQ1.2 - Set TWMS, UPS and Panel (2) | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
8.8 |
RPL10.INT.NS2.01280 |
RPL10.Interior.NS2 - Control Fault Domain 5 SQ2.2 - Install FW | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
12.5 |
RPL10.INT.NS2.01310 |
RPL10.Interior.NS2 - Control Fault Domain 5 SQ2.2 - Pull BMS from panel to devices | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
31.2 |
RPL10.INT.NS2.01320 |
RPL10.Interior.NS2 - Control Fault Domain 5 SQ2.2 - Pull EPMS from panel to devices | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
31.2 |
RPL10.INT.NS2.01380 |
RPL10.Interior.NS2 - Control Fault Domain 5 SQ2.2 - Install LV Side Aisle Cable Tray | LV Side Tie-ins | Not Started | 05/26/26 | 05/29/26 | 5.0 | 5.0 |
|
25.0 |
RPL10.INT.NS2.01410 |
RPL10.Interior.NS2 - Control Fault Domain 4 SQ3.2 - Install Vesda / FA | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
35.0 |
RPL10.INT.NS2.01420 |
RPL10.Interior.NS2 - Control Fault Domain 4 SQ3.2 - Install FW | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
28.8 |
RPL10.INT.NS2.02220 |
RPL10.Interior.NS2 - Control Fault Domain 4 SQ3.2 - Install TW | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
28.8 |
RPL10.INT.NS2.02845 |
RPL10.Interior.NS2 - Control Fault Domain 4 SQ3.2 - Install Duct (MES Side) | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
28.8 |
RPL10.INT.NS2.03365 |
RPL10.Interior.NS2 - Control Fault Domain 5 SQ2.2 - Install HAC Busway and Cable Tray Tie-In | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
31.2 |
RPL10.INT.NS2.03385 |
RPL10.Interior.NS2 - Control Fault Domain 4 SQ3.2 - Install HAC Busway and Cable Tray Tie-In | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
41.2 |
RPL10.INT.NS2.03405 |
RPL10.Interior.NS2 - Control Fault Domain 3 SQ4.2 - Install HAC Busway and Cable Tray Tie-In | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
51.2 |
RPL10.INT.NS2.03425 |
RPL10.Interior.NS2 - Control Fault Domain 2 SQ5.2 - Install HAC Busway and Cable Tray Tie-In | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
61.2 |
RPL10.INT.NS2.03445 |
RPL10.Interior.NS2 - Control Fault Domain 1 SQ6.2 - Install HAC Busway and Cable Tray Tie-In | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
71.2 |
RPL10.INT.NS3.01094 |
RPL10.Interior.NS3 - Electrical Panels/Ancillary Skid (ATS,SB House,MCB,MLO, Transformer) - Tie-Ins | NS3 - LV Skids and TopHat | Not Started | 05/26/26 | 06/15/26 | 18.8 | 18.8 |
|
157.5 |
RPL10.INT.NS4.01094 |
RPL10.Interior.NS4 - Electrical Panels/Ancillary Skid (ATS,SB House,MCB,MLO, Transformer) - Tie-Ins | NS4 - LV Skids and TopHat | Not Started | 05/26/26 | 06/15/26 | 18.8 | 18.8 |
|
143.8 |
RPL10.INT.NS4.01160 |
RPL10.Interior.NS4 - Tie-ins - Control Fault Domain 1 SQ7.1 - WBS Summary | Tie-Ins NS4 Control Fault Domain 1 | Not Started | 05/26/26 | 09/17/26 | 101.2 | 101.2 |
|
80.0 |
RPL10.INT.NS4.01300 |
RPL10.Interior.NS4 - Tie-ins - Control Fault Domain 2 SQ8.1 - WBS Summary | Tie-Ins NS4 Control Fault Domain 2 | Not Started | 05/26/26 | 09/24/26 | 107.5 | 107.5 |
|
83.8 |
RPL10.INT.NS4.01440 |
RPL10.Interior.NS4 - Tie-ins - Control Fault Domain 3 SQ9.1 (including IDF) - WBS Summary | Tie-Ins NS4 Control Fault Domain 3 | Not Started | 05/26/26 | 10/13/26 | 123.8 | 123.8 |
|
82.5 |
RPL10.INT.NS4.03100 |
RPL10.Interior.NS4 - Control Fault Domain 1 SQ7.1 - Install HAC Busway and Cable Tray Tie-In | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
150.0 |
RPL10.INT.NS4.03120 |
RPL10.Interior.NS4 - Control Fault Domain 2 SQ8.1 - Install HAC Busway and Cable Tray Tie-In | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
160.0 |
RPL10.INT.NS4.03140 |
RPL10.Interior.NS4 - Control Fault Domain 3 SQ9.1 - Install HAC Busway and Cable Tray Tie-In | Remaining Tie-ins post Mech Side Aisle install | Not Started | 05/26/26 | 06/22/26 | 25.0 | 25.0 |
|
175.0 |
RPL10.INT.SSB.01420 |
RPL10.Interior.SSB - Loading Dock and Storage - Install Dock Levelers, Pads, Lock (Mob 1) | Loading Dock and Storage | Not Started | 05/26/26 | 05/27/26 | 2.5 | 2.5 |
|
153.8 |
RPL10.INT.SSB.01560 |
RPL10.Interior.SSB - BoW - Install Asset Tags & QC | Balance of Walls and OverHead | Not Started | 05/26/26 | 06/03/26 | 8.8 | 8.8 |
|
165.0 |
RPL10.INT.SSBC.01390 |
RPL10.Interior.SSB-Corridor - BoW - Install Battery | Balance of Walls & OverHead | Not Started | 05/26/26 | 06/08/26 | 12.5 | 12.5 |
|
102.5 |
RPL10.INT.SSBC.02980 |
RPL10.Interior.SSB-Corridor - BoW - Install Lights | Balance of Walls & OverHead | Not Started | 05/26/26 | 06/01/26 | 6.2 | 6.2 |
|
108.8 |
RPL10.INT.SSBC.03000 |
RPL10.Interior.SSB-Corridor - BoW - Security Trim Out | Balance of Walls & OverHead | Not Started | 05/26/26 | 06/03/26 | 8.8 | 8.8 |
|
122.5 |
RPL10.OFCI.4000 |
OFCI - Delivery ROJ: FE Fiber for CFD NS1.6 (ROJ ) (RVCD ) | NS1 | Not Started | 05/26/26 | 06/15/26 | 18.8 | 18.8 |
|
23.8 |
RPL10.OFCI.6840 |
OFCI - Delivery ROJ: FE Fiber for CFD NS1.5 (ROJ ) (RVCD ) | NS1 | Not Started | 05/26/26 | 06/15/26 | 18.8 | 18.8 |
|
31.2 |
RPL10.OFCI.6860 |
OFCI - Delivery ROJ: FE Fiber for CFD NS1.4 (ROJ ) (RVCD ) | NS1 | Not Started | 05/26/26 | 06/15/26 | 18.8 | 18.8 |
|
58.8 |
RPL10.OFCI.6880 |
OFCI - Delivery ROJ: FE Fiber for CFD NS1.3 (ROJ ) (RVCD ) | NS1 | Not Started | 05/26/26 | 06/15/26 | 18.8 | 18.8 |
|
85.0 |
RPL10.OFCI.6900 |
OFCI - Delivery ROJ: FE Fiber for CFD NS1.2 (ROJ ) (RVCD ) | NS1 | Not Started | 05/26/26 | 06/15/26 | 18.8 | 18.8 |
|
111.2 |
RPL10.OFCI.6920 |
OFCI - Delivery ROJ: FE Fiber for CFD NS1.1 (ROJ ) (RVCD ) | NS1 | Not Started | 05/26/26 | 06/15/26 | 18.8 | 18.8 |
|
111.2 |
RPL10.OFCI.6940 |
OFCI - Delivery ROJ: FE Fiber for CFD NS2.6 (ROJ ) (RVCD ) | NS2 | Not Started | 05/26/26 | 06/15/26 | 18.8 | 18.8 |
|
37.5 |
RPL10.OFCI.6960 |
OFCI - Delivery ROJ: FE Fiber for CFD NS2.5 (ROJ ) (RVCD ) | NS2 | Not Started | 05/26/26 | 06/15/26 | 18.8 | 18.8 |
|
45.0 |
RPL10.OFCI.6980 |
OFCI - Delivery ROJ: FE Fiber for CFD NS2.4 (ROJ ) (RVCD ) | NS2 | Not Started | 05/26/26 | 06/15/26 | 18.8 | 18.8 |
|
71.2 |
RPL10.OFCI.7000 |
OFCI - Delivery ROJ: FE Fiber for CFD NS2.3 (ROJ ) (RVCD ) | NS2 | Not Started | 05/26/26 | 06/15/26 | 18.8 | 18.8 |
|
98.8 |
RPL10.OFCI.7020 |
OFCI - Delivery ROJ: FE Fiber for CFD NS2.2 (ROJ ) (RVCD ) | NS2 | Not Started | 05/26/26 | 06/15/26 | 18.8 | 18.8 |
|
122.5 |
RPL10.SSBC.BB.3315 |
RPL10.Int.Build Back.SSB-Corr - LO #2,3 - Coiling Door | Build Back Interior Leave Out Wall #2 #3 #4 (SSB Corr) | Not Started | 05/26/26 | 06/01/26 | 6.2 | 6.2 |
|
177.5 |
RPL10.WP2.01000 |
RPL10.Conn SSB - Install GS Cabling Pull/Term/Test (GSMDF Cross Connects) (2x GSMDF) ~120 LF | WP2 (GS/CARRIER/SFZ - INF, CAB [ISP/OSP], NET) | Not Started | 05/26/26 | 07/07/26 | 37.5 | 37.5 |
|
31.2 |
RPL10.WP2.01050 |
RPL10.Conn SSB - Install GS Cabling - Misc Scope (ME to Confirm) | WP2 (GS/CARRIER/SFZ - INF, CAB [ISP/OSP], NET) | Not Started | 05/26/26 | 06/08/26 | 12.5 | 12.5 |
|
56.2 |
RPL10.WP2.EF1.1020 |
RPL10.Conn GS.EF1 Install Cabling (Pull, Splice & Terminate) | Cabling | Not Started | 05/26/26 | 05/29/26 | 5.0 | 5.0 |
|
186.2 |
RPL10.WP2.EF1.1160 |
RPL10.Conn GS.EF1 Install Cabling for Path1 from (CAV 1/4) MMH to GS.EF (Pull, Splice & Terminate) | Cabling | Not Started | 05/26/26 | 05/29/26 | 5.0 | 5.0 |
|
156.2 |