Schedule Viewer
Last schedule upload: D3-R25005-00-RPL10 — 9281 activities — 06/03/2026 08:35 AM CT
RPL10 - GC LIVE SCHEDULE - Data Date 20260524.xer
· Uploaded Jun 03, 2026 01:35 PM
· 9281 activities
Experimental
Auto-populate checklist dates from schedule:
100
Activities Shown
0
Completed
0
In Progress
3
Critical
| Activity ID | Activity Name | WBS | Status | Start | Finish | Dur (d) | Rem (d) | % Comp | Float (d) |
|---|---|---|---|---|---|---|---|---|---|
RPL10.WP4.025140 |
RPL10.Conn NS2.CFD1.41<>41 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 10/21/26 | 10/21/26 | 1.2 | 1.2 |
|
68.8 |
RPL10.WP4.026320 |
RPL10.Conn NS4.CFD1.04<>03 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 10/21/26 | 10/21/26 | 1.2 | 1.2 |
|
175.0 |
RPL10.WP4.031400 |
RPL10.Conn NS3.CFD3.48<>46-49 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 10/21/26 | 10/21/26 | 1.2 | 1.2 |
|
163.8 |
RPL10.WP4.031680 |
RPL10.Conn NS3.CFD5.48<>16-20 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 10/21/26 | 10/26/26 | 5.0 | 5.0 |
|
138.8 |
RPL10.WP4.033220 |
RPL10.Conn NS2.CFD2.37 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install Duplex Jumper [MA<>JXSW] | Not Started | 10/21/26 | 10/22/26 | 2.5 | 2.5 |
|
68.8 |
RPL10.WP4.034620 |
RPL10.Conn NS2.CFD1 Pull/Install Trunk (384F) [BB<>EB] | [BB<>EB] | Not Started | 10/21/26 | 10/30/26 | 10.0 | 10.0 |
|
-2.5 |
RPL10.WP4.04980 |
RPL10.Conn NS3.CFD2.12 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] | Pull Duplex Jumper [MA<>JXSW] | Not Started | 10/21/26 | 10/23/26 | 3.8 | 3.8 |
|
167.5 |
RPL10.WP4.08580 |
RPL10.Conn NS1.CFD1.45<>46 Pull/Install Ext. Trunk (192F) [MA<>EB] | [MA<>EB] | Not Started | 10/21/26 | 10/22/26 | 2.5 | 2.5 |
|
18.8 |
RPL10.WP4.09620 |
RPL10.Conn NS2.CFD6 Pull/Install Trunk (384F) [EB<>DR] | [EB<>DR] | Not Started | 10/21/26 | 10/23/26 | 3.8 | 3.8 |
|
75.0 |
RPL10.WP4.NS4.01240 |
RPL10.Conn NS4.CFD1 GSMDF <> Network Suites Management Trunks | Post ORv3 Rack | Not Started | 10/21/26 | 10/23/26 | 3.8 | 3.8 |
|
90.0 |
GCD.RPL10.5285 |
L3/L4 Finish EY - NS3 | EY | Not Started | 10/22/26 | 10/22/26 | 0.0 | 0.0 |
|
175.0 |
RPL10.3B.FE.1F.43.2. |
Test Ext. Trunk (288F) EF1F<>NS4.CFD3 (P2-3) [SSW<>JXSW] (( AI SCOPE)) (RPL1) | Cabling (ISP) P2&3 | Not Started | 10/22/26 | 10/29/26 | 7.5 | 7.5 |
|
440.0 |
RPL10.3B.FE.1F.44.-3 |
Install Ext. Trunk (288F) EF1F<>NS4.CFD4 (P2-3) [SSW<>JXSW] (( AI SCOPE)) (RPL1) | Cabling (ISP) P2&3 | Not Started | 10/22/26 | 10/29/26 | 7.5 | 7.5 |
|
440.0 |
RPL10.CX.NS3.01070 |
RPL10.CX.NS3 - L3/L4 - UPS Start-up | NS3 ELECTRICAL | Not Started | 10/22/26 | 01/11/27 | 66.2 | 66.2 |
|
96.2 |
RPL10.CX.NS3.01560 |
RPL10.CX.NS3 - L3/L4 - Control Fault Domain 4 - FW Flush and Fill | NS3 Control Fault Domain 4 | Not Started | 10/22/26 | 10/30/26 | 8.8 | 8.8 |
|
110.0 |
RPL10.INT.NS3.01780 |
RPL10.Interior.NS3 - Control Fault Domain 5 SQ11.2 - Install Mechanical Side Aisle Cable Tray | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/22/26 | 11/19/26 | 25.0 | 25.0 |
|
40.0 |
RPL10.INT.NS3.01840 |
RPL10.Interior.NS3 - Control Fault Domain 6 SQ12.2 - Install Vesda / FA | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/22/26 | 11/19/26 | 25.0 | 25.0 |
|
55.0 |
RPL10.INT.NS3.02840 |
RPL10.Interior.NS3 - OFE - Control Fault Domain 6 SQ12.2 (Mech Side Aisle) | OFE NS3 Control Fault Domain 6 | Not Started | 10/22/26 | 11/02/26 | 10.0 | 10.0 |
|
55.0 |
RPL10.INT.NS3.02960 |
RPL10.Interior.NS3 - Control Fault Domain 6 SQ12.2 - Install Duct (MES Side) | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/22/26 | 11/19/26 | 25.0 | 25.0 |
|
55.0 |
RPL10.INT.NS4.01480 |
RPL10.Conn NS4.CFD3 - Set Passive Racks for WP3B | Infrastructure | Not Started | 10/22/26 | 10/26/26 | 3.8 | 3.8 |
|
17.5 |
RPL10.INT.NS4.03000 |
RPL10.Conn NS4.CFD3 - Set Passive Racks for PON | Infrastructure | Not Started | 10/22/26 | 10/26/26 | 3.8 | 3.8 |
|
162.5 |
RPL10.W3B.FE.011521 |
RPL10.Conn EF2F<>NS3.CFD2 (P1-4) Pull Fiber Trunk (288F) [EF<>JXSW] | EF2F<>NS3.2 (P1-4) [EF<>JXSW] | Not Started | 10/22/26 | 10/23/26 | 2.5 | 2.5 |
|
0.0 |
RPL10.W3B.FE.011661 |
RPL10.Conn EF1F<>NS4.CFD3 (P2-3) Pull Fiber Trunk (384F) [EF<>SSW] | EF1F<>NS4.3 (P2-3) [EF<>SSW] | Not Started | 10/22/26 | 10/23/26 | 2.5 | 2.5 |
|
83.8 |
RPL10.W3B.FE.011781 |
RPL10.Conn EF2F<>NS4.CFD3 (P1-4) Pull Fiber Trunk (384F) [EF<>SSW] | EF2F<>NS4.3 (P1-4) [EF<>SSW] | Not Started | 10/22/26 | 10/23/26 | 2.5 | 2.5 |
|
75.0 |
RPL10.W3B.FE.012316 |
RPL10.Conn EF2F<>NS2.CFD2 (P1-4) Install Fiber Trunk (288F) [EF<>JXSW] | EF2F<>NS2.5 (P1-4) [EF<>JXSW] | Not Started | 10/22/26 | 10/26/26 | 3.8 | 3.8 |
|
21.2 |
RPL10.W3B.FE.012931 |
RPL10.Conn EF2B<>NS2.CFD2 (P1-4) Test Fiber Trunk (384F) [EF<>SSW] | EF2B<>NS2.5 (P1-4) [EF<>SSW] | Not Started | 10/22/26 | 10/23/26 | 2.5 | 2.5 |
|
25.0 |
RPL10.WP2.GSIDF.1880 |
RPL10.Conn GSIDFN32 Install Cabling (Pull, Splice & terminate) | Cabling | Not Started | 10/22/26 | 11/04/26 | 12.5 | 12.5 |
|
76.2 |
RPL10.WP3A.EF1B.1155 |
RPL10.Conn EF1B(OPE)<>EF2B(MBOX) Pull/Install/Test OSP Cabling (for RPL07) - P4 | EF1B<>EF2B | Not Started | 10/22/26 | 11/02/26 | 10.0 | 10.0 |
|
142.5 |
RPL10.WP3A.EF2B.1110 |
RPL10.Conn EF2B(OPE)<>EF1F(MBOX) Pull/Install/Test OSP Cabling (for RPL09) - P3 | EF2B<>EF2F | Not Started | 10/22/26 | 10/29/26 | 7.5 | 7.5 |
|
137.5 |
RPL10.WP3B.FE.02540 |
RPL10.Conn EF2F<>NS4.CFD3 (P1-4) Pull/Install/Test - WBS Summary | EF2F<>NS4.3 (P1-4) [EF<>SSW] | Not Started | 10/22/26 | 11/05/26 | 13.8 | 13.8 |
|
81.2 |
RPL10.WP3B.FE.02620 |
RPL10.Conn EF1F<>NS4.CFD3 (P2-3) Pull/Install/Test - WBS Summary* | EF1F<>NS4.3 (P2-3) [EF<>SSW] | Not Started | 10/22/26 | 11/20/26 | 26.2 | 26.2 |
|
78.8 |
RPL10.WP3B.FE.08220 |
RPL10.Conn EF2F<>NS3.CFD2 (P1-4) Pull/Install/Test - WBS Summary | EF2F<>NS3.2 (P1-4) [EF<>JXSW] | Not Started | 10/22/26 | 11/03/26 | 11.2 | 11.2 |
|
18.8 |
RPL10.WP4.013020 |
RPL10.Conn NS1.CFD1.45<>45 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 10/22/26 | 10/26/26 | 3.8 | 3.8 |
|
55.0 |
RPL10.WP4.013060 |
RPL10.Conn NS1.CFD1.47<>47 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 10/22/26 | 10/26/26 | 3.8 | 3.8 |
|
57.5 |
RPL10.WP4.014300 |
RPL10.Conn NS3.CFD2.13<>13 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 10/22/26 | 10/23/26 | 2.5 | 2.5 |
|
182.5 |
RPL10.WP4.014340 |
RPL10.Conn NS3.CFD2.15<>15 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 10/22/26 | 10/23/26 | 2.5 | 2.5 |
|
185.0 |
RPL10.WP4.015420 |
RPL10.Conn NS4.CFD3.21<>21 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 10/22/26 | 10/26/26 | 3.8 | 3.8 |
|
168.8 |
RPL10.WP4.015460 |
RPL10.Conn NS4.CFD3.23<>23 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 10/22/26 | 10/26/26 | 3.8 | 3.8 |
|
171.2 |
RPL10.WP4.017020 |
RPL10.Conn NS1.CFD3.30 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install (A-End/Passive) Duplex Jumper [MA<>JXSW] | Not Started | 10/22/26 | 10/23/26 | 2.5 | 2.5 |
|
58.8 |
RPL10.WP4.017180 |
RPL10.Conn NS1.CFD3.48<>26-30 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 10/22/26 | 10/23/26 | 2.5 | 2.5 |
|
53.8 |
RPL10.WP4.023680 |
RPL10.Conn NS1.CFD5.16<>15 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 10/22/26 | 10/22/26 | 1.2 | 1.2 |
|
65.0 |
RPL10.WP4.023800 |
RPL10.Conn NS1.CFD4.22<>21 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 10/22/26 | 10/22/26 | 1.2 | 1.2 |
|
62.5 |
RPL10.WP4.024080 |
RPL10.Conn NS1.CFD2.36<>35 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 10/22/26 | 10/22/26 | 1.2 | 1.2 |
|
60.0 |
RPL10.WP4.024200 |
RPL10.Conn NS1.CFD1.42<>41 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 10/22/26 | 10/22/26 | 1.2 | 1.2 |
|
57.5 |
RPL10.WP4.024800 |
RPL10.Conn NS2.CFD4.24<>23 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 10/22/26 | 10/22/26 | 1.2 | 1.2 |
|
76.2 |
RPL10.WP4.024920 |
RPL10.Conn NS2.CFD3.30<>29 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 10/22/26 | 10/22/26 | 1.2 | 1.2 |
|
73.8 |
RPL10.WP4.025060 |
RPL10.Conn NS2.CFD2.37<>37 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 10/22/26 | 10/22/26 | 1.2 | 1.2 |
|
72.5 |
RPL10.WP4.025160 |
RPL10.Conn NS2.CFD1.42<>41 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 10/22/26 | 10/22/26 | 1.2 | 1.2 |
|
68.8 |
RPL10.WP4.026340 |
RPL10.Conn NS4.CFD1.05<>05 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 10/22/26 | 10/22/26 | 1.2 | 1.2 |
|
175.0 |
RPL10.WP4.030540 |
RPL10.Conn NS4.CFD5.48<>31-35 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 10/22/26 | 10/26/26 | 3.8 | 3.8 |
|
140.0 |
RPL10.WP4.030740 |
RPL10.Conn NS4.CFD6.48<>31-35 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 10/22/26 | 10/26/26 | 3.8 | 3.8 |
|
140.0 |
RPL10.WP4.031520 |
RPL10.Conn NS3.CFD4.48<>26-30 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 10/22/26 | 10/27/26 | 5.0 | 5.0 |
|
147.5 |
RPL10.WP4.05280 |
RPL10.Conn NS3.CFD3.17 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] | Pull Duplex Jumper [MA<>JXSW] | Not Started | 10/22/26 | 10/26/26 | 3.8 | 3.8 |
|
155.0 |
RPL10.WP4.05440 |
RPL10.Conn NS3.CFD3.48<>03-05 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 10/22/26 | 10/26/26 | 3.8 | 3.8 |
|
163.8 |
RPL10.WP4.05460 |
RPL10.Conn NS3.CFD3.48<>06-10 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 10/22/26 | 10/26/26 | 3.8 | 3.8 |
|
165.0 |
RPL10.WP4.05480 |
RPL10.Conn NS3.CFD3.48<>11-15 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 10/22/26 | 10/29/26 | 7.5 | 7.5 |
|
165.0 |
RPL10.WP4.07540 |
RPL10.Conn NS4.CFD4.28 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] | Pull Duplex Jumper [MA<>JXSW] | Not Started | 10/22/26 | 10/26/26 | 3.8 | 3.8 |
|
153.8 |
RPL10.WP4.NS3.01880 |
RPL10.Conn NS3.CFD3 Infrastructure - WBS Summary | Infrastructure | Not Started | 10/22/26 | 10/27/26 | 5.0 | 5.0 |
|
75.0 |
RPL10.WP4.NS3.01900 |
RPL10.Conn NS3.CFD3 Infrastructure | Infrastructure | Not Started | 10/22/26 | 10/27/26 | 5.0 | 5.0 |
|
75.0 |
RPL10.Conn.MS.01110 |
CorpNet & FacNet Available - NS4 | Network Suite 4 | Not Started | 10/23/26 | 10/23/26 | 0.0 | 0.0 |
|
91.2 |
RPL10.EY.NS4.01370 |
RPL10.EY.NS4 - Demo of Tent SOG | Tent and Temp Conditions | Not Started | 10/23/26 | 10/29/26 | 6.2 | 6.2 |
|
116.2 |
RPL10.W3B.FE.011216 |
RPL10.Conn EF1B<>NS2.CFD1 (P2-3) Pull Fiber Trunk (384F) [EF<>SSW] | EF1B<>NS2.6 (P2-3) [EF<>SSW] | Not Started | 10/23/26 | 10/27/26 | 3.8 | 3.8 |
|
38.8 |
RPL10.W3B.FE.011981 |
RPL10.Conn EF1B<>NS1.CFD2 (P2-3) Install Fiber Trunk (384F) [EF<>SSW] | EF1B<>NS1.5 (P2-3) [EF<>SSW] | Not Started | 10/23/26 | 10/26/26 | 2.5 | 2.5 |
|
18.8 |
RPL10.W3B.FE.012616 |
RPL10.Conn EF1B<>NS1.CFD2 (P2-3) Test Fiber Trunk (288F) [EF<>JXSW] | EF1B<>NS1.5 (P2-3) [EF<>JXSW] | Not Started | 10/23/26 | 10/26/26 | 2.5 | 2.5 |
|
20.0 |
RPL10.WP3B.FE.09280 |
RPL10.Conn EF1B<>NS2.CFD1 (P2-3) Pull/Install/Test - WBS Summary | EF1B<>NS2.6 (P2-3) [EF<>SSW] | Not Started | 10/23/26 | 11/24/26 | 27.5 | 27.5 |
|
21.2 |
RPL10.WP4.012880 |
RPL10.Conn NS1.CFD2.38<>37 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 10/23/26 | 10/27/26 | 3.8 | 3.8 |
|
57.5 |
RPL10.WP4.012920 |
RPL10.Conn NS1.CFD2.40<>39 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 10/23/26 | 10/27/26 | 3.8 | 3.8 |
|
60.0 |
RPL10.WP4.014000 |
RPL10.Conn NS2.CFD1.46<>45 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 10/23/26 | 10/27/26 | 3.8 | 3.8 |
|
68.8 |
RPL10.WP4.014040 |
RPL10.Conn NS2.CFD1.48<>47 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 10/23/26 | 10/27/26 | 3.8 | 3.8 |
|
71.2 |
RPL10.WP4.018820 |
RPL10.Conn NS2.CFD3.27 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install (A-End/Passive) Duplex Jumper [MA<>JXSW] | Not Started | 10/23/26 | 10/26/26 | 2.5 | 2.5 |
|
61.2 |
RPL10.WP4.018980 |
RPL10.Conn NS2.CFD3.48<>11-15 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 10/23/26 | 10/26/26 | 2.5 | 2.5 |
|
56.2 |
RPL10.WP4.019700 |
RPL10.Conn NS3.CFD1.48<>03-05 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 10/23/26 | 10/26/26 | 2.5 | 2.5 |
|
166.2 |
RPL10.WP4.021740 |
RPL10.Conn NS4.CFD2.09 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install (A-End/Passive) Duplex Jumper [MA<>JXSW] | Not Started | 10/23/26 | 10/26/26 | 2.5 | 2.5 |
|
158.8 |
RPL10.WP4.021900 |
RPL10.Conn NS4.CFD2.48<>03-05 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 10/23/26 | 10/26/26 | 2.5 | 2.5 |
|
153.8 |
RPL10.WP4.023820 |
RPL10.Conn NS1.CFD4.23<>23 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 10/23/26 | 10/23/26 | 1.2 | 1.2 |
|
62.5 |
RPL10.WP4.024100 |
RPL10.Conn NS1.CFD2.37<>37 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 10/23/26 | 10/23/26 | 1.2 | 1.2 |
|
60.0 |
RPL10.WP4.024220 |
RPL10.Conn NS1.CFD1.43<>43 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 10/23/26 | 10/23/26 | 1.2 | 1.2 |
|
57.5 |
RPL10.WP4.024940 |
RPL10.Conn NS2.CFD3.31<>31 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 10/23/26 | 10/23/26 | 1.2 | 1.2 |
|
73.8 |
RPL10.WP4.025180 |
RPL10.Conn NS2.CFD1.43<>43 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 10/23/26 | 10/23/26 | 1.2 | 1.2 |
|
68.8 |
RPL10.WP4.026360 |
RPL10.Conn NS4.CFD1.06<>05 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 10/23/26 | 10/23/26 | 1.2 | 1.2 |
|
175.0 |
RPL10.WP4.033240 |
RPL10.Conn NS2.CFD2.38 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install Duplex Jumper [MA<>JXSW] | Not Started | 10/23/26 | 10/26/26 | 2.5 | 2.5 |
|
68.8 |
RPL10.WP4.05500 |
RPL10.Conn NS3.CFD3.48<>16-20 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 10/23/26 | 10/29/26 | 6.2 | 6.2 |
|
167.5 |
RPL10.WP4.05520 |
RPL10.Conn NS3.CFD3.48<>21-25 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 10/23/26 | 10/29/26 | 6.2 | 6.2 |
|
170.0 |
RPL10.WP4.07200 |
RPL10.Conn NS4.CFD3.21 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] | Pull Duplex Jumper [MA<>JXSW] | Not Started | 10/23/26 | 10/27/26 | 3.8 | 3.8 |
|
156.2 |
RPL10.WP4.08600 |
RPL10.Conn NS1.CFD1.46<>45 Pull/Install Ext. Trunk (192F) [MA<>EB] | [MA<>EB] | Not Started | 10/23/26 | 10/26/26 | 2.5 | 2.5 |
|
18.8 |
RPL10.WP4.08740 |
RPL10.Conn NS2.CFD6 Pull/Install Ext. Trunk (24F) [DR<>BB] | [DR<>BB] | Not Started | 10/23/26 | 10/26/26 | 2.5 | 2.5 |
|
60.0 |
RPL10.WP4.NS3.01320 |
RPL10.Conn NS3.CFD1 Network - WBS Summary | Network | Not Started | 10/23/26 | 12/04/26 | 35.0 | 35.0 |
|
76.2 |
RPL10.WP4.NS3.01340 |
RPL10.Conn NS3.CFD1 Network Suite [JXSW<>MA] Trunks | Pre ORv3 Rack | Not Started | 10/23/26 | 10/27/26 | 3.8 | 3.8 |
|
83.8 |
RPL10.WP4.NS4.01380 |
RPL10.Conn NS4.CFD2 Network Suite [JXSW<>MA] Multi Drop Cable | Pre ORv3 Rack | Not Started | 10/23/26 | 11/03/26 | 10.0 | 10.0 |
|
73.8 |
GCD.RPL10.5365 |
L3/L4 Start - NS3 Rows 9-16 | NS | Not Started | 10/26/26 | 10/26/26 | 0.0 | 0.0 |
|
173.8 |
RPL10.CX.NS1.01190 |
RPL10.CX.NS1 - L3/L4 - Control Fault Domain 1 | NS1 Control Fault Domain 1 | Not Started | 10/26/26 | 11/17/26 | 20.0 | 20.0 |
|
21.2 |
RPL10.CX.NS3.01100 |
RPL10.CX.NS3 - L3/L4 - Elec. Domain 03/04 | NS3 ELECTRICAL | Not Started | 10/26/26 | 10/29/26 | 5.0 | 5.0 |
|
71.2 |
RPL10.CX.NS3.01280 |
RPL10.CX.NS3 - L3/L4 - Control Fault Domain 1 - TW Flush and Fill | NS3 Control Fault Domain 1 | Not Started | 10/26/26 | 11/04/26 | 10.0 | 10.0 |
|
66.2 |
RPL10.SSBC.BB.3115 |
RPL10.Ext.Build Back.SSB-Corr - LO #2 - L2 Checklist Completion and Asset Tagging | Build Back Exterior Leave Out Wall #2 (Tent Area) | Not Started | 10/26/26 | 10/30/26 | 6.2 | 6.2 |
|
42.5 |
RPL10.W3B.FE.011071 |
RPL10.Conn EF1B<>NS4.CFD4 (P2-3) Pull Fiber Trunk (288F) [EF<>JXSW] | EF1B<>NS4.4 (P2-3) [EF<>JXSW] | Not Started | 10/26/26 | 10/28/26 | 3.8 | 3.8 |
|
98.8 |
RPL10.W3B.FE.011151 |
RPL10.Conn EF2B<>NS4.CFD4 (P1-4) Pull Fiber Trunk (288F) [EF<>JXSW] | EF2B<>NS4.4 (P1-4) [EF<>JXSW] | Not Started | 10/26/26 | 10/29/26 | 5.0 | 5.0 |
|
83.8 |
RPL10.W3B.FE.011746 |
RPL10.Conn EF2F<>NS3.CFD2 (P1-4) Pull Fiber Trunk (384F) [EF<>SSW] | EF2F<>NS3.2 (P1-4) [EF<>SSW] | Not Started | 10/26/26 | 10/27/26 | 2.5 | 2.5 |
|
0.0 |
RPL10.W3B.FE.012146 |
RPL10.Conn EF2B<>NS3.CFD2 (P1-4) Install Fiber Trunk (384F) [EF<>SSW] | EF2B<>NS3.2 (P1-4) [EF<>SSW] | Not Started | 10/26/26 | 10/27/26 | 2.5 | 2.5 |
|
1.2 |
RPL10.W3B.FE.012181 |
RPL10.Conn EF2B<>NS4.CFD3 (P1-4) Install Fiber Trunk (384F) [EF<>SSW] | EF2B<>NS4.3 (P1-4) [EF<>SSW] | Not Started | 10/26/26 | 10/27/26 | 2.5 | 2.5 |
|
68.8 |
RPL10.W3B.FE.012721 |
RPL10.Conn EF2B<>NS3.CFD2 (P1-4) Test Fiber Trunk (288F) [EF<>JXSW] | EF2B<>NS3.2 (P1-4) [EF<>JXSW] | Not Started | 10/26/26 | 10/27/26 | 2.5 | 2.5 |
|
20.0 |